Volumn , Issue , 2001, Pages 709-712
|
Aging diagnosis of large generator stator winding insulation based on ac dielectric characteristic parameters
a a a a a |
Author keywords
AC dielectric characteristic parameter; Insulation diagnosis; Partial discharge; Stator winding insulation
|
Indexed keywords
AGING OF MATERIALS;
CAPACITANCE;
DIELECTRIC LOSSES;
ELECTRIC BREAKDOWN;
ELECTRIC CURRENTS;
ELECTRIC GENERATORS;
ELECTRIC MACHINERY TESTING;
NUMERICAL METHODS;
PARTIAL DISCHARGES;
STATORS;
STRESSES;
AC CURRENT RAPID INCREASE INDEX;
AC CURRENT RAPID RATE;
AC DIELECTRIC CHARACTERISTIC PARAMETERS;
AGING DIAGNOSIS;
AGING TEST;
FIRST RAPID INCREASE POINT;
PARTIAL DISCHARGE INTENSITY INDEX;
PARTIAL DISCHARGE PHASE INDEX;
SECOND RAPID INCREASE POINT;
STATOR WINDING INSULATION;
ELECTRIC MACHINE INSULATION;
|
EID: 0035719262
PISSN: None
EISSN: None
Source Type: Conference Proceeding
DOI: None Document Type: Conference Paper |
Times cited : (7)
|
References (8)
|