메뉴 건너뛰기




Volumn 18, Issue 12, 2001, Pages 3018-3036

Optical tomographic imaging of dynamic features of dense-scattering media

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD VESSEL; BREAST TUMOR; COMPUTER SIMULATION; FEMALE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; MAMMOGRAPHY; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICS; PATHOLOGY; RADIATION SCATTERING; THEORETICAL MODEL; TOMOGRAPHY; VASCULARIZATION;

EID: 0035651194     PISSN: 10847529     EISSN: 15208532     Source Type: Journal    
DOI: 10.1364/JOSAA.18.003018     Document Type: Article
Times cited : (128)

References (77)
  • 2
    • 0029620918 scopus 로고
    • Determination of optical properties and blood oxygenation in tissue using continuous NIR light
    • H. Liu, D. A. Boas, Y. Zhang, A. G. Yodh, and B. Chance, “Determination of optical properties and blood oxygenation in tissue using continuous NIR light,” Phys. Med. Biol. 40, 1983-1993 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1983-1993
    • Liu, H.1    Boas, D.A.2    Zhang, Y.3    Yodh, A.G.4    Chance, B.5
  • 3
    • 0029148149 scopus 로고
    • Influence of blood vessels on the measurement of hemoglobin oxygenation as determined by time-resolved re- flectance spectroscopy
    • H. Liu, B. Chance, A. H. Hielscher, S. L. Jacques, and F. K. Tittel, “Influence of blood vessels on the measurement of hemoglobin oxygenation as determined by time-resolved re- flectance spectroscopy,”Med. Phys. 22, 1209-1217 (1995).
    • (1995) Med. Phys , vol.22 , pp. 1209-1217
    • Liu, H.1    Chance, B.2    Hielscher, A.H.3    Jacques, S.L.4    Tittel, F.K.5
  • 4
    • 85010136806 scopus 로고
    • Cardiovascular control and integrated re- sponses
    • (Best and Taylor’s) Physiological Basis of Medical Practice, 11th ed., J. B. West, ed. Williams and Wilkins, Baltimore, Md., Chap
    • J. W. Covell, “Cardiovascular control and integrated re- sponses,” in (Best and Taylor’s) Physiological Basis of Medical Practice, 11th ed., J. B. West, ed. (Williams and Wilkins, Baltimore, Md., 1985), Chap. 16.
    • (1985) , pp. 16
    • Covell, J.W.1
  • 5
    • 0344082384 scopus 로고    scopus 로고
    • Os- cihations in cerebral haemodynamics
    • Oxygen Transport to Tissue XXI, Vol. 471 of Advances in Experimental Medicine and Biology, A. Eke and D. T. Delpy, eds., Kluwer Academic/Plenum, New York
    • C. E. Elwell, R. Springett, E. Hillman, and D. T. Delpy, “Os- cihations in cerebral haemodynamics,” in Oxygen Transport to Tissue XXI, Vol. 471 of Advances in Experimental Medicine and Biology, A. Eke and D. T. Delpy, eds. (Kluwer Academic/Plenum, New York, 1999), pp. 57-65.
    • (1999) , pp. 57-65
    • Elwell, C.E.1    Springett, R.2    Hillman, E.3    Delpy, D.T.4
  • 7
    • 0003136077 scopus 로고    scopus 로고
    • On-line optical imaging of the human brain with 160-ms temporal resolution
    • http://www.opticsexpress.org
    • M. A. Franceschini, V. Toronov, M. E. Filiaci, E. Gratton, and S. Fantini, “On-line optical imaging of the human brain with 160-ms temporal resolution,” Opt. Express 6, 49-57 (2000). http://www.opticsexpress.org.
    • (2000) Opt. Express , vol.6 , pp. 49-57
    • Franceschini, M.A.1    Toronov, V.2    Filiaci, M.E.3    Gratton, E.4    Fantini, S.5
  • 8
    • 0034287394 scopus 로고    scopus 로고
    • Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
    • A. Zourabian, A. Siegel, B. Chance, N. Ramanujan, M. Rode, and D. A. Boas, “Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry,” J. Biomed. Opt. 5, 391 -405 (2000).
    • (2000) J. Biomed. Opt. , vol.5
    • Zourabian, A.1    Siegel, A.2    Chance, B.3    Ramanujan, N.4    Rode, M.5    Boas, D.A.6
  • 9
    • 0030843420 scopus 로고    scopus 로고
    • Non-invasive optical spectros- copy and imaging of human brain function
    • A. Villringer and B. Chance, “Non-invasive optical spectros- copy and imaging of human brain function,” Trends Neurosa. 20, 435-442 (1997).
