메뉴 건너뛰기




Volumn 1, Issue SUMMER, 2001, Pages 689-693

An automatic voltage sag detector using a discrete wavelet transform and a CFAR detector

Author keywords

CFAR detector; Power quality; Voltage sags; Wavelet transforms

Indexed keywords

ALGORITHMS; CALCULATIONS; DATA STRUCTURES; ELECTRIC LINES; FIR FILTERS; PROBABILITY DENSITY FUNCTION; RELIABILITY; WAVELET TRANSFORMS;

EID: 0035792205     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 0002953305 scopus 로고
    • Solving problems of power quality
    • Dec.
    • J. Douglas, "Solving problems of power quality," EPRI Journal, vol. 18, pp. 6-15, Dec. 1993.
    • (1993) EPRI Journal , vol.18 , pp. 6-15
    • Douglas, J.1
  • 2
    • 0013332525 scopus 로고    scopus 로고
    • Waveform characteristics of voltage sags: Statistical analysis
    • Electrotek Concepts, Inc.; EPRI report WO5461, Dec.
    • Electrotek Concepts, Inc., "Waveform characteristics of voltage sags: statistical analysis," EPRI report WO5461, Dec. 1998.
    • (1998)
  • 3
    • 4243359610 scopus 로고    scopus 로고
    • Recommended practice on power quality event characterization
    • IEEE P1159.2; Draft of IEEE Working Group on Monitoring Electric Power Quality of SCC22 - Power Quality; Dec.
    • IEEE P1159.2, "Recommended practice on power quality event characterization," Draft of IEEE Working Group on Monitoring Electric Power Quality of SCC22 - Power Quality, Dec. 1998.
    • (1998)
  • 4
    • 0032660808 scopus 로고    scopus 로고
    • A wavelet-based procedure for the automatically determining the beginning and end of transmission system voltage sags
    • 31 Jan.-4 Feb.
    • A. Parsons, W. M. Grady, and E. J. Powers, "A wavelet-based procedure for the automatically determining the beginning and end of transmission system voltage sags," Proc. of IEEE PES 1999 Winter Meeting, New York, NY, pp. 1310-1315, 31 Jan.-4 Feb. 1999.
    • (1999) Proc. of IEEE PES 1999 Winter Meeting, New York, NY , pp. 1310-1315
    • Parsons, A.1    Grady, W.M.2    Powers, E.J.3
  • 5
    • 0028699985 scopus 로고
    • Electric power quality disturbance detection using wavelet transform analysis
    • Oct.
    • S. Santoso, E. J. Powers, and W. M. Grady, "Electric power quality disturbance detection using wavelet transform analysis," Proc. of IEEE TFTS 1994, Philadelphia, PA, pp. 166-169, Oct. 1994.
    • (1994) Proc. of IEEE TFTS 1994, Philadelphia, PA , pp. 166-169
    • Santoso, S.1    Powers, E.J.2    Grady, W.M.3
  • 8
    • 0003542950 scopus 로고
    • Detection of signals in noise
    • New York: Academic press
    • A. D. Ahallen, Detection of signals in noise. New York: Academic press, 1971.
    • (1971)
    • Ahallen, A.D.1
  • 9
    • 0028463002 scopus 로고
    • Optimality of the cell average CFAR detector
    • July
    • P. P. Gandhi and S. A. Kassam, "Optimality of the cell average CFAR detector," IEEE Trans. on Info. Theory, vol. 40, pp. 1226-1228, July 1994.
    • (1994) IEEE Trans. on Info. Theory , vol.40 , pp. 1226-1228
    • Gandhi, P.P.1    Kassam, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.