메뉴 건너뛰기




Volumn 29, Issue 5, 2002, Pages 857-868

Comparison of high-energy photon and electron dosimetry for various dosimetry protocols

Author keywords

Clinical reference dosimetry; IAEA TRS 277 protocol; IAEA TRS 398 protocol; JARP protocol; TG 51 protocol

Indexed keywords

WATER; COBALT 60;

EID: 0035999416     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1470208     Document Type: Article
Times cited : (16)

References (29)
  • 1
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • (1999) Med. Phys , vol.26 , pp. 1847-1870
  • 3
    • 85008322717 scopus 로고
    • A practical code for the dosimetry of high-energy photon and electron beams in radiotheraphy
    • Tokyo, (in Japanese)
    • (1986) Tsusho-sangyo-kenkyusya
  • 4
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • (1983) Med. Phys , vol.10 , pp. 741-771
  • 8
    • 0027535624 scopus 로고
    • Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams
    • (1993) Phys. Med. Biol , vol.38 , pp. 267-290
    • Ma, C.M.1    Nahum, A.E.2
  • 12
    • 0035143114 scopus 로고    scopus 로고
    • Reference dosimetry in clinical high-energy photon beams: Comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    • (2001) Med. Phys , vol.28 , pp. 46-54
    • Huq, M.S.1    Andreo, P.2
  • 14
    • 0034104705 scopus 로고    scopus 로고
    • Comment on 'AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • Med. Phys. 26, 1847-1870 (1999)
    • (2000) Med. Phys , vol.27 , pp. 445-447
    • Khan, F.M.1
  • 19
  • 21
    • 33744692400 scopus 로고    scopus 로고
    • Implementation of TG-51: Practical considerations and why use TG-51 instead of TG-21
    • (2001) AAPM Newsletter , vol.26 , pp. 21-22
    • Shackford, H.1
  • 25
    • 0000405320 scopus 로고
    • Improved calculations of stopping power ratios and their correlation with the quality of therapeutic photon beams
    • (Proc. Symp. Vienna, 1993) (IAEA, Vienna)
    • (1994) Measurement Assurance in Dosimetry , pp. 335-359
    • Andreo, P.1
  • 29
    • 0018823003 scopus 로고
    • Procedures in external radiation therapy dosimetry with electron and photon beams with maximum energies between 1 and 50 MeV
    • (1980) Acta Radiol.: Oncol , vol.19 , pp. 55-79


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.