    • (1997) Trends Neurosa , vol.20 , pp. 435-442
    • Villringer, A.1    Chance, B.2
  • 10
    • 84894001474 scopus 로고    scopus 로고
    • Initial clinical testing of the UCL 32 channel time-resolved instru- ment for optical tomography
    • Biomedical Topical Meetings, OSA Technical DigestOptical Society of America, Washington D.C
    • E. M. C. Hillman, J. C. Hebden, F. E. W. Schmidt, S. R. Ar- ridge, M. E. Fry, M. Schweiger, and D. T. Delpy, “Initial clinical testing of the UCL 32 channel time-resolved instru- ment for optical tomography,” in Biomedical Topical Meetings, OSA Technical Digest (Optical Society of America, Washington D.C., 2000), pp. 100-102.
    • (2000) , pp. 100-102
    • Hillman, E.M.C.1    Hebden, J.C.2    Schmidt, F.E.W.3    Ar-Ridge, S.R.4    Fry, M.E.5    Schweiger, M.6    Delpy, D.T.7
  • 11
    • 0032606653 scopus 로고    scopus 로고
    • Spectroscopic diffuse op tical tomography for the quantitative assessment of hemo- globin concentration and oxygen saturation in breast tis- sue
    • T. O. McBride, B. W. Pogue, E. D. Gerety, S. B. Poplack, U. L. Osterberg, and K. D. Paulsen, “Spectroscopic diffuse op tical tomography for the quantitative assessment of hemo- globin concentration and oxygen saturation in breast tis- sue,” Appl. Opt. 38, 5480-5490 (1999).
    • (1999) Appl. Opt , vol.38 , pp. 5480-5490
    • McBride, T.O.1    Pogue, B.W.2    Gerety, E.D.3    Poplack, S.B.4    Osterberg, U.L.5    Paulsen, K.D.6
  • 13
    • 0033737411 scopus 로고    scopus 로고
    • Spa- tiotemporal imaging of vascular reactivity
    • Physiology and Function from Multidimensional Imaging, A. V. Clough and C.-T. Chen, eds., Proc. SPIE 3978
    • H. L. Graber, C. H. Schmitz, Y. Pei, S. Zhong, S.-L. S. Bar- bour, S. Blattman, T. Panetta, and R. L. Barbour, “Spa- tiotemporal imaging of vascular reactivity,” in Physiology and Function from Multidimensional Imaging, A. V. Clough and C.-T. Chen, eds., Proc. SPIE 3978, 32-43 (2000).
    • (2000) , pp. 32-43
    • Graber, H.L.1    Schmitz, C.H.2    Pei, Y.3    Zhong, S.4    Bar-Bour, S.-L.S.5    Blattman, S.6    Panetta, T.7    Barbour, R.L.8
  • 14
    • 0005248395 scopus 로고    scopus 로고
    • Dynamic imaging of muscle activ- ity by optical tomography
    • Biomedical Topical Meetings, OSA Technical Digest Optical Society of America, Washington, D.C
    • H. L. Graber, S. Zheng, Y. Pei, C. H. Schmitz, I. Arif, J. Hira, and R. L. Barbour, “Dynamic imaging of muscle activ- ity by optical tomography,” in Biomedical Topical Meetings, OSA Technical Digest (Optical Society of America, Washington, D.C., 2000), pp. 407-408.
    • (2000) , pp. 407-408
    • Graber, H.L.1    Zheng, S.2    Pei, Y.3    Schmitz, C.H.4    Arif, I.5    Hira, J.6    Barbour, R.L.7
  • 15
    • 0005332997 scopus 로고    scopus 로고
    • Optical imaging of the response of vascular dynamics to a cold shock
    • Biomedical Topical Meetings, OSA Technical DigestOptical Society of America, Washington, D.C
    • R. L. Barbour, H. L. Graber, S. Zheng, Y. Pei, J. Hira, and I. Arif, “Optical imaging of the response of vascular dynamics to a cold shock,” in Biomedical Topical Meetings, OSA Technical Digest (Optical Society of America, Washington, D.C., 2000), pp. 430-432.
