-
1
-
-
0019435541
-
Osseointegrated titanium implants. Requirements for ensuring a long‐lasting, direct bone‐to‐implant anchorage in man
-
1 Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long‐lasting, direct bone‐to‐implant anchorage in man. Acta Orthop Scand 1981 ; 52: 155–170.
-
(1981)
Acta Orthop Scand
, vol.52
, pp. 155-170
-
-
Albrektsson, T1
Branemark, PI2
Hansson, HA3
Lindstrom, J4
-
2
-
-
0002455249
-
Bone tissue response, in: Tissue‐integrated prosthesis: osseointegration in clinical dentistry
-
2 Albrektsson T. Bone tissue response. In: Branemark P‐I, Zarb GA, Albrektsson T, eds. Tissue‐integrated prosthesis: osseointegration in clinical dentistry. Chicago: Quintessence, 1985: 129–143.
-
(1985)
, pp. 129-143
-
-
Albrektsson, T1
-
3
-
-
0002611019
-
Osseointegration: a requiem for the periodontal ligament
-
3 Zarb GA, Albrektsson T. Osseointegration: a requiem for the periodontal ligament Intn Periodontics Restorative Dent 1991 ; 11: 88–91.
-
(1991)
Intn Periodontics Restorative Dent
, vol.11
, pp. 88-91
-
-
Zarb, GA1
Albrektsson, T2
-
4
-
-
0013093214
-
Corrosion of metallic implants and prosthetic devices, in: Metals handbook
-
4 Fraker AC. Corrosion of metallic implants and prosthetic devices. In: Metals handbook. 9th Ed. Vol. 13. Metals Park, OH: American Society for Metals (ASM) International, 1987: 1324–1335.
-
(1987)
, pp. 1324-1335
-
-
Fraker, AC1
-
5
-
-
0023384583
-
The electrochemical behavior of metallic implant materials as an indicator of their biocom‐patibility
-
5 Zitter H, Plenk H Jr. The electrochemical behavior of metallic implant materials as an indicator of their biocom‐patibility. J Biomed Mater Res 1987 ; 21: 881–896.
-
(1987)
J Biomed Mater Res
, vol.21
, pp. 881-896
-
-
Zitter, H1
Plenk, H2
-
6
-
-
0003993333
-
The biomaterial‐tissue interface and its analogues in surface science and technology, in: The bone‐biomaterial interface
-
6 Kasemo B, Lausmaa J. The biomaterial‐tissue interface and its analogues in surface science and technology. In: Davies JE, ed. The bone‐biomaterial interface. Toronto: University of Toronto Press, 1991: 19–32.
-
(1991)
, pp. 19-32
-
-
Kasemo, B1
Lausmaa, J2
-
7
-
-
0000174683
-
Corrosion of titanium and titanium alloys, in: Metals handbook
-
7 Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. In: Metals handbook. 9th Ed. Vol. 13. Metals Park, OH: American Society for Metals (ASM) International, 1987: 669–706.
-
(1987)
, pp. 669-706
-
-
Schutz, RW1
Thomas, DE2
-
8
-
-
0025414641
-
Surface spectroscopic characterization of titanium implant materials
-
8 Lausmaa J, Kasemo B, Mattsson H. Surface spectroscopic characterization of titanium implant materials. Appi Surface Sci 1990 ; 44: 133–146.
-
(1990)
Appi Surface Sci
, vol.44
, pp. 133-146
-
-
Lausmaa, J1
Kasemo, B2
Mattsson, H3
-
9
-
-
0032013713
-
Spectroscopic studies of three osseointegrated implants
-
9 Sawase T, Hai K, Yoshida K, Bab K, Hatada R, Atsuta M. Spectroscopic studies of three osseointegrated implants. J Dent 1998 ; 26: 119–124.
-
(1998)
J Dent
, vol.26
, pp. 119-124
-
-
Sawase, T1
Hai, K2
Yoshida, K3
Bab, K4
Hatada, R5
Atsuta, M6
-
10
-
-
0021120213
-
Metal ion release from titanium‐based prosthetic segmentai replacements of long bones in baboons: a long‐term study
-
10 Woodman JL, Jacobs JJ, Galante JO, Urban RM. Metal ion release from titanium‐based prosthetic segmentai replacements of long bones in baboons: a long‐term study. J Orthop Res 1984 ; 1: 421–430.
