메뉴 건너뛰기




Volumn 4686, Issue , 2002, Pages 319-330

Clinical effectiveness of improved temporal subtraction for digital chest radiographs

Author keywords

Chest radiographs; Clinical evaluation; CR images; ROC analysis; Temporal subtraction

Indexed keywords

COMPUTERIZED TOMOGRAPHY; IMAGE ANALYSIS; PATHOLOGY; RADIOLOGY;

EID: 0036031408     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.462693     Document Type: Article
Times cited : (9)

References (9)
  • 1
    • 0031024014 scopus 로고    scopus 로고
    • Digital chest radiography: Effect of temporal subtraction images on detection accuracy
    • 11
    • Matthew C. Difazio, Heber MacMahon, Xin-Wei Xu, et al., "Digital Chest Radiography: Effect of Temporal Subtraction Images on Detection Accuracy," Radiology, vol.202, pp.447-452, 1997.11.
    • (1997) Radiology , vol.202 , pp. 447-452
    • Difazio, M.C.1    MacMahon, H.2    Xu, X.-W.3
  • 2
    • 0005094221 scopus 로고    scopus 로고
    • Clinical usefulness of temporal subtraction on digital chest radiographs
    • H. Nakata, K. Nakamura, T. Uozumi, H. Watanabe, T. Aoki, et al., "Clinical Usefulness of Temporal Subtraction on Digital Chest Radiographs," CARS2000, pp.793-797, 2000.
    • (2000) CARS2000 , pp. 793-797
    • Nakata, H.1    Nakamura, K.2    Uozumi, T.3    Watanabe, H.4    Aoki, T.5
  • 3
    • 0020603401 scopus 로고
    • Computed radiography utilizing scanning stimulated luminescence
    • M. Sonoda, M. Takano, J. Miyahara, H. Kato, "Computed Radiography Utilizing scanning stimulated luminescence", Radiology 148, 833-838, 1983.
    • (1983) Radiology , vol.148 , pp. 833-838
    • Sonoda, M.1    Takano, M.2    Miyahara, J.3    Kato, H.4
  • 4
    • 84994416825 scopus 로고    scopus 로고
    • http://xray.bsd.uchicago.edu/krl/toppage11.htm.
  • 5
    • 84893324937 scopus 로고
    • Application of digital image change detection to diagnosis and follow-up of cancer involving the lungs
    • J.H. Kinsey, B.D. Vannelli, R.S. Fontana, et al., "Application of Digital Image Change Detection to Diagnosis and Follow-up of cancer Involving the Lungs," Proc. SPIE, vol.70, pp.99-112, 1975.
    • (1975) Proc. SPIE , vol.70 , pp. 99-112
    • Kinsey, J.H.1    Vannelli, B.D.2    Fontana, R.S.3
  • 6
    • 0028218947 scopus 로고
    • Digital image subtraction of temporally sequential chest images for detection of interval change
    • 3
    • Akiko Kano, Kunio Doi, Heber MacMahon, et al., "Digital image subtraction of temporally sequential chest images for detection of interval change," Med. Phys.21, pp.453-461,1994.3.
    • (1994) Med. Phys. , vol.21 , pp. 453-461
    • Kano, A.1    Doi, K.2    MacMahon, H.3
  • 7
    • 0032764285 scopus 로고    scopus 로고
    • Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change
    • 7
    • Takayuki Ishida, Shigehiko Katsuragawa, Katsumi Nakamura, Heber MacMahon, Kunio Doi, "Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change," Med. Phys.26, pp.1320-1329, 1999.7.
    • (1999) Med. Phys. , vol.26 , pp. 1320-1329
    • Ishida, T.1    Katsuragawa, S.2    Nakamura, K.3    MacMahon, H.4    Doi, K.5
  • 8
    • 0024053929 scopus 로고    scopus 로고
    • Complete discrete 2-D Gabor transforms by neural networks for image analysis and compression
    • 7
    • John G. Daugman, "Complete discrete 2-D Gabor Transforms by Neural Networks for Image Analysis and Compression," IEEE Trans. on ASSP. vol.36, pp. 1169-1179, 1998.7.
    • (1998) IEEE Trans. On ASSP , vol.36 , pp. 1169-1179
    • Daugman, J.G.1
  • 9
    • 0005035936 scopus 로고
    • ROC kaiseki no kiso to ouyou
    • Japan
    • Japanese Society of Radiological Technology, ROC Kaiseki no Kiso to Ouyou, JSRT, Japan, 1994.
    • (1994) JSRT


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.