메뉴 건너뛰기




Volumn 54, Issue 3, 2001, Pages 407-411

Replacement of segmental bone defects using porous bioceramic cylinders: A biomechanical and x-ray diffraction study

Author keywords

Porous ceramics; Replacement of bone defects; Segmental bone defects

Indexed keywords

BIOMECHANICS; CALCIUM COMPOUNDS; CERAMIC MATERIALS; JOINTS (ANATOMY); PHOSPHATES; POROUS MATERIALS; TRANSPLANTATION (SURGICAL); X RAY DIFFRACTION ANALYSIS;

EID: 0035809841     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/1097-4636(20010305)54:3<407::AID-JBM140>3.0.CO;2-C     Document Type: Article
Times cited : (44)

References (18)
  • 9
    • 0029655796 scopus 로고    scopus 로고
    • Osteoinduction in porous hydroxyapatite implanted in heterotopic sites of different animal models
    • (1996) Biomaterials , vol.17 , pp. 31-35
    • Ripamonti, U.1
  • 14
    • 0019447856 scopus 로고
    • Calcium phosphate ceramics as hard tissue prosthetics
    • (1981) Clin Orthop , vol.157 , pp. 259-278
    • Jarcho, M.1
  • 17
    • 0020282960 scopus 로고
    • Extraskeletal implantation of a porous hydroxyapatite ceramic
    • (1982) J Dent Res , vol.61 , pp. 1458-1460
    • Piecuch, J.F.1