-
(1984)
J Orthop Res
, vol.1
, pp. 421-430
-
-
Woodman, JL1
Jacobs, JJ2
Galante, JO3
Urban, RM4
-
11
-
-
0001882691
-
The release of titanium into human bone from a titanium implant coated with plasma‐sprayed titanium, in: Clinical implant materials: advances in biomaterials. Vol. 9
-
11 Osborn JF, Willich P, Meenen N. The release of titanium into human bone from a titanium implant coated with plasma‐sprayed titanium. In: Heimke G, Soltesz U, Lee AJC, eds. Clinical implant materials: advances in biomaterials. Vol. 9. Amsterdam: Elsevier, 1990: 75–80.
-
(1990)
, pp. 75-80
-
-
Osborn, JF1
Willich, P2
Meenen, N3
-
12
-
-
0025642771
-
Secondary ion mass spectrometry in the study of biomineralizations and biomaterials
-
12 Lodding AR, Fischer PM, Odelius HA, et al. Secondary ion mass spectrometry in the study of biomineralizations and biomaterials. Analytica Chimica Acta 1990 ; 241: 299–314.
-
(1990)
Analytica Chimica Acta
, vol.241
, pp. 299-314
-
-
Lodding, AR1
Fischer, PM2
Odelius, HA3
-
13
-
-
0018449066
-
In vitro corrosion testing of titanium surgical implant alloys: an approach to understanding titanium release from implants
-
13 Solar RJ, Pollack SR, Korostoff E. In vitro corrosion testing of titanium surgical implant alloys: an approach to understanding titanium release from implants. J Biomed Mater Res 1979 ; 13: 217–250.
-
(1979)
J Biomed Mater Res
, vol.13
, pp. 217-250
-
-
Solar, RJ1
Pollack, SR2
Korostoff, E3
-
14
-
-
0002560938
-
Application of micro beam PIXE to detection of titanium ion release from dental and orthopaedic implants
-
14 Ektessabi AM, Otsuka T, Tsuboi Y, et al. Application of micro beam PIXE to detection of titanium ion release from dental and orthopaedic implants. Int J PIXE 1994 ; 4: 81–91.
-
(1994)
Int J PIXE
, vol.4
, pp. 81-91
-
-
Ektessabi, AM1
Otsuka, T2
Tsuboi, Y3
-
15
-
-
0021393883
-
In vivo metal‐ion release from porous titanium‐fiber material
-
15 Ducheyne P, Willems G, Martens M, Helsen J. In vivo metal‐ion release from porous titanium‐fiber material. J Biomed Mater Res 1984 ; 18: 293–308.
-
(1984)
J Biomed Mater Res
, vol.18
, pp. 293-308
-
-
Ducheyne, P1
Willems, G2
Martens, M3
Helsen, J4
-
16
-
-
0026832945
-
The mechanisms of passive dissolution of titanium in a model physiological environment
-
16 Healy KE, Ducheyne P. The mechanisms of passive dissolution of titanium in a model physiological environment. J Biomed Mater Res 1992 ; 26: 319–338.
-
(1992)
J Biomed Mater Res
, vol.26
, pp. 319-338
-
-
Healy, KE1
Ducheyne, P2
-
17
-
-
0027765325
-
Metal release from titanium fixtures during placement in the mandible: an experimental study
-
17 Schliephake H, Reiss G, Urban R, Neukam FW, Guckel S. Metal release from titanium fixtures during placement in the mandible: an experimental study. Int J Oral Maxillofac Implants 1993 ; 8: 502–511.
-
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 502-511
-
-
Schliephake, H1
Reiss, G2
Urban, R3
Neukam, FW4
Guckel, S5
-
18
-
-
0028518655
-
Bone response to surface‐modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology
-
18 Larsson C, Thomsen P, Lausmaa J, Rodahl M, Kasemo B, Ericson LE. Bone response to surface‐modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. Biomaterials 1994 ; 15: 1062–1074.
-
(1994)
Biomaterials
, vol.15
, pp. 1062-1074
-
-
Larsson, C1
Thomsen, P2
Lausmaa, J3
Rodahl, M4
Kasemo, B5
Ericson, LE6
-
19
-
-
0030110849
-
Bone response to surface‐modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses
-
19 Larsson C, Thomsen P, Aronsson BO, et al. Bone response to surface‐modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses. Biomaterials 1996 ; 17: 605–616.
-
(1996)
Biomaterials
, vol.17
, pp. 605-616
-
-
Larsson, C1
Thomsen, P2
Aronsson, BO3
-
20
-
-
0027625479
-
Bone growth to metal implants is regulated by their surface chemical properties
-
20 Kazan R, Brener R, Oron U. Bone growth to metal implants is regulated by their surface chemical properties. Biomaterials 1993 ; 14: 570–574.
