메뉴 건너뛰기




Volumn 26, Issue 21, 2001, Pages 2328-2333

Pedicle screw adjustments affect stability of thoracolumbar burst fracture

Author keywords

Biomechanics; Burst fracture; Device adjustment; Pedicle screw fixation; Spinal stability

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE SCREW; CADAVER; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; JOINT STABILITY; MALE; PRIORITY JOURNAL; SPINE STABILIZATION; THORACOLUMBAR SPINE; VERTEBRA FRACTURE;

EID: 0035500054     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-200111010-00008     Document Type: Article
Times cited : (16)

References (24)
  • 1
    • 0023626715 scopus 로고
    • Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system: Indications, techniques, and first results of treatment
    • (1987) Spine , vol.12 , pp. 544-551
    • Aebi, M.1    Etter, C.2    Kehl, T.3
  • 3
    • 0021059058 scopus 로고
    • The three-column spine and its significance in the classification of acute thoracolumbar spine injuries
    • (1983) Spine , vol.8 , pp. 817-831
    • Denis, F.1
  • 9
    • 0031053102 scopus 로고    scopus 로고
    • Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model
    • (1997) Spine , vol.22 , pp. 261-266
    • Lim, T.H.1    An, H.S.2    Hong, J.W.3
  • 10
    • 0026024322 scopus 로고
    • The fixator interne in the reduction and stabilization of thoracolumbar spine fractures in patients with neuralgic deficit
    • (1991) Spine , vol.16 , Issue.SUPPL. , pp. 140-145
    • Lindsey, R.W.1    Dick, W.2
  • 13
    • 0021906626 scopus 로고
    • Lumbar spine instability: A clinical update and symposium summary
    • (1985) Spine , vol.10 , pp. 290-291
    • Nachemson, A.1
  • 14
    • 0019969097 scopus 로고
    • Physiological strains in lumbar spinal ligaments, an in vitro biomechanical study: 1981 Volvo award in biomechanics
    • (1982) Spine , vol.7 , pp. 192-203
    • Panjabi, M.M.1    Goel, V.K.2    Takata, K.3
  • 19
    • 0032527436 scopus 로고    scopus 로고
    • Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine
    • (1998) Spine , vol.23 , pp. 1550-1558
    • Shono, Y.1    Kaneda, K.2    Abumi, K.3
  • 20
    • 0027944542 scopus 로고
    • Experimental study of thoracolumbar burst fractures: A radiographic and biomechanical analysis of anterior and posterior instrumentation systems
    • (1994) Spine , vol.19 , pp. 1711-1722
    • Shono, Y.1    McAfee, P.C.2    Cunningham, B.W.3
  • 22
    • 0029609525 scopus 로고
    • Internal fixation (pedicle screw fixation) for fusions of the lumbar spine
    • (1995) Spine , vol.20 , Issue.SUPPL. , pp. 157-165
    • Vaccaro, A.R.1    Garfin, S.R.2
  • 24
    • 0027414838 scopus 로고
    • Mechanics of anatomic reduction of thoracolumbar burst fractures comparison of distraction versus distraction plus lordosis, in the anatomic reduction of the thoracolumbar burst fracture
    • (1993) Spine , vol.18 , pp. 195-203
    • Zou, D.1    Yoo, J.U.2    Edwards, W.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.