메뉴 건너뛰기




Volumn 133, Issue , 2001, Pages 119-130

Computerized selection of membranes and hemodialysers

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL MEMBRANE; COMPUTER; COMPUTER SIMULATION; DATA BASE; HUMAN; INSTRUMENTATION; RENAL REPLACEMENT THERAPY; REVIEW; THEORETICAL MODEL;

EID: 0035534291     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/000060118     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0001682993 scopus 로고
    • Development of a parallel-flow artificial kidney in plastics
    • Kiil F: Development of a parallel-flow artificial kidney in plastics. Acta Chir Scand 1960;253(suppl):S142-S146.
    • (1960) Acta Chir Scand , vol.253 , Issue.SUPPL.
    • Kiil, F.1
  • 2
  • 3
    • 0001271447 scopus 로고
    • Further development of a coil kidney
    • Kolff VJ, Watshinger B: Further development of a coil kidney. J Lab Clin Med 1956;7:969-974.
    • (1956) J Lab Clin Med , vol.7 , pp. 969-974
    • Kolff, V.J.1    Watshinger, B.2
  • 4
    • 0002086589 scopus 로고
    • Development of flat type hollow-fibre dialyzer (NF-01) achievement of better performance than cylinder type with same membrane area
    • Frost TH (ed): Tunbridge Wells, Pitman Medical
    • Nakagawa S, Koshikawa S, Ishida Y, Uematsu M, Ishibashi K: Development of flat type hollow-fibre dialyzer (NF-01) achievement of better performance than cylinder type with same membrane area; in Frost TH (ed): Technical Aspects of Renal Dialysis. Tunbridge Wells, Pitman Medical, 1977, pp 29-37.
    • (1977) Technical Aspects of Renal Dialysis , pp. 29-37
    • Nakagawa, S.1    Koshikawa, S.2    Ishida, Y.3    Uematsu, M.4    Ishibashi, K.5
  • 5
    • 0023693388 scopus 로고
    • Hollow fiber dialyzers on the market
    • Sigdell JE: Hollow fiber dialyzers on the market. Artif Organs 1988;12:4-11.
    • (1988) Artif Organs , vol.12 , pp. 4-11
    • Sigdell, J.E.1
  • 6
    • 0002948569 scopus 로고
    • Comparison of the hollow dialyzers
    • Sigdell JE: Comparison of the hollow dialyzers. Artif Organs 1981;5:4-9.
    • (1981) Artif Organs , vol.5 , pp. 4-9
    • Sigdell, J.E.1
  • 8
    • 0022061168 scopus 로고
    • Theoretical assessment of the effect of flow maldistributions on the mass transfer efficiency of artificial organs
    • Van der Velde C, Leonard EF: Theoretical assessment of the effect of flow maldistributions on the mass transfer efficiency of artificial organs. Med Biol Eng Comput 1985;23:224-229.
    • (1985) Med Biol Eng Comput , vol.23 , pp. 224-229
    • Van Der Velde, C.1    Leonard, E.F.2
  • 9
    • 0002900526 scopus 로고    scopus 로고
    • Dialyzers evaluation
    • Winchester J, Koch K, Jacobs C, Kjellestrand C (eds): Dordrecht, Kluwer Academic
    • Hoenich N, Ronco C: Dialyzers evaluation; in Winchester J, Koch K, Jacobs C, Kjellestrand C (eds): Replacement of Renal Function by Dialysis. Dordrecht, Kluwer Academic, 1996, pp 256-270.
    • (1996) Replacement of Renal Function by Dialysis , pp. 256-270
    • Hoenich, N.1    Ronco, C.2
  • 12
    • 0027420449 scopus 로고
    • Technical and clinical evaluation of a new asymmetric polysulfone membrane (Biosulfane)
    • Ronco C, Brendolan A, Crepaldi C, et al: Technical and clinical evaluation of a new asymmetric polysulfone membrane (Biosulfane). Int J Artif Organs 1993;8:573-584.
    • (1993) Int J Artif Organs , vol.8 , pp. 573-584
    • Ronco, C.1    Brendolan, A.2    Crepaldi, C.3
  • 13
    • 0026578788 scopus 로고
    • A new scintigraphic method to characterize ultrafiltration in hollow-fiber dialyzers
    • Ronco C, Brendolan A, Feriani M, et al: A new scintigraphic method to characterize ultrafiltration in hollow-fiber dialyzers. Kidney Int 1992;41:1383-1393.
    • (1992) Kidney Int , vol.41 , pp. 1383-1393
    • Ronco, C.1    Brendolan, A.2    Feriani, M.3
  • 14
    • 0033803749 scopus 로고    scopus 로고
    • New developments in hemodialyzers
    • Ronco C, Ballestri M: New developments in hemodialyzers. Blood Purif 2000;18:267-275.
    • (2000) Blood Purif , vol.18 , pp. 267-275
    • Ronco, C.1    Ballestri, M.2
  • 15
    • 0030873353 scopus 로고    scopus 로고
    • Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance
    • Ronco C, Scabardi M, Goldoni M, Brendolan A, Crepaldi C, La Greca G: Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance. Int J Artif Organs 1997;5:261-266.
    • (1997) Int J Artif Organs , vol.5 , pp. 261-266
    • Ronco, C.1    Scabardi, M.2    Goldoni, M.3    Brendolan, A.4    Crepaldi, C.5    La Greca, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.