Volumn 3, Issue 4, 2001, Pages 221-229

Application of oxygen ion implantation to titanium surfaces: Effects on surface characteristics, corrosion resistance, and bone response

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; ION; TITANIUM; TITANIUM DIOXIDE;

EID: 0035757352     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2001.tb00144.x     Document Type: Article
Times cited : (38)

References (30)
  • 1
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long‐lasting, direct bone‐to‐implant anchorage in man
    • 1 Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long‐lasting, direct bone‐to‐implant anchorage in man. Acta Orthop Scand 1981 ; 52: 155–170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T1    Branemark, PI2    Hansson, HA3    Lindstrom, J4
  • 2
    • 0002455249 scopus 로고
    • Bone tissue response, in: Tissue‐integrated prosthesis: osseointegration in clinical dentistry
    • 2 Albrektsson T. Bone tissue response. In: Branemark P‐I, Zarb GA, Albrektsson T, eds. Tissue‐integrated prosthesis: osseointegration in clinical dentistry. Chicago: Quintessence, 1985: 129–143.
    • (1985) , pp. 129-143
    • Albrektsson, T1
  • 3
    • 0002611019 scopus 로고
    • Osseointegration: a requiem for the periodontal ligament
    • 3 Zarb GA, Albrektsson T. Osseointegration: a requiem for the periodontal ligament Intn Periodontics Restorative Dent 1991 ; 11: 88–91.
    • (1991) Intn Periodontics Restorative Dent , vol.11 , pp. 88-91
    • Zarb, GA1    Albrektsson, T2
  • 4
    • 0013093214 scopus 로고
    • Corrosion of metallic implants and prosthetic devices, in: Metals handbook
    • 4 Fraker AC. Corrosion of metallic implants and prosthetic devices. In: Metals handbook. 9th Ed. Vol. 13. Metals Park, OH: American Society for Metals (ASM) International, 1987: 1324–1335.
    • (1987) , pp. 1324-1335
    • Fraker, AC1
  • 5
    • 0023384583 scopus 로고
    • The electrochemical behavior of metallic implant materials as an indicator of their biocom‐patibility
    • 5 Zitter H, Plenk H Jr. The electrochemical behavior of metallic implant materials as an indicator of their biocom‐patibility. J Biomed Mater Res 1987 ; 21: 881–896.
    • (1987) J Biomed Mater Res , vol.21 , pp. 881-896
    • Zitter, H1    Plenk, H2
  • 6
    • 0003993333 scopus 로고
    • The biomaterial‐tissue interface and its analogues in surface science and technology, in: The bone‐biomaterial interface
    • 6 Kasemo B, Lausmaa J. The biomaterial‐tissue interface and its analogues in surface science and technology. In: Davies JE, ed. The bone‐biomaterial interface. Toronto: University of Toronto Press, 1991: 19–32.
    • (1991) , pp. 19-32
    • Kasemo, B1    Lausmaa, J2
  • 7
    • 0000174683 scopus 로고
    • Corrosion of titanium and titanium alloys, in: Metals handbook
    • 7 Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. In: Metals handbook. 9th Ed. Vol. 13. Metals Park, OH: American Society for Metals (ASM) International, 1987: 669–706.
    • (1987) , pp. 669-706
    • Schutz, RW1    Thomas, DE2
  • 8
    • 0025414641 scopus 로고
    • Surface spectroscopic characterization of titanium implant materials
    • 8 Lausmaa J, Kasemo B, Mattsson H. Surface spectroscopic characterization of titanium implant materials. Appi Surface Sci 1990 ; 44: 133–146.
    • (1990) Appi Surface Sci , vol.44 , pp. 133-146
    • Lausmaa, J1    Kasemo, B2    Mattsson, H3
  • 9
    • 0032013713 scopus 로고    scopus 로고
    • Spectroscopic studies of three osseointegrated implants
    • 9 Sawase T, Hai K, Yoshida K, Bab K, Hatada R, Atsuta M. Spectroscopic studies of three osseointegrated implants. J Dent 1998 ; 26: 119–124.
    • (1998) J Dent , vol.26 , pp. 119-124
    • Sawase, T1    Hai, K2    Yoshida, K3    Bab, K4    Hatada, R5    Atsuta, M6
  • 10
    • 0021120213 scopus 로고
    • Metal ion release from titanium‐based prosthetic segmentai replacements of long bones in baboons: a long‐term study
    • 10 Woodman JL, Jacobs JJ, Galante JO, Urban RM. Metal ion release from titanium‐based prosthetic segmentai replacements of long bones in baboons: a long‐term study. J Orthop Res 1984 ; 1: 421–430.
