메뉴 건너뛰기




Volumn 4504, Issue , 2001, Pages 159-167

A novel x-ray tube with a line filament

Author keywords

Filament; Line focus; Monte Carlo calculation; X ray pinhole camera; X ray tube

Indexed keywords

ANODES; CATHODES; CHARGE COUPLED DEVICES; ELECTRIC FIELDS; ELECTRON EMISSION; MAGNETIC FIELDS; MONTE CARLO METHODS; RADIATION DETECTORS; THERMAL CONDUCTIVITY OF SOLIDS; X RAY CAMERAS;

EID: 0035767182     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.448462     Document Type: Article
Times cited : (4)

References (3)
  • 2
    • 4244086773 scopus 로고
    • Doppler-broadening measurements of x-ray lines for determination of the ion temperature in tokamak plasmas
    • M. Bitter, S. von Goeler, R. Horton, M. Goldman, K.W. Hill, N.R. Sauthoff, and W. Stodiek, "Doppler-broadening measurements of x-ray lines for determination of the ion temperature in tokamak plasmas", Phy. Rev. Lett. 42, 304-307 1979.
    • (1979) Phy. Rev. Lett. , vol.42 , pp. 304-307
    • Bitter, M.1    Von Goeler, S.2    Horton, R.3    Goldman, M.4    Hill, K.W.5    Sauthoff, N.R.6    Stodiek, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.