메뉴 건너뛰기




Volumn 3, Issue 3, 2001, Pages 148-155

Perceptual changes in the anterior maxilla after placement of endosseous implants

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; BONE REGENERATION; CASE CONTROL STUDY; COMPARATIVE STUDY; DENTURE; FEMALE; HUMAN; JAW; MALE; MAXILLA; MECHANICAL STRESS; MIDDLE AGED; MOUTH MUCOSA; PHYSIOLOGY; REGRESSION ANALYSIS; SIGNAL PROCESSING; STATISTICS; TOOTH; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOUCH; VIBRATION;

EID: 0035748991     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2001.tb00135.x     Document Type: Article
Times cited : (20)

References (33)
  • 1
    • 0024496004 scopus 로고
    • Comparison of trigeminal receptor location and structure in the periodontal ligament of different types of teeth from the rat, cat, and monkey
    • 1 Byers MR, Dong WK. Comparison of trigeminal receptor location and structure in the periodontal ligament of different types of teeth from the rat, cat, and monkey. J Comp Neurol 1989 ; 279: 117–127.
    • (1989) J Comp Neurol , vol.279 , pp. 117-127
    • Byers, MR1    Dong, WK2
  • 2
    • 0027751110 scopus 로고
    • Comparison between teeth and implant‐supported prostheses regarding the passive threshold
    • 2 Jacobs R, van Steenberghe D. Comparison between teeth and implant‐supported prostheses regarding the passive threshold. Int J Oral Maxillofac Implants 1993 ; 8: 549–554.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 549-554
    • Jacobs, R1    van Steenberghe, D2
  • 3
    • 0007209986 scopus 로고    scopus 로고
    • Neurological versus psychophysical assessment of osseoperception, in: Osseoperception
    • 3 Jacobs R. Neurological versus psychophysical assessment of osseoperception. In: Jacobs R, ed. Osseoperception. Leuven: Department of Periodontology, Catholic University of Leuven, 1998: 75–88.
    • (1998) , pp. 75-88
    • Jacobs, R1
  • 4
    • 0001880006 scopus 로고    scopus 로고
    • Osseointegration: biotechnological perspective and clinical modality, in: Osseointegration in skeletal reconstruction and joint replacement
    • 4 Brånemark P‐I. Osseointegration: biotechnological perspective and clinical modality. In: Brånemark P‐I, Rydevik BL, Skalak R, eds. Osseointegration in skeletal reconstruction and joint replacement. Chicago: Quintessence, 1997: 1–24.
    • (1997) , pp. 1-24
    • Brånemark, P‐I1
  • 5
    • 0024794961 scopus 로고
    • The effect of tooth extraction on periodontal ligament mechanoreceptors represented in the mesencephalic nucleus of the cat
    • 5 Linden RW, Scott BJ. The effect of tooth extraction on periodontal ligament mechanoreceptors represented in the mesencephalic nucleus of the cat. Arch Oral Biol 1989 ; 34: 937–941.
    • (1989) Arch Oral Biol , vol.34 , pp. 937-941
    • Linden, RW1    Scott, BJ2
  • 6
    • 0003161355 scopus 로고    scopus 로고
    • Nerve regeneration after implantation in peri‐implant area. A histological study on different implant materials in dogs, in: Osseoperception
    • 6 Wang Y‐H, Kojo T, Ando H, et al. Nerve regeneration after implantation in peri‐implant area. A histological study on different implant materials in dogs. In: Jacobs R, ed. Osseoperception. Leuven: Department of Periodontology, Catholic University of Leuven, 1998: 3–11.
    • (1998) , pp. 3-11
    • Wang, Y‐H1    Kojo, T2    Ando, H3
  • 7
    • 0026135287 scopus 로고
    • Comparative evaluation of the oral tactile function by means of teeth or implant‐supported prostheses
    • 7 Jacobs R, van Steenberghe D. Comparative evaluation of the oral tactile function by means of teeth or implant‐supported prostheses. Clin Oral Implants Res 1991 ; 2: 75–80.
    • (1991) Clin Oral Implants Res , vol.2 , pp. 75-80
    • Jacobs, R1    van Steenberghe, D2
  • 8
    • 0029269182 scopus 로고
    • Quantitative evaluation of the masseteric postStimulus EMG complex following mechanical or acoustic stimulation of osseointegrated oral implants
    • 8 Jacobs R, van Steenberghe D. Quantitative evaluation of the masseteric postStimulus EMG complex following mechanical or acoustic stimulation of osseointegrated oral implants. Int J Oral Maxillofac Implants 1995 ; 10: 175–182.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 175-182
    • Jacobs, R1    van Steenberghe, D2
  • 9
    • 0026948275 scopus 로고
    • Influence of temperature and foil hardness on interocclusal tactile threshold
    • 9 Jacobs R, Schotte A, van Steenberghe D. Influence of temperature and foil hardness on interocclusal tactile threshold. J Periodont Res 1992 ; 27: 581–587.