    • (1984) J Orthop Res , vol.1 , pp. 421-430
    • Woodman, JL1    Jacobs, JJ2    Galante, JO3    Urban, RM4
  • 11
    • 0001882691 scopus 로고
    • The release of titanium into human bone from a titanium implant coated with plasma‐sprayed titanium, in: Clinical implant materials: advances in biomaterials. Vol. 9
    • 11 Osborn JF, Willich P, Meenen N. The release of titanium into human bone from a titanium implant coated with plasma‐sprayed titanium. In: Heimke G, Soltesz U, Lee AJC, eds. Clinical implant materials: advances in biomaterials. Vol. 9. Amsterdam: Elsevier, 1990: 75–80.
    • (1990) , pp. 75-80
    • Osborn, JF1    Willich, P2    Meenen, N3
  • 12
    • 0025642771 scopus 로고
    • Secondary ion mass spectrometry in the study of biomineralizations and biomaterials
    • 12 Lodding AR, Fischer PM, Odelius HA, et al. Secondary ion mass spectrometry in the study of biomineralizations and biomaterials. Analytica Chimica Acta 1990 ; 241: 299–314.
    • (1990) Analytica Chimica Acta , vol.241 , pp. 299-314
    • Lodding, AR1    Fischer, PM2    Odelius, HA3
  • 13
    • 0018449066 scopus 로고
    • In vitro corrosion testing of titanium surgical implant alloys: an approach to understanding titanium release from implants
    • 13 Solar RJ, Pollack SR, Korostoff E. In vitro corrosion testing of titanium surgical implant alloys: an approach to understanding titanium release from implants. J Biomed Mater Res 1979 ; 13: 217–250.
    • (1979) J Biomed Mater Res , vol.13 , pp. 217-250
    • Solar, RJ1    Pollack, SR2    Korostoff, E3
  • 14
    • 0002560938 scopus 로고
    • Application of micro beam PIXE to detection of titanium ion release from dental and orthopaedic implants
    • 14 Ektessabi AM, Otsuka T, Tsuboi Y, et al. Application of micro beam PIXE to detection of titanium ion release from dental and orthopaedic implants. Int J PIXE 1994 ; 4: 81–91.
    • (1994) Int J PIXE , vol.4 , pp. 81-91
    • Ektessabi, AM1    Otsuka, T2    Tsuboi, Y3
  • 15
    • 0021393883 scopus 로고
    • In vivo metal‐ion release from porous titanium‐fiber material
    • 15 Ducheyne P, Willems G, Martens M, Helsen J. In vivo metal‐ion release from porous titanium‐fiber material. J Biomed Mater Res 1984 ; 18: 293–308.
    • (1984) J Biomed Mater Res , vol.18 , pp. 293-308
    • Ducheyne, P1    Willems, G2    Martens, M3    Helsen, J4
  • 16
    • 0026832945 scopus 로고
    • The mechanisms of passive dissolution of titanium in a model physiological environment
    • 16 Healy KE, Ducheyne P. The mechanisms of passive dissolution of titanium in a model physiological environment. J Biomed Mater Res 1992 ; 26: 319–338.
    • (1992) J Biomed Mater Res , vol.26 , pp. 319-338
    • Healy, KE1    Ducheyne, P2
  • 17
    • 0027765325 scopus 로고
    • Metal release from titanium fixtures during placement in the mandible: an experimental study
    • 17 Schliephake H, Reiss G, Urban R, Neukam FW, Guckel S. Metal release from titanium fixtures during placement in the mandible: an experimental study. Int J Oral Maxillofac Implants 1993 ; 8: 502–511.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 502-511
    • Schliephake, H1    Reiss, G2    Urban, R3    Neukam, FW4    Guckel, S5
  • 18
    • 0028518655 scopus 로고
    • Bone response to surface‐modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology
    • 18 Larsson C, Thomsen P, Lausmaa J, Rodahl M, Kasemo B, Ericson LE. Bone response to surface‐modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. Biomaterials 1994 ; 15: 1062–1074.
    • (1994) Biomaterials , vol.15 , pp. 1062-1074
    • Larsson, C1    Thomsen, P2    Lausmaa, J3    Rodahl, M4    Kasemo, B5    Ericson, LE6
  • 19
    • 0030110849 scopus 로고    scopus 로고
    • Bone response to surface‐modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses
    • 19 Larsson C, Thomsen P, Aronsson BO, et al. Bone response to surface‐modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses. Biomaterials 1996 ; 17: 605–616.
    • (1996) Biomaterials , vol.17 , pp. 605-616
    • Larsson, C1    Thomsen, P2    Aronsson, BO3
  • 20
    • 0027625479 scopus 로고
    • Bone growth to metal implants is regulated by their surface chemical properties
    • 20 Kazan R, Brener R, Oron U. Bone growth to metal implants is regulated by their surface chemical properties. Biomaterials 1993 ; 14: 570–574.