    • (2000) , pp. 430-432
    • Barbour, R.L.1    Graber, H.L.2    Zheng, S.3    Pei, Y.4    Hira, J.5    Arif, I.6
  • 16
    • 85010099662 scopus 로고    scopus 로고
    • Imaging of differential reactivity of the vascular tree in the human forearm by optical tomography
    • Biomedical Topical Meetings, OSA Technical (Optical Society of America, Washington D.C
    • S. Blattman, H. L. Graber, S. Zheng, Y. Pei, J. Hira, I. Arif, and R. L. Barbour, “Imaging of differential reactivity of the vascular tree in the human forearm by optical tomography,” in Biomedical Topical Meetings, OSA Technical (Optical Society of America, Washington D.C., 2000), pp. 458460.
    • (2000) , pp. 458460
    • Blattman, S.1    Graber, H.L.2    Zheng, S.3    Pei, Y.4    Hira, J.5    Arif, I.6    Barbour, R.L.7
  • 17
    • 0028298129 scopus 로고
    • Angiogenesis and breast cancer
    • J. Folkman, “Angiogenesis and breast cancer,” J. Clin. On- col. 12, 441-443 (1994).
    • (1994) J. Clin. On- Col. , vol.12 , pp. 441-443
    • Folkman, J.1
  • 19
    • 8644270646 scopus 로고    scopus 로고
    • Sevick-Muraca, “Optical properties of normal and diseased breast tissues: Prognosis for optical mammography,”J. Biomed
    • T. L. Troy, D. L. Page, and E. M. Sevick-Muraca, “Optical properties of normal and diseased breast tissues: prognosis for optical mammography,”J. Biomed. Opt. 1, 343-355 (1996).
    • (1996) Opt , vol.1 , pp. 343-355
    • Troy, T.L.1    Page, D.L.2
  • 20
    • 0031901460 scopus 로고    scopus 로고
    • Com- parison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heteroge- neous tissues
    • A. H. Hielscher, R. E. Alcouffe, and R. L. Barbour, “Com- parison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heteroge- neous tissues,” Phys. Med. Biol. 43, 1285-1302 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1285-1302
    • Hielscher, A.H.1    Alcouffe, R.E.2    Barbour, R.L.3
  • 23
    • 0024313515 scopus 로고
    • The optical properties of aqueous suspensions of Intralipid, a fat emulsion
    • I. Driver, J. W. Feather, P. R. King, and J. B. Dawson, “The optical properties of aqueous suspensions of Intralipid, a fat emulsion,” Phys. Med. Biol. 34, 1927-1930 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1927-1930
    • Driver, I.1    Feather, J.W.2    King, P.R.3    Dawson, J.B.4
  • 24
    • 0026630107 scopus 로고
    • Optical properties of Intraplipid: A phantom medium for light propagation studies
    • Lasers Surg. Med
    • S. T. Flock, S. L. Jacques, B. C. Wilson, W. M. Star, and M. J. C. van Gemert, “Optical properties of Intraplipid: a phantom medium for light propagation studies,” Lasers Surg. Med. 12, 510-519 (1992).
    • (1992) , vol.12 , pp. 510-519
    • Flock, S.T.1    Jacques, S.L.2    Wilson, B.C.3    Star, W.M.4    Van Gemert, M.J.C.5
  • 25
    • 0015604413 scopus 로고
    • Optical constants of water in the 200-nm to 200-^m wavelength region
    • G. M. Hale and M. R. Querry, “Optical constants of water in the 200-nm to 200-^m wavelength region,” Appl. Opt. 12, 555-563 (1973).
    • (1973) Appl. Opt. , vol.12 , pp. 555-563
    • Hale, G.M.1    Querry, M.R.2
  • 26
    • 0005367799 scopus 로고    scopus 로고
    • Development and evaluation of the IRIS- OPTIscanner, a general-purpose optical tomographic imaging system
    • Advances in Optical Imaging and Photon Migration J. G. Fujimoto and M. S. Patterson, eds., Vol. 21 of OSA Trends in Optics and Photonics Series (Optical Society of America, Washington, D.C
    • R. L. Barbour, R. Andronica, Q. Sha, H. L. Graber, and I. Soller, “Development and evaluation of the IRIS- OPTIscanner, a general-purpose optical tomographic imaging system,” in Advances in Optical Imaging and Photon Migration J. G. Fujimoto and M. S. Patterson, eds., Vol. 21 of OSA Trends in Optics and Photonics Series (Optical Society of America, Washington, D.C., 1998), pp. 251-255.