    • (1992) J Periodont Res , vol.27 , pp. 581-587
    • Jacobs, R1    Schotte, A2    van Steenberghe, D3
  • 10
    • 0031151720 scopus 로고    scopus 로고
    • The stereognos‐tic ability of natural dentitions versus implant‐supported fixed prostheses or overdentures
    • 10 Jacobs R, Bou Serhal C, van Steenberghe D. The stereognos‐tic ability of natural dentitions versus implant‐supported fixed prostheses or overdentures. Clin Oral Invest 1997 ; 1: 89–94.
    • (1997) Clin Oral Invest , vol.1 , pp. 89-94
    • Jacobs, R1    Bou Serhal, C2    van Steenberghe, D3
  • 12
    • 0007784429 scopus 로고    scopus 로고
    • Physiological detection thresholds for vibrotactile and pressure stimulation of prosthetic limbs using bone‐anchored or soft tissue support, in: Osseoperception
    • 12 Jacobs R, Brånemark R, Olmarker K, Rydevik B, van Steenberghe D, Brånemark P‐I. Physiological detection thresholds for vibrotactile and pressure stimulation of prosthetic limbs using bone‐anchored or soft tissue support. In: Jacobs R, ed. Osseoperception. Leuven: Department of Periodontology, Catholic University of Leuven, 1998: 125–142.
    • (1998) , pp. 125-142
    • Jacobs, R1    Brånemark, R2    Olmarker, K3    Rydevik, B4    van Steenberghe, D5    Brånemark, P‐I6
  • 13
    • 0030090618 scopus 로고    scopus 로고
    • Thresholds for tactile sensitivity perceived with dental implants remain unchanged during a healing phase of 3 months
    • 13 Keller D, Hämmerle CH, Lang NP. Thresholds for tactile sensitivity perceived with dental implants remain unchanged during a healing phase of 3 months. Clin Oral Implants Res 1996 ; 7: 48–54.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 48-54
    • Keller, D1    Hämmerle, CH2    Lang, NP3
  • 14
    • 84989509317 scopus 로고
    • Oral function in patients wearing fixed prosthesis on osseointegrated implants in the maxilla: 3‐year follow‐up study
    • 14 Lundqvist S, Haraldson T. Oral function in patients wearing fixed prosthesis on osseointegrated implants in the maxilla: 3‐year follow‐up study. Scand J Dent Res 1992 ; 100: 279–283.
    • (1992) Scand J Dent Res , vol.100 , pp. 279-283
    • Lundqvist, S1    Haraldson, T2
  • 15
    • 0029303075 scopus 로고
    • Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants
    • 15 Mericske‐Stera R, Assal P, Mericske E, Bürgin W. Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants 1995 ; 10: 345–354.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 345-354
    • Mericske‐Stera, R1    Assal, P2    Mericske, E3    Bürgin, W4
  • 17
    • 0004926361 scopus 로고    scopus 로고
    • A technique for determination of vibrotactile force threshold levels in patients with orthopaedic osseointegrated implants, in: Osseoperception
    • 17 Stenfelt S, Jacobs R, Olmarker K, Rydevik B, Brånemark P‐I. A technique for determination of vibrotactile force threshold levels in patients with orthopaedic osseointegrated implants. In: Jacobs R, ed. Osseoperception. Leuven: Department of Periodontology, Catholic University of Leuven, 1998: 105–123.
    • (1998) , pp. 105-123
    • Stenfelt, S1    Jacobs, R2    Olmarker, K3    Rydevik, B4    Brånemark, P‐I5
  • 18
    • 0027503333 scopus 로고
    • Changes in sensation after nerve injury or amputation: the role of central factors
    • 18 Braune S, Schady W. Changes in sensation after nerve injury or amputation: the role of central factors. J Neurol Neurosurg Psychiatry 1993 ; 56: 393–399.
    • (1993) J Neurol Neurosurg Psychiatry , vol.56 , pp. 393-399
    • Braune, S1    Schady, W2
  • 19
    • 0023000998 scopus 로고
    • Digital vibrogram: a new diagnostic tool for sensory testing in compression neuropathy
    • 19 Lundborg G, Lie‐Stenström AK, Sollerman C, Strömberg T, Pyykkö I. Digital vibrogram: a new diagnostic tool for sensory testing in compression neuropathy. J Hand Surg [Am] 1986 ; 11: 693–699.
    • (1986) J Hand Surg [Am] , vol.11 , pp. 693-699
    • Lundborg, G1    Lie‐Stenström, AK2    Sollerman, C3    Strömberg, T4    Pyykkö, I5
  • 21
    • 0027054337 scopus 로고
    • Vibrotactile function of the hand in compression and vibration‐induced neuropathy. Sensibility index: a new measure
    • 21 Lundborg G, Dahlin LB, Lundström R, Necking LE, Strömberg T. Vibrotactile function of the hand in compression and vibration‐induced neuropathy. Sensibility index: a new measure. Scand J Plast Reconstr Surg Hand Surg 1992 ; 26: 275–279.