    • (1993) Biomaterials , vol.14 , pp. 570-574
    • Kazan, R1    Brener, R2    Oron, U3
  • 21
    • 0030269999 scopus 로고    scopus 로고
    • Bone bonding behavior of titanium and its alloys when coated with titanium oxide (TiO2) and titanium silicate (Ti5Si3)
    • 21 Kitsugi T, Nakamura T, Oka M, et al. Bone bonding behavior of titanium and its alloys when coated with titanium oxide (TiO 2) and titanium silicate (Ti 5 Si 3). J Biomed Mater Res 1996 ; 32: 149–156.
    • (1996) J Biomed Mater Res , vol.32 , pp. 149-156
    • Kitsugi, T1    Nakamura, T2    Oka, M3
  • 22
    • 85120595383 scopus 로고
    • Ion implantation, in: Metals handbook
    • 22 Hochman RF. Ion implantation. In: Metals handbook. 9th Ed. Vol. 5 Surface cleaning, finishing, and coating. Metals Park, Ohio: American Society for Metals (ASM) International, 1987: 422–426.
    • (1987) , pp. 422-426
    • Hochman, RF1
  • 23
    • 0032117334 scopus 로고    scopus 로고
    • Nitrogen ion implantation into three‐dimensional substrates by plasma source ion implantation
    • 23 Baba K, Hatada R. Nitrogen ion implantation into three‐dimensional substrates by plasma source ion implantation. Mater Chem Physics 1998 ; 54: 135–138.
    • (1998) Mater Chem Physics , vol.54 , pp. 135-138
    • Baba, K1    Hatada, R2
  • 24
    • 0003882935 scopus 로고
    • Parameters for characterising 3‐D surfaces, in: The development of methods for the characterization of roughness in three dimensions
    • 24 Stout K‐J, Sullivan PJ, Dong WP, et al. Parameters for characterising 3‐D surfaces. In: The development of methods for the characterization of roughness in three dimensions. EUR 15178 EN of commission of the European Communities. Birmingham, England: University of Birmingham ; 1993: 216–250.
    • (1993) , pp. 216-250
    • Stout, K‐J1    Sullivan, PJ2    Dong, WP3
  • 25
    • 0001047699 scopus 로고
    • Die Trenn‐Dünnsghliff‐Technik zur Herstellung histologischer Präparate von nicht schneidbaren Geweben und Materialien
    • 25 Donath K. Die Trenn‐Dünnsghliff‐Technik zur Herstellung histologischer Präparate von nicht schneidbaren Geweben und Materialien. Der Präparator 1988 ; 34: 197–206.
    • (1988) Der Präparator , vol.34 , pp. 197-206
    • Donath, K1
  • 26
    • 85120596322 scopus 로고    scopus 로고
    • Variation of surface nanomorphology during high energy ion implantation, in: Application of accelerators in research and industry
    • 26 Io K, Kishimoto W, Ektessabi AM. Variation of surface nanomorphology during high energy ion implantation. In: Duggan JL, Morgan IL, eds. Application of accelerators in research and industry. New York: AIP Press, 1997: 965–968.
    • (1997) , pp. 965-968
    • Io, K1    Kishimoto, W2    Ektessabi, AM3
  • 27
    • 0024655938 scopus 로고
    • Inhibition of apatite formation by titanium and vanadium ions
    • 27 Blumenthal NC, Cosma V. Inhibition of apatite formation by titanium and vanadium ions. J Biomed Mater Res 1989 ; 23: 13–22.
    • (1989) J Biomed Mater Res , vol.23 , pp. 13-22
    • Blumenthal, NC1    Cosma, V2
  • 28
    • 0031033347 scopus 로고    scopus 로고
    • Effects of metal ions on osteoblast‐like cell metabolism and differentiation
    • 28 Sun ZL, Wataha JC, Hanks CT. Effects of metal ions on osteoblast‐like cell metabolism and differentiation. J Biomed Mater Res 1997 ; 34: 29–37.
    • (1997) J Biomed Mater Res , vol.34 , pp. 29-37
    • Sun, ZL1    Wataha, JC2    Hanks, CT3
  • 29
    • 0141547235 scopus 로고    scopus 로고
    • The interface between bone and metals with different surface properties. Light microscopic and ultrastructural studies
    • 28 Larsson C. The interface between bone and metals with different surface properties. Light microscopic and ultrastructural studies. PhD thesis, Institute of Anatomy and Cell Biology, Göteborg University, Göteborg, Sweden, 1997.
    • (1997)
    • Larsson, C1
  • 30
    • 0030175433 scopus 로고    scopus 로고
    • Local accumulation of titanium released from a titanium implant in the absence of wear
    • 30 Bianco PD, Ducheyne P, Cuckler JM. Local accumulation of titanium released from a titanium implant in the absence of wear. J Biomed Mater Res 1996 ; 31: 227–234.
    • (1996) J Biomed Mater Res , vol.31 , pp. 227-234
    • Bianco, PD1    Ducheyne, P2    Cuckler, JM3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.