    • (1998) , pp. 251-255
    • Barbour, R.L.1    Andronica, R.2    Sha, Q.3    Graber, H.L.4    Soller, I.5
  • 27
    • 0001671376 scopus 로고    scopus 로고
    • Influence of sys- tematic errors in reference states on image quality and on stability of derived information for DC optical imaging
    • Y. Pei, H. L. Graber, and R. L. Barbour, “Influence of sys- tematic errors in reference states on image quality and on stability of derived information for DC optical imaging,” Appl. Opt. 40, 5755-5769 (2001).
    • (2001) Appl. Opt. , vol.40 , pp. 5755-5769
    • Pei, Y.1    Graber, H.L.2    Barbour, R.L.3
  • 28
    • 85010179699 scopus 로고    scopus 로고
    • Imaging of spa- tiotemporal coincident states by dynamic optical tomography
    • Ref
    • H. L. Graber, Y. Pei, and R. L. Barbour, “Imaging of spa- tiotemporal coincident states by dynamic optical tomography,” in Ref. 1, pp. 153-163.
    • , vol.1 , pp. 153-163
    • Graber, H.L.1    Pei, Y.2    Barbour, R.L.3
  • 29
  • 30
    • 85010179688 scopus 로고    scopus 로고
    • Using MATLAB Version 5, (The Mathworks, Inc., Natick, Mass., 1998) Chap. 5; http://www.mathworks.com/access/helpdesk/help/techdoc/ref/griddata.shtml
    • Using MATLAB Version 5, (The Mathworks, Inc., Natick, Mass., 1998) Chap. 5; http://www.mathworks.com/access/helpdesk/help/techdoc/ref/griddata.shtml.
  • 31
    • 85010179686 scopus 로고    scopus 로고
    • Ref. 31; http://www.mathworks.com/access/helpdesk/help/techdoc/ref/delaunay.shtml
    • Ref. 31; http://www.mathworks.com/access/helpdesk/help/techdoc/ref/delaunay.shtml.
  • 34
    • 85010152724 scopus 로고    scopus 로고
    • Signal Processing Toolbox User’s Guide (Version 4) (The
    • Signal Processing Toolbox User’s Guide (Version 4) (The
  • 35
    • 85010179695 scopus 로고    scopus 로고
    • www.mathworks.com/access/helpdesk/help/toolbox/signal/fft.shtml
    • www.mathworks.com/access/helpdesk/help/toolbox/signal/fft.shtml.
  • 36
    • 85010152716 scopus 로고    scopus 로고
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
  • 37
    • 85010169090 scopus 로고    scopus 로고
    • toolbox/signal/xcorr.shtml
    • toolbox/signal/xcorr.shtml.
  • 38
    • 85010166454 scopus 로고    scopus 로고
    • As the temporal variations of the target media used in the studies considered here were perfectly periodic, the length and number of records can be set to any desired value. The effects of record number and length (and also other considerations such as filtering and windowing) lie outside the scope of the present report
    • As the temporal variations of the target media used in the studies considered here were perfectly periodic, the length and number of records can be set to any desired value. The effects of record number and length (and also other considerations such as filtering and windowing) lie outside the scope of the present report.
  • 39
    • 85010136792 scopus 로고    scopus 로고
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
  • 40
    • 85010106542 scopus 로고    scopus 로고
    • toolbox/signal/csd.shtml
    • toolbox/signal/csd.shtml.
  • 41
    • 85010169100 scopus 로고    scopus 로고
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
    • Ref. 35; http://www.mathworks.com/access/helpdesk/help/
  • 42
    • 85010104746 scopus 로고    scopus 로고
    • toolbox/signal/csd.shtml
    • toolbox/signal/csd.shtml.
  • 43
    • 85010119256 scopus 로고    scopus 로고
    • The last interpretation given is particularly intriguing for us, as it immediately brings to mind an analogy between this general concept of signal coherence and the particular physical meaning of “coherence” that applies to light. It suggests that the “coherence radius” and “coherence time” that could be defined for each pixel in an image time series may be parameters worth considering
    • The last interpretation given is particularly intriguing for us, as it immediately brings to mind an analogy between this general concept of signal coherence and the particular physical meaning of “coherence” that applies to light. It suggests that the “coherence radius” and “coherence time” that could be defined for each pixel in an image time series may be parameters worth considering.
