메뉴 건너뛰기




Volumn 122, Issue 4, 2001, Pages 786-787

Circulatory support with a direct cardiac compression device: A less invasive approach with the AbioBooster device

Author keywords

[No Author keywords available]

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; ESMOLOL; NORADRENALIN; POLITEF; POLYURETHAN; SILICONE;

EID: 0035497317     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1067/mtc.2001.115929     Document Type: Article
Times cited : (15)

References (8)
  • 2
    • 0027525086 scopus 로고
    • Evaluation of bioprosthetic valve-associated thrombus in ventricular assist device patients
    • Wagner WR, Johnson PC, Kormos RL, Griffith P. Evaluation of bioprosthetic valve-associated thrombus in ventricular assist device patients. Circulation. 1993;88:2023-9.
    • (1993) Circulation , vol.88 , pp. 2023-2029
    • Wagner, W.R.1    Johnson, P.C.2    Kormos, R.L.3    Griffith, P.4
  • 3
    • 0002672492 scopus 로고
    • A new instrument for prolonged mechanical massage
    • Anstadt GL, Baltimore WS, Baue AE. A new instrument for prolonged mechanical massage [abstract]. Circulation. 1965;31(Suppl):II-43.
    • (1965) Circulation , vol.31 , Issue.SUPPL.
    • Anstadt, G.L.1    Baltimore, W.S.2    Baue, A.E.3
  • 4
    • 0030894978 scopus 로고    scopus 로고
    • Bridge experience with long-term implantable left ventricular assist devices: Are they an alternative to transplantation?
    • Oz MC, Argenziano M, Catanese KA, Gardocki MT, Goldstein DJ, Ashton RC, et al. Bridge experience with long-term implantable left ventricular assist devices: Are they an alternative to transplantation? Circulation. 1997;95:1844-52.
    • (1997) Circulation , vol.95 , pp. 1844-1852
    • Oz, M.C.1    Argenziano, M.2    Catanese, K.A.3    Gardocki, M.T.4    Goldstein, D.J.5    Ashton, R.C.6
  • 5
    • 1842364940 scopus 로고    scopus 로고
    • Vascular complications related to intraaortic balloon counterpulsation: An analysis of ten years experience
    • Busch T, Sