메뉴 건너뛰기




Volumn 4684 II, Issue , 2002, Pages 1002-1009

Quantitative study of renormalization transformation method to correct the inhomogeneity in MR images

Author keywords

Image Filter; Image Segmentation; Inhomogeneity; MR images; Renormalization Transformation

Indexed keywords

BRAIN; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; MATHEMATICAL TRANSFORMATIONS; OPTICAL FILTERS;

EID: 0036028245     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.467055     Document Type: Conference Paper
Times cited : (12)

References (6)
  • 1
    • 0023064533 scopus 로고
    • Image nonuniformity in magnetic resonance imaging: Its magnitude and methods for its correction
    • B.R. Condon, J. Patterson, and D. Wyper, "Image nonuniformity in magnetic resonance imaging: Its magnitude and methods for its correction:, Br. J. Radiol., vol. 60, pp 83-87, (1987).
    • (1987) Br. J. Radiol. , vol.60 , pp. 83-87
    • Condon, B.R.1    Patterson, J.2    Wyper, D.3
  • 2
    • 0027193859 scopus 로고
    • Correction of intensity nonuniformity in MR images of any orientation
    • D.A.G. Wicks, G.J. Barker, and P.S. Tofts, "Correction of intensity nonuniformity in MR images of any orientation", Magn. Reson. Imaging Vol. 11, pp. 183-196 (1993).
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 183-196
    • Wicks, D.A.G.1    Barker, G.J.2    Tofts, P.S.3
  • 3
    • 0028339167 scopus 로고
    • Sources of intensity nonuniformity in spin echo images at 1.5 T
    • A. Simmons, P.S. Tofts, G.J. Barker, and S.R. Arridge, "Sources of intensity nonuniformity in spin echo images at 1.5 T", MRM 32 pp 121-128, (1994).
    • (1994) MRM , vol.32 , pp. 121-128
    • Simmons, A.1    Tofts, P.S.2    Barker, G.J.3    Arridge, S.R.4
  • 4
    • 0023125860 scopus 로고
    • Intensity correction in surface-coil MR imaging
    • L. Axel, J. Costantini, and J. Listerrud, "Intensity correction in surface-coil MR imaging", AJR, 148, pp 418-420, (1987).
    • (1987) AJR , vol.148 , pp. 418-420
    • Axel, L.1    Costantini, J.2    Listerrud, J.3
  • 5
    • 0032034233 scopus 로고    scopus 로고
    • Optimized homomorphis unsharp masking for MR grayscale inhomogeneity correction
    • B.H. Brinkmann, A. Manduca, and R.A. Robb, "Optimized homomorphis unsharp masking for MR grayscale inhomogeneity correction", IEEE. Trans. Med. Imag., vol. 17(2), pp 161-171 (1998).
    • (1998) IEEE. Trans. Med. Imag. , vol.17 , Issue.2 , pp. 161-171
    • Brinkmann, B.H.1    Manduca, A.2    Robb, R.A.3
  • 6
    • 0034839394 scopus 로고    scopus 로고
    • A renormalization method for inhomogeneity correction of MR images
    • D. Chen, L. Li, D. Yoon, J.H. Lee and Z. Liang, "A renormalization method for inhomogeneity correction of MR images", Proceedings of SPIE Vol. 4322 pp 939-942 (2001).
    • (2001) Proceedings of SPIE , vol.4322 , pp. 939-942
    • Chen, D.1    Li, L.2    Yoon, D.3    Lee, J.H.4    Liang, Z.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.