  • 44
    • 0000060666 scopus 로고
    • Application of the finite-element method for the forward and inverse mod- els in optical tomography
    • M. Schweiger, S. R. Arridge, and D. T. Delpy, “Application of the finite-element method for the forward and inverse mod- els in optical tomography,” J. Math. Imag. Vision 3, 263283 (1993).
    • (1993) J. Math. Imag. Vision , vol.3 , pp. 263283
    • Schweiger, M.1    Arridge, S.R.2    Delpy, D.T.3
  • 45
    • 85010134626 scopus 로고    scopus 로고
    • Frequency-domain optical image reconstruction in turbid media: An experimental study of single-targe
    • H. Jiang, K. D. Paulsen, U. L. Osterberg, and M. S. Patter- son, “Frequency-domain optical image reconstruction in turbid media: an experimental study of single-target
    • Jiang, H.1    Paulsen, K.D.2    Osterberg, U.L.3    Patter-Son, M.S.4
  • 46
    • 85010166457 scopus 로고    scopus 로고
    • Tectability
    • tectability,”Appl. Opt. 36, 52-63 (1997).
    • (1997) Appl. Opt , vol.36 , pp. 52-63
  • 47
    • 0000381783 scopus 로고    scopus 로고
    • Differential diffuse optical tomography
    • http://www.opticsexpress.org
    • V. Ntziachristos, B. Chance, and A. G. Yodh, “Differential diffuse optical tomography,” Opt. Express 5, 230-242 (1999), http://www.opticsexpress.org.
    • (1999) Opt. Express , vol.5 , pp. 230-242
    • Ntziachristos, V.1    Chance, B.2    Yodh, A.G.3
  • 48
    • 85010166449 scopus 로고    scopus 로고
    • Vascularization, blood flow, oxygenation, tissue pH, and bioenergetic status of human breast cancer
    • Oxygen Transport to Tissue XVIII (Advances in Experimental Medicine and Biology)
    • P. Vaupel, “Vascularization, blood flow, oxygenation, tissue pH, and bioenergetic status of human breast cancer,” in Oxygen Transport to Tissue XVIII (Advances in Experimental Medicine and Biology)
    • Vaupel, P.1
  • 49
    • 85010166447 scopus 로고    scopus 로고
    • Plenum, New York, Vol
    • E. M. Nemoto and J. C. La- Manna, eds. (Plenum, New York, 1997), Vol. 411, pp. 243254.
    • (1997) , vol.411 , pp. 243254
    • Nemoto, E.M.1    La-Manna, J.C.2
  • 50
    • 0022451999 scopus 로고
    • Drug- and temperature- induced changes in peripheral circulation measured by laser-Doppler flowmetry and digital-pulse plethysmogra- phy
    • S. Sunberg and M. Castren, “Drug- and temperature- induced changes in peripheral circulation measured by laser-Doppler flowmetry and digital-pulse plethysmogra- phy,” Scand. J. Clin. Lab. Invest. 46, 359-365 (1986).
    • (1986) Scand. J. Clin. Lab. Invest. , vol.46 , pp. 359-365
    • Sunberg, S.1    Castren, M.2
  • 51
    • 0029057596 scopus 로고
    • Blood flow in breast cancer and fi- broadenoma estimated by colour Doppler ultrasonography
    • C. Holvombe, N. Pugh, K. Lyons, A. Douglas-Jones, R. E. Mansel, and K. Horgan, “Blood flow in breast cancer and fi- broadenoma estimated by colour Doppler ultrasonography,” Br. J. Surg. 82, 787-788 (1995).
    • (1995) Br. J. Surg. , vol.82 , pp. 787-788
    • Holvombe, C.1    Pugh, N.2    Lyons, K.3    Douglas-Jones, A.4    Mansel, R.E.5    Horgan, K.6
  • 52
    • 0038340459 scopus 로고    scopus 로고
    • Respira- tory system
    • The Biomedical Engineering Handbook, 2nd ed., J. D. Bronzino, ed.CRC Press, Boca Raton, Fla., Chap
    • A. T. Johnson, C. G. Lausted, and J. D. Bronzino, “Respira- tory system,” in The Biomedical Engineering Handbook, 2nd ed., J. D. Bronzino, ed. (CRC Press, Boca Raton, Fla., 2000), Chap. 7.
    • (2000) , pp. 7
    • Johnson, A.T.1    Lausted, C.G.2    Bronzino, J.D.3
  • 53
    • 0025352132 scopus 로고
    • Frequency analysis of the peripheral pulse wave detected in the finger with a photoplethysmograph
    • M. H. Sherebrin and R. Z. Sherebrin, “Frequency analysis of the peripheral pulse wave detected in the finger with a photoplethysmograph,” IEEE Trans. Biomed. Eng. 37, 313 - 317 (1990).
