메뉴 건너뛰기




Volumn 4491, Issue , 2001, Pages 41-51

Surface landmine and trip wire detection using calibrated polarization measurements in the LWIR and SWIR

Author keywords

Infrared; Landmine detection; Polarization; Thermovision 900; Trip wire

Indexed keywords

CALIBRATION; CAMERAS; ELECTRIC FILTERS; ELECTROMAGNETIC WAVE POLARIZATION; IMAGE ANALYSIS; INFRARED RADIATION; MATHEMATICAL MODELS; MATHEMATICAL TRANSFORMATIONS;

EID: 0035767562     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.450185     Document Type: Conference Paper
Times cited : (16)

References (7)
  • 1
    • 0003623862 scopus 로고    scopus 로고
    • Polarization properties in the IR region of painted surfaces and rough Al surfaces
    • FOA-R-00-01646-615-SE, nov.
    • G. Forssell, T. Hallberg, Polarization properties in the IR region of painted surfaces and rough Al surfaces, FOA-R-00-01646-615-SE, nov. 2000.
    • (2000)
    • Forssell, G.1    Hallberg, T.2
  • 2
    • 0033686267 scopus 로고    scopus 로고
    • Towards an operational sensor-fusion system for anti-personnel landmine detection
    • April
    • F. Cremer, et al, Towards an operational sensor-fusion system for anti-personnel landmine detection, SPIE Vol 4038, p. 792, April 2000.
    • (2000) SPIE , vol.4038 , pp. 792
    • Cremer, F.1
  • 3
    • 0033713624 scopus 로고    scopus 로고
    • Trip wire detection using polarimetric IR
    • April
    • J. Storm, T. Geisler, Trip wire detection using polarimetric IR, SPIE, Vol. 4038, April 2000.
    • (2000) SPIE , vol.4038
    • Storm, J.1    Geisler, T.2
  • 4
    • 0004269369 scopus 로고
    • Polarized light
    • M. Dekker Inc., New York
    • E. Collett, Polarized light. M. Dekker Inc., New York, 1993.
    • (1993)
    • Collett, E.1
  • 5
    • 0010806904 scopus 로고    scopus 로고
    • Calibrated sensitive polarization measurement methods in the regions 3-5 μm and 8-12 μm, corrected for contributions to the detector signal from the polarizer
    • San Diego; to be published
    • G. Forssell, T. Hallberg, Calibrated sensitive polarization measurement methods in the regions 3-5 μm and 8-12 μm, corrected for contributions to the detector signal from the polarizer, SPIE Vol. 4491, San Diego, 2001, to be published.
    • (2001) SPIE , vol.4491
    • Forssell, G.1    Hallberg, T.2
  • 6
    • 0032664814 scopus 로고    scopus 로고
    • Infrared polarimetric camera system development
    • April
    • H. Barnes, M. Jones and P. Bishop, Infrared polarimetric camera system development, SPIE, Vol. 3710, April 1999.
    • (1999) SPIE , vol.3710
    • Barnes, H.1    Jones, M.2    Bishop, P.3
  • 7
    • 0010809698 scopus 로고    scopus 로고
    • Measurement equipment at the department of IR Systems
    • editor C. Nelsson and P. Nilsson, FOA-R-99-01111-615-SE, april
    • Measurement equipment at the department of IR Systems, editor C. Nelsson and P. Nilsson, FOA-R-99-01111-615-SE, april 1999.
    • (1999)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.