    • (1992) Scand J Plast Reconstr Surg Hand Surg , vol.26 , pp. 275-279
    • Lundborg, G1    Dahlin, LB2    Lundström, R3    Necking, LE4    Strömberg, T5
  • 22
    • 0026666410 scopus 로고
    • Vibrotactile perception threshold measurements for diagnosis of sensory neuropathy. Description of a reference population
    • 22 Lundström R, Strömberg T, Lundborg G. Vibrotactile perception threshold measurements for diagnosis of sensory neuropathy. Description of a reference population. Int Arch Occup Environ Health 1992 ; 64: 201–207.
    • (1992) Int Arch Occup Environ Health , vol.64 , pp. 201-207
    • Lundström, R1    Strömberg, T2    Lundborg, G3
  • 24
    • 0018333423 scopus 로고
    • Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin
    • 24 Johansson RJ, Vallbo AB. Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin. J Physiol (Lond) 1979 ; 286: 283–300.
    • (1979) J Physiol (Lond) , vol.286 , pp. 283-300
    • Johansson, RJ1    Vallbo, AB2
  • 25
    • 0018651918 scopus 로고
    • Detection of tactile stimuli. Threshold of afferent units related to psychophysical threshold in human hand
    • 25 Johansson RJ, Vallbo ÅB. Detection of tactile stimuli. Threshold of afferent units related to psychophysical threshold in human hand. J Physiol (Lond) 1979 ; 297: 405–422.
    • (1979) J Physiol (Lond) , vol.297 , pp. 405-422
    • Johansson, RJ1    Vallbo, ÅB2
  • 26
    • 0018868368 scopus 로고
    • Spatial properties of the population of mechanoreceptive units in the glabrous skin of human hand
    • 26 Johansson RJ, Vallbo ÅB. Spatial properties of the population of mechanoreceptive units in the glabrous skin of human hand. Brain Res 1980 ; 184: 353–366.
    • (1980) Brain Res , vol.184 , pp. 353-366
    • Johansson, RJ1    Vallbo, ÅB2
  • 27
    • 0018865895 scopus 로고
    • Thresholds of mechanoreceptive afferents in the human hand as measured with von Frey hairs
    • 27 Johansson RJ, Vallbo ÅB, Westlig G. Thresholds of mechanoreceptive afferents in the human hand as measured with von Frey hairs. Brain Res 1980 ; 184: 343–351.
    • (1980) Brain Res , vol.184 , pp. 343-351
    • Johansson, RJ1    Vallbo, ÅB2    Westlig, G3
  • 28
    • 0011148558 scopus 로고
    • Physiology of mechanical senses of the oral structure, in: Frontiers of oral physiology. Oral sensory mechanism
    • 28 Sakada S. Physiology of mechanical senses of the oral structure. In: Kawamura Y, ed. Frontiers of oral physiology. Oral sensory mechanism. Basel: Karger, 1983: 1–32.
    • (1983) , pp. 1-32
    • Sakada, S1
  • 29
    • 0018743669 scopus 로고
    • The structure and function of peri‐odontal innervation. A review of the literature
    • 29 van Steenberghe D. The structure and function of peri‐odontal innervation. A review of the literature. J Periodont Res 1979 ; 14: 185–203.
    • (1979) J Periodont Res , vol.14 , pp. 185-203
    • van Steenberghe, D1
  • 30
    • 0014097020 scopus 로고
    • Characteristics of innervation and nerve ending in cat's mandibular periosteum
    • 30 Sakada S, Maeda K. Characteristics of innervation and nerve ending in cat's mandibular periosteum. Bull Tokyo Dent Coll 1967 ; 8: 77–94.
    • (1967) Bull Tokyo Dent Coll , vol.8 , pp. 77-94
    • Sakada, S1    Maeda, K2
  • 31
    • 84985196246 scopus 로고
    • Correlation between histological structure and response to pressure of mechanoreceptors in the cat mandibular periosteum
    • 31 Sakada S, Maeda K. Correlation between histological structure and response to pressure of mechanoreceptors in the cat mandibular periosteum. Bull Tokyo Dent Coll 1967 ; 8: 181–196.
    • (1967) Bull Tokyo Dent Coll , vol.8 , pp. 181-196
    • Sakada, S1    Maeda, K2
  • 32
    • 0030277224 scopus 로고    scopus 로고
    • Electrophysiologic evidence showing the existence of sensory receptors within the alveolar bone in anesthetized cats
    • 32 Héiaud J, Orofino I, Trub M, Mei N. Electrophysiologic evidence showing the existence of sensory receptors within the alveolar bone in anesthetized cats. Int J Oral Maxillofac Implants 1996 ; 11: 800–805.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 800-805
    • Héiaud, J1    Orofino, I2    Trub, M3    Mei, N4
  • 33
    • 84995743125 scopus 로고
    • The use of masking limitations in clinical audiom‐etry
    • 33 König E. The use of masking limitations in clinical audiom‐etry. Acta Otolaryngol Suppl (Stockh) 1962 ; 180: 1–51.
    • (1962) Acta Otolaryngol Suppl (Stockh) , vol.180 , pp. 1-51
    • König, E1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.