    • (1990) IEEE Trans. Biomed. Eng , pp. 317
    • Sherebrin, M.H.1    Sherebrin, R.Z.2
  • 54
    • 0000662951 scopus 로고    scopus 로고
    • Noninvasive arterial blood pressure and mechanics
    • The Biomedical Engineering Handbook, 2nd ed., J. D. Bronzino, ed. (CRC Press, Boca Raton, Fla., Chap
    • G. Drzewiecki, “Noninvasive arterial blood pressure and mechanics,” in The Biomedical Engineering Handbook, 2nd ed., J. D. Bronzino, ed. (CRC Press, Boca Raton, Fla., 2000), Chap. 71.
    • (2000) , pp. 71
    • Drzewiecki, G.1
  • 55
    • 85010182289 scopus 로고    scopus 로고
    • Imaging of tissue reperfusion by dy- namic optical tomography
    • Biomedical Topical Meetings, OSA Technical DigestOptical Society of America, Washington D.C
    • S. Blattman, H. L. Graber, S. Zheng, Y. Pei, J. Hira, I. Arif, and R. L. Barbour, “Imaging of tissue reperfusion by dy- namic optical tomography,” in Biomedical Topical Meetings, OSA Technical Digest (Optical Society of America, Washington D.C., 2000), pp. 409-410.
    • (2000) , pp. 409-410
    • Blattman, S.1    Graber, H.L.2    Zheng, S.3    Pei, Y.4    Hira, J.5    Arif, I.6    Barbour, R.L.7
  • 56
    • 85010136783 scopus 로고    scopus 로고
    • The role of the microcirculation in the treatment of malignant tumors: Facts and fiction
    • Blood Perfusion and Microenvironments of Human Tumors: Implications for Clinical Radiooncology, M. Molls and P. Vaupel, eds. (Springer-Verlag, Berlin
    • B. Endrich and P. Vaupel, “The role of the microcirculation in the treatment of malignant tumors: facts and fiction,” in Blood Perfusion and Microenvironments of Human Tumors: Implications for Clinical Radiooncology, M. Molls and P. Vaupel, eds. (Springer-Verlag, Berlin, 1998), pp. 19 39.
    • (1998) , pp. 19 39
    • Endrich, B.1    Vaupel, P.2
  • 57
    • 0030861562 scopus 로고    scopus 로고
    • Durchblutungsdiagnostik von Mammatumoren unter Blutdruckerhohung: Neue Moglichkeiten in der Dig- nitatsdiagnostik
    • C. Sohn, F. Beldermann, H. Frey, S. Reinhart, J. Sohn, and G. Bastert, “Durchblutungsdiagnostik von Mammatumoren unter Blutdruckerhohung: neue Moglichkeiten in der Dig- nitatsdiagnostik,” Radiologe 37, 643-650 (1997).
    • (1997) Radiologe , vol.37 , pp. 643-650
    • Sohn, C.1    Beldermann, F.2    Frey, H.3    Reinhart, S.4    Sohn, J.5    Bastert, G.6
  • 58
    • 0026692678 scopus 로고
    • The influence of different beta-blocking drugs on the pe- ripheral circulation in Raynaud’s phenomenon and in hy- pertension
    • C. Franssen, H. Wollershein, A. de Haan, and T. Thien, “The influence of different beta-blocking drugs on the pe- ripheral circulation in Raynaud’s phenomenon and in hy- pertension,”J. Clin. Pharm. 32, 652-659 (1992).
    • (1992) J. Clin. Pharm , vol.32 , pp. 652-659
    • Franssen, C.1    Wollershein, H.2    De Haan, A.3    Thien, T.4
  • 60
    • 0028318137 scopus 로고
    • Chaos and fractals in vascular biology
    • T. M. Griffith, “Chaos and fractals in vascular biology,” Vasc. Med. Rev. 5, 161 -182 (1994).
    • (1994) Vasc. Med. Rev. , vol.5
    • Griffith, T.M.1
  • 61
    • 36449001626 scopus 로고
    • Dy- namical disease: Identification, temporal aspects and treatment strategies of human illness
    • Chaos
    • J. Belair, L. Glass, U. an der Heiden, and J. Milton, “Dy- namical disease: identification, temporal aspects and treatment strategies of human illness,” Chaos 5, 1 -7 (1995).
