메뉴 건너뛰기




Volumn 4508, Issue , 2001, Pages 134-140

Development of a CdZnTe-based small field of view gamma camera

Author keywords

ASIC; CdZnTe; Energy resolution; Gamma camera; Photopeak efficiency; Small Field of View

Indexed keywords

APPLICATION SPECIFIC INTEGRATED CIRCUITS; GAMMA RAYS; NUCLEAR MEDICINE; RADIATION DETECTORS; SEMICONDUCTING CADMIUM COMPOUNDS;

EID: 0035762633     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.450791     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 0010768084 scopus 로고    scopus 로고
    • CZT detector for dual energy x-ray absorptiometry (DEXA)
    • J. Wear et al., "CZT detector for dual energy x-ray absorptiometry (DEXA), presented at the 1999 SPIE Annual Meeting.
    • (1999) SPIE Annual Meeting
    • Wear, J.1
  • 2
    • 0035250851 scopus 로고    scopus 로고
    • Intraoperative detection of radiolabeled compounds using a hand-held gamma probe
    • M. Ricard, "Intraoperative detection of radiolabeled compounds using a hand-held gamma probe", NIM A, 458, 26-33, 2001.
    • (2001) NIM A , vol.458 , pp. 26-33
    • Ricard, M.1
  • 4
    • 0010835474 scopus 로고    scopus 로고
    • Y. Eisen et al, NIM A, 380, 474, 1996.
    • (1996) NIM A , vol.380 , pp. 474
    • Eisen, Y.1
  • 5
    • 0035250737 scopus 로고    scopus 로고
    • A new design for a high resolution, high efficiency CZT gamma camera
    • C. Mestais et al, :"A new design for a high resolution, high efficiency CZT gamma camera", NIM A, 458, 62-67, 2001.
    • (2001) NIM A , vol.458 , pp. 62-67
    • Mestais, C.1
  • 6
    • 0034594105 scopus 로고    scopus 로고
    • Tomographic small animal imaging using a high-resolution semi-conductor camera
    • G.A. Kastis et al, "Tomographic small animal imaging using a high-resolution semi-conductor camera", IEEE/NSS Symposium Conference record, 21-31, 2000.
    • (2000) IEEE/NSS Symposium Conference record , pp. 21-31
    • Kastis, G.A.1
  • 7
    • 0035250743 scopus 로고    scopus 로고
    • Medical applications of CdTe and CdZnTe detectors
    • C. Scheiber et al, "Medical Applications of CdTe and CdZnTe detectors", NIM A, 458, 12-25, 2001.
    • (2001) NIM A , vol.458 , pp. 12-25
    • Scheiber, C.1
  • 8
    • 0013125502 scopus 로고    scopus 로고
    • Design of combined x-ray CT and Spect systems for small animals
    • K. Iwata et al, Design of combined x-ray CT and Spect systems for small animals", IEEE/NSS Symposium Conference record, 1999.
    • (1999) IEEE/NSS Symposium Conference record
    • Iwata, K.1
  • 10
    • 0034594097 scopus 로고    scopus 로고
    • A combined scintimammography / Stereotactic core biopsy digital X-ray system
    • Lyon, France; October 15-20
    • A.G. Weisenberger et al., "A Combined Scintimammography / Stereotactic Core Biopsy Digital X-ray System", presented at the IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyon, France; October 15-20, 2000.
    • (2000) IEEE Nuclear Science Symposium and Medical Imaging Conference
    • Weisenberger, A.G.1
  • 11
    • 0034593899 scopus 로고    scopus 로고
    • Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantoms
    • Lyon, France; October 15-20, to be published in the IEEE Transactions on Nuclear Science, and references therein
    • S. Majewski et al., "Optimization of Dedicated Scintimammography Procedure Using Detector Prototypes and Compressible Phantoms", presented at the IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyon, France; October 15-20, 2000, to be published in the IEEE Transactions on Nuclear Science, 2001, and references therein.
    • (2000) IEEE Nuclear Science Symposium and Medical Imaging Conference
    • Majewski, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.