-
(1993)
Biomaterials
, vol.14
, pp. 570-574
-
-
Kazan, R1
Brener, R2
Oron, U3
-
21
-
-
0030269999
-
Bone bonding behavior of titanium and its alloys when coated with titanium oxide (TiO2) and titanium silicate (Ti5Si3)
-
21 Kitsugi T, Nakamura T, Oka M, et al. Bone bonding behavior of titanium and its alloys when coated with titanium oxide (TiO 2) and titanium silicate (Ti 5 Si 3). J Biomed Mater Res 1996 ; 32: 149–156.
-
(1996)
J Biomed Mater Res
, vol.32
, pp. 149-156
-
-
Kitsugi, T1
Nakamura, T2
Oka, M3
-
22
-
-
85120595383
-
Ion implantation, in: Metals handbook
-
22 Hochman RF. Ion implantation. In: Metals handbook. 9th Ed. Vol. 5 Surface cleaning, finishing, and coating. Metals Park, Ohio: American Society for Metals (ASM) International, 1987: 422–426.
-
(1987)
, pp. 422-426
-
-
Hochman, RF1
-
23
-
-
0032117334
-
Nitrogen ion implantation into three‐dimensional substrates by plasma source ion implantation
-
23 Baba K, Hatada R. Nitrogen ion implantation into three‐dimensional substrates by plasma source ion implantation. Mater Chem Physics 1998 ; 54: 135–138.
-
(1998)
Mater Chem Physics
, vol.54
, pp. 135-138
-
-
Baba, K1
Hatada, R2
-
24
-
-
0003882935
-
Parameters for characterising 3‐D surfaces, in: The development of methods for the characterization of roughness in three dimensions
-
24 Stout K‐J, Sullivan PJ, Dong WP, et al. Parameters for characterising 3‐D surfaces. In: The development of methods for the characterization of roughness in three dimensions. EUR 15178 EN of commission of the European Communities. Birmingham, England: University of Birmingham ; 1993: 216–250.
-
(1993)
, pp. 216-250
-
-
Stout, K‐J1
Sullivan, PJ2
Dong, WP3
-
25
-
-
0001047699
-
Die Trenn‐Dünnsghliff‐Technik zur Herstellung histologischer Präparate von nicht schneidbaren Geweben und Materialien
-
25 Donath K. Die Trenn‐Dünnsghliff‐Technik zur Herstellung histologischer Präparate von nicht schneidbaren Geweben und Materialien. Der Präparator 1988 ; 34: 197–206.
-
(1988)
Der Präparator
, vol.34
, pp. 197-206
-
-
Donath, K1
-
26
-
-
85120596322
-
Variation of surface nanomorphology during high energy ion implantation, in: Application of accelerators in research and industry
-
26 Io K, Kishimoto W, Ektessabi AM. Variation of surface nanomorphology during high energy ion implantation. In: Duggan JL, Morgan IL, eds. Application of accelerators in research and industry. New York: AIP Press, 1997: 965–968.
-
(1997)
, pp. 965-968
-
-
Io, K1
Kishimoto, W2
Ektessabi, AM3
-
27
-
-
0024655938
-
Inhibition of apatite formation by titanium and vanadium ions
-
27 Blumenthal NC, Cosma V. Inhibition of apatite formation by titanium and vanadium ions. J Biomed Mater Res 1989 ; 23: 13–22.
-
(1989)
J Biomed Mater Res
, vol.23
, pp. 13-22
-
-
Blumenthal, NC1
Cosma, V2
-
28
-
-
0031033347
-
Effects of metal ions on osteoblast‐like cell metabolism and differentiation
-
28 Sun ZL, Wataha JC, Hanks CT. Effects of metal ions on osteoblast‐like cell metabolism and differentiation. J Biomed Mater Res 1997 ; 34: 29–37.
-
(1997)
J Biomed Mater Res
, vol.34
, pp. 29-37
-
-
Sun, ZL1
Wataha, JC2
Hanks, CT3
-
29
-
-
0141547235
-
The interface between bone and metals with different surface properties. Light microscopic and ultrastructural studies
-
28 Larsson C. The interface between bone and metals with different surface properties. Light microscopic and ultrastructural studies. PhD thesis, Institute of Anatomy and Cell Biology, Göteborg University, Göteborg, Sweden, 1997.
-
(1997)
-
-
Larsson, C1
-
30
-
-
0030175433
-
Local accumulation of titanium released from a titanium implant in the absence of wear
-
30 Bianco PD, Ducheyne P, Cuckler JM. Local accumulation of titanium released from a titanium implant in the absence of wear. J Biomed Mater Res 1996 ; 31: 227–234.
-
(1996)
J Biomed Mater Res
, vol.31
, pp. 227-234
-
-
Bianco, PD1
Ducheyne, P2
Cuckler, JM3
|