    • (1995) , vol.5
    • Belair, J.1    Glass, L.2    An Der Heiden, U.3    Milton, J.4
  • 63
    • 0029979316 scopus 로고    scopus 로고
    • Short- and long-term variations in non- linear dynamics of heart rate variability
    • J. K. Kantors, M. V. Hojgaard, E. Agner, and N.-H. Holstein-Rathlou, “Short- and long-term variations in non- linear dynamics of heart rate variability,” Cardiovasc. Res. 31, 400-409 (1996).
    • (1996) Cardiovasc. Res. , vol.31 , pp. 400-409
    • Kantors, J.K.1    Hojgaard, M.V.2    Agner, E.3    Holstein-Rathlou, N.-H.4
  • 65
    • 0001218680 scopus 로고
    • Sléép and the suddén infant déath syndromé
    • Principles and Practice of Sleep Medicine in the Child, R. Férbér and M. H. Krygér, eds. (Saundérs, Philadélphia, Pa
    • S. F. Glotzbach, R. L. Ariagno, and R. M. Harper, “Sléép and the suddén infant déath syndromé,” in Principles and Practice of Sleep Medicine in the Child, R. Férbér and M. H. Krygér, eds. (Saundérs, Philadélphia, Pa., 1995), pp. 231 - 244.
    • (1995)
    • Glotzbach, S.F.1    Ariagno, R.L.2    Harper, R.M.3
  • 66
    • 0000289921 scopus 로고
    • On the évidéncé for low-dimensional chaos in an epileptic éléctroéncéphalogram
    • J. Théilér, “On the évidéncé for low-dimensional chaos in an epileptic éléctroéncéphalogram,” Phys. Létt. A 196, 334- 341 (1995).
    • (1995) Phys. Létt. , vol.196
    • Théilér, J.1
  • 67
    • 0028246442 scopus 로고
    • Heterogeneity of red blood cell perfusion in capillary networks supplied by a singlé artériolé in resting skélétal musclé
    • C. G. Ellis, S. M. Wrigley, and A. C. Groom, “Heterogeneity of red blood cell perfusion in capillary networks supplied by a singlé artériolé in resting skélétal musclé,” Circ. Res. 75, 357-368 (1994).
    • (1994) Circ. Res. , vol.75 , pp. 357-368
    • Ellis, C.G.1    Wrigley, S.M.2    Groom, A.C.3
  • 68
    • 0004273134 scopus 로고    scopus 로고
    • Positron-emission tomography (PET)
    • The Biomedical Engineering Hand- book, 2nd éd., J. D. Bronzino, éd. (CRC Press, Boca Raton, Fla., Chap. 67
    • T. F. Budinger and H. F. VanBrocklin, “Positron-emission tomography (PET),” in The Biomedical Engineering Hand- book, 2nd éd., J. D. Bronzino, éd. (CRC Press, Boca Raton, Fla., 2000), Chap. 67.
    • (2000)
    • Budinger, T.F.1    Vanbrocklin, H.F.2
  • 69
    • 85010097459 scopus 로고    scopus 로고
    • Nuclear mediciné
    • The Biomedical Engineering Handbook, 2nd éd., J. D. Bronzino, éd. (CRC Press, Boca Raton, Fla., Chap. 64
    • B. Y. Croft and B. M. W. Tsui, “Nuclear mediciné,” in The Biomedical Engineering Handbook, 2nd éd., J. D. Bronzino, éd. (CRC Press, Boca Raton, Fla., 2000), Chap. 64.
    • (2000)
    • Croft, B.Y.1    Tsui, B.M.W.2
  • 70
    • 85010172845 scopus 로고    scopus 로고
    • EEG and MEG imaging techniques have temporal resolutions sufficiéntly finé to respond to variations resulting from thé réspiratory and cardiac cyclés, but these aré lim- itéd to functional studies of thé brain; éven héré, théir pur- posé is to assess neuronal, not circulatory, function
    • EEG and MEG imaging techniques have temporal resolutions sufficiéntly finé to respond to variations resulting from thé réspiratory and cardiac cyclés, but these aré lim- itéd to functional studies of thé brain; éven héré, théir pur- posé is to assess neuronal, not circulatory, function.
