메뉴 건너뛰기




Volumn 4687, Issue , 2002, Pages 1-12

Comparison between different encoding schemes for synthetic aperture imaging

Author keywords

Coding; Focusing; Imaging; Spatial coding; Synthetic aperture; Temporal coding; Ultrasound

Indexed keywords

FREQUENCY MODULATION; IMAGE ANALYSIS; IMAGE CODING; SIGNAL TO NOISE RATIO;

EID: 0036030695     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.462151     Document Type: Conference Paper
Times cited : (31)

References (20)
  • 1
    • 0019902876 scopus 로고
    • A real-time synthetic aperture digital acoustic imaging system
    • P. Alais and A.F. Metherell, eds.
    • S. Bennett, D.K. Peterson, D. Corl, and G.S. Kino, "A real-time synthetic aperture digital acoustic imaging system," in Acoust. Imaging, P. Alais and A.F. Metherell, eds., 10, pp. 669-692, 1982.
    • (1982) Acoust. Imaging , vol.10 , pp. 669-692
    • Bennett, S.1    Peterson, D.K.2    Corl, D.3    Kino, G.S.4
  • 3
    • 84942213276 scopus 로고
    • Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part I: Basic principles
    • L.F. Nock and G.E. Trahey, "Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part i: basic principles," IEEE Trans. Ultrason., Ferroelec., Freq. Contr. 39, pp. 489-495, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.39 , pp. 489-495
    • Nock, L.F.1    Trahey, G.E.2
  • 4
    • 0000474501 scopus 로고
    • Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part II: Effects of and correction for motion
    • L.F. Nock and G.E. Trahey, "Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - part II: effects of and correction for motion," IEEE Trans. Ultrason., Ferroelec., Freq. Contr. 39, pp. 496-501, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.39 , pp. 496-501
    • Nock, L.F.1    Trahey, G.E.2
  • 5
    • 0026868890 scopus 로고
    • Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging
    • M. O'Donnell and L.J. Thomas, "Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging," IEEE Trans. Ultrason., Ferroelec., Freq. Contr. 39, pp. 366-380, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.39 , pp. 366-380
    • O'Donnell, M.1    Thomas, L.J.2
  • 6
    • 0033294970 scopus 로고    scopus 로고
    • Experimental study of transmit synthetic focusing combined with receive dynamic focusing in B-mode ultrasound imaging systems
    • M.H. Bae, M.K. Jeong, T.K. Song, and Y.B. Ahn, "Experimental study of transmit synthetic focusing combined with receive dynamic focusing in B-mode ultrasound imaging systems," in Proc. IEEE Ultrason. Symp., pp. 1261-1264, 1999.
    • (1999) Proc. IEEE Ultrason. Symp. , pp. 1261-1264
    • Bae, M.H.1    Jeong, M.K.2    Song, T.K.3    Ahn, Y.B.4
  • 9
    • 0035728931 scopus 로고    scopus 로고
    • Velocity estimation using synthetic aperture imaging
    • p. to be published
    • S. Nikolov and J.A. Jensen, "Velocity estimation using synthetic aperture imaging," in Proc. IEEE Ultrason. Symp., p. to be published, 2001.
    • (2001) Proc. IEEE Ultrason. Symp.
    • Nikolov, S.1    Jensen, J.A.2
  • 11
    • 0030197653 scopus 로고    scopus 로고
    • On the signal-to-noise ratio of a synthetic aperture ultrasound imaging method
    • J.T. Ylitalo, "On the signal-to-noise ratio of a synthetic aperture ultrasound imaging method," Eur. J. Ultrasound, pp. 277-281, 1996.
    • (1996) Eur. J. Ultrasound , pp. 277-281
    • Ylitalo, J.T.1
  • 12
    • 0034580046 scopus 로고    scopus 로고
    • Velocity estimation using recursive ultrasound imaging and spatially encoded signals
    • S.I. Nikolov, K. Gammelmark, and J.A. Jensen, "Velocity estimation using recursive ultrasound imaging and spatially encoded signals," in Proc. IEEE Ultrason. Symp., 2, pp. 1473-1477, 2000.
    • (2000) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1473-1477
    • Nikolov, S.I.1    Gammelmark, K.2    Jensen, J.A.3
  • 13
    • 0034579635 scopus 로고    scopus 로고
    • Clinical use and evaluation of coded excitation in B-mode images
    • T.X. Misaridis, M.H. Pedersen, and J.A. Jensen, "Clinical use and evaluation of coded excitation in B-mode images," in Proc. IEEE Ultrason. Symp., 2, pp. 1689-1693, 2000.
    • (2000) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1689-1693
    • Misaridis, T.X.1    Pedersen, M.H.2    Jensen, J.A.3
  • 15
    • 0034579628 scopus 로고    scopus 로고
    • Synthetic transmit aperture using orthogonal golay coded excitation
    • R.Y. Chiao and L.J. Thomas, "Synthetic transmit aperture using orthogonal golay coded excitation," in Proc. IEEE Ultrason. Symp., pp. 1677-1680, 2000.
    • (2000) Proc. IEEE Ultrason. Symp. , pp. 1677-1680
    • Chiao, R.Y.1    Thomas, L.J.2
  • 17
  • 20
    • 0003607019 scopus 로고    scopus 로고
    • PhD thesis, Ørsted• DTU, Technical University of Denmark, Lyngby, Denmark
    • T. Misaridis, Ultrasound imaging using coded signals. PhD thesis, Ørsted• DTU, Technical University of Denmark, Lyngby, Denmark, 2001.
    • (2001) Ultrasound imaging using coded signals
    • Misaridis, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.