메뉴 건너뛰기




Volumn 4587, Issue , 2001, Pages 350-360

High-frequency wirebonding: Its impact on bonding machine parameters and MCM substrate bondability

Author keywords

Bonding machine setup; High frequency wirebonding; MCM wirebonds; Statistical analysis of wirebonding results; Wirebond reliability; Wirebond testing

Indexed keywords

BOND STRENGTH (MATERIALS); BONDING; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; METALLIZING; NATURAL FREQUENCIES; SUBSTRATES; TRANSDUCERS; ULTRASONIC EFFECTS; WAVEFORM ANALYSIS;

EID: 0035772474     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (33)
  • 2
    • 0001616177 scopus 로고
    • Electronic materials and packaging structures for multichip modules
    • H.K. Charles, Jr., "Electronic Materials and Packaging Structures for Multichip Modules," Journal of Electronic Packaging, Vol. 11, No. 2, pp. 226-233, 1992.
    • (1992) Journal of Electronic Packaging , vol.11 , Issue.2 , pp. 226-233
    • Charles H.K., Jr.1
  • 5
    • 0009599717 scopus 로고    scopus 로고
    • Test methods for destructive shear testing of ball bonds
    • ASTM Standard Test Method F1269-89(1995)el, West Conshohocken, Pennsylvania
    • ASTM Standard Test Method F1269-89(1995)el, "Test Methods for Destructive Shear Testing of Ball Bonds," Annual Book of ASTM Standards, West Conshohocken, Pennsylvania, 1997.
    • (1997) Annual Book of ASTM Standards
  • 6
    • 0006936144 scopus 로고    scopus 로고
    • Standard test methods for measuring pull strength of microelectronic wire bonds
    • ASTM Standard Test Method F7459-84(1995)el, West Conshohocken, Pennsylvania
    • ASTM Standard Test Method F7459-84(1995)el, "Standard Test Methods for Measuring Pull Strength of Microelectronic Wire Bonds," Annual Book of ASTM Standards, West Conshohocken, Pennsylvania, 1997.
    • (1997) Annual Book of ASTM Standards
  • 8
  • 9
    • 84932197883 scopus 로고
    • Effects of ultrasound on deformation characteristics of metals
    • B. Langenecker, "Effects of Ultrasound on Deformation Characteristics of Metals," IEEE Transactions on Sonics and Ultrasonics, Vol. SU-13, pp. 1-8, 1966.
    • (1966) IEEE Transactions on Sonics and Ultrasonics , vol.SU-13 , pp. 1-8
    • Langenecker, B.1
  • 10
    • 0001888432 scopus 로고
    • The effect of ultrasonic frequency on intermetallic reactivity of Au-Al bonds
    • December
    • T.H. Ramsey and C. Alfaro, "The Effect of Ultrasonic Frequency on Intermetallic Reactivity of Au-Al Bonds," Solid State Technology, Vol. 34, pp. 37-38, December 1991.
    • (1991) Solid State Technology , vol.34 , pp. 37-38
    • Ramsey, T.H.1    Alfaro, C.2
  • 13
    • 0000740861 scopus 로고
    • Room temperature ball bonding using high ultrasonic frequencies
    • Singapore, May
    • V.P. Jaecklin, "Room Temperature Ball Bonding Using High Ultrasonic Frequencies," Proc. Semicon: Test, Assembly and Packaging, Singapore, pp. 208-214, May 1995.
    • (1995) Proc. Semicon: Test, Assembly and Packaging , pp. 208-214
    • Jaecklin, V.P.1
  • 17
    • 0011046662 scopus 로고    scopus 로고
    • Consolidated Vacuum Corporation (CVC) is now owned by Veeco Instruments, Inc., Terminal Drive, Plainview, New York 11803, (516) 349-8300
    • Consolidated Vacuum Corporation (CVC) is now owned by Veeco Instruments, Inc., Termyinal Drive, Plainview, New York 11803, (516) 349-8300.
  • 18
    • 0011033755 scopus 로고    scopus 로고
    • Marpet Enterprises, Inc., 44 Garden Street, Danvers, Massachusetts 01923, (978) 777-7773.
    • Marpet Enterprises, Inc., 44 Garden Street, Danvers, Massachusetts 01923, (978) 777-7773.
  • 19
    • 0010992654 scopus 로고    scopus 로고
    • UTHE Technologies, Inc., 252 Great Mall Parkway, Milpitas, California 95035, (408) 945-8843
    • UTHE Technologies, Inc., 252 Great Mall Parkway, Milpitas, California 95035, (408) 945-8843.
  • 22
    • 0010997936 scopus 로고    scopus 로고
    • 1330 Clegg Street, Petaluma, California 94954, (707) 765-4545
    • SPT-Roth-Small Precision Tools, 1330 Clegg Street, Petaluma, California 94954, (707) 765-4545.
    • SPT-Roth-Small Precision Tools
  • 23
    • 0011036898 scopus 로고    scopus 로고
    • 2978 Main Street, Buffalo, New York 14214, (716) 837-1000
    • Williams Advanced Materials, 2978 Main Street, Buffalo, New York 14214, (716) 837-1000.
    • Williams Advanced Materials
  • 24
    • 0002148069 scopus 로고
    • A new test for thermocompression bonds
    • J.A. Arleth and R.D. Demensus, "A New Test for Thermocompression Bonds," Electronic Products, Vol. 9, pp. 92-94, 1967.
    • (1967) Electronic Products , vol.9 , pp. 92-94
    • Arleth, J.A.1    Demensus, R.D.2
  • 25
    • 0020914505 scopus 로고
    • The microelectronic ball bond shear test - A critical review and comprehensive guide to its use
    • G.G. Harman, "The Microelectronic Ball Bond Shear Test - A Critical Review and Comprehensive Guide to its Use," International Journal of Hybrid Microelectronics, Vol. 6, No. 1, pp. 127-141, 1983.
    • (1983) International Journal of Hybrid Microelectronics , vol.6 , Issue.1 , pp. 127-141
    • Harman, G.G.1
  • 26
    • 0022949029 scopus 로고
    • Ball bond shearing: An interlaboratory comparison
    • Atlanta, Georgia, October 6-9
    • H.K. Charles, Jr., "Ball Bond Shearing: An Interlaboratory Comparison," Proc. 1986 International Microelectronics Symposium, Atlanta, Georgia, October 6-9, pp. 265-274, 1986.
    • (1986) Proc. 1986 International Microelectronics Symposium , pp. 265-274
    • Charles H.K., Jr.1
  • 27
    • 0011028593 scopus 로고    scopus 로고
    • Dage Precision Industries, Inc., 4024 Clipper Court, Fremont, California 94938, (510) 683-3930
    • Dage Precision Industries, Inc., 4024 Clipper Court, Fremont, California 94938, (510) 683-3930.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.