  • 71
    • 0032498557 scopus 로고    scopus 로고
    • Timé-resolved and nonlinear optical imaging for medical applications
    • Advances in Optical Biopsy and Optical Mammography, Vol. 838 of thé Annals of thé New York Academy of Sciences (New York Academy of Sciences, New York
    • R. R. Alfano, S. G. Demos, P. Galland, S. K. Gayen, Y. Guo, P. P. Ho, X. Liang, F. Liu, L. Wang, Q. Z. Wang, and W. B. Wang, “Timé-resolved and nonlinear optical imaging for medical applications,” in Advances in Optical Biopsy and Optical Mammography, Vol. 838 of thé Annals of thé New York Academy of Sciences (New York Academy of Sciences, New York, 1998), pp. 14-27.
    • (1998) , pp. 14-27
    • Alfano, R.R.1    Demos, S.G.2    Galland, P.3    Gayen, S.K.4    Guo, Y.5    Ho, P.P.6    Liang, X.7    Liu, F.8    Wang, L.9    Wang, Q.Z.10    Wang, W.B.11
  • 72
    • 0031288609 scopus 로고    scopus 로고
    • Thé UCL multichannél timé-resolved systém for optical tomography
    • Optical Tomography and Spectroscopy of Tissue: Theory, Instrumentation, Model, and Human Studies II, B. Chance and R. R. Alfano, éds., Proc. SPIE 2979
    • K. Wells, J. C. Hebden, F. E. W. Schmidt, and D. T. Delpy, “Thé UCL multichannél timé-resolved systém for optical tomography,” in Optical Tomography and Spectroscopy of Tissue: Theory, Instrumentation, Model, and Human Studies II, B. Chance and R. R. Alfano, éds., Proc. SPIE 2979, 599607 (1997).
    • (1997) , pp. 599607
    • Wells, K.1    Hebden, J.C.2    Schmidt, F.E.W.3    Delpy, D.T.4
  • 73
    • 0001605698 scopus 로고    scopus 로고
    • Nonuniqueness in diffusion-baséd optical tomography
    • S. R. Arridgé and W. R. B. Lionhéart, “Nonuniqueness in diffusion-baséd optical tomography,” Opt. Létt. 23, 882-884 (1998).
    • (1998) Opt. Létt. , vol.23 , pp. 882-884
    • Arridgé, S.R.1    Lionhéart, W.R.B.2
  • 74
    • 0026958584 scopus 로고
    • Principal component analysis and éxploratory factor analysis
    • I. T. Joliffé and B. J. T. Morgan, “Principal component analysis and éxploratory factor analysis,” Stat. Méth. Méd. Res. 1, 69-95 (1992).
    • (1992) Stat. Méth. Méd. Res. , vol.1 , pp. 69-95
    • Joliffé, I.T.1    Morgan, B.J.T.2
  • 75
    • 0031880096 scopus 로고    scopus 로고
    • An évaluation of linear modél analysis téchniques for processing imagés of microcirculation activity
    • J. Mayhéw, D. Hu, Y. Zhéng, S. Askéw, Y. Hou, J. Bérwick, P. J. Cofféy, and N. Brown, “An évaluation of linear modél analysis téchniques for processing imagés of microcirculation activity,” Néuroimagé 7, 49-71 (1998).
    • (1998) Néuroimagé , vol.7 , pp. 49-71
    • Mayhéw, J.1    Hu, D.2    Zhéng, Y.3    Askéw, S.4    Hou, Y.5    Bérwick, J.6    Cofféy, P.J.7    Brown, N.8
  • 76
    • 0002081583 scopus 로고    scopus 로고
    • High spééd optical tomography systém for imaging dy- namic transparent media
    • http://www.opticsexpress.org
    • L. McMackin, R. J. Hugo, R. E. Piérson, and C. R. Truman, “High spééd optical tomography systém for imaging dy- namic transparent media,” Opt. Express 1, 302-311 (1997). http://www.opticsexpress.org.
    • (1997) Opt. Express , vol.1 , pp. 302-311
    • McMackin, L.1    Hugo, R.J.2    Piérson, R.E.3    Truman, C.R.4
  • 77
    • 85010178389 scopus 로고    scopus 로고
    • Whilé addition of a spectral windowing operation to the time-series analysis would likely yield better frequency resolution than that séén in this figuré, noné was actually used whilé thé results presentéd in this report were béing generated
    • Whilé addition of a spectral windowing operation to the time-series analysis would likely yield better frequency resolution than that séén in this figuré, noné was actually used whilé thé results presentéd in this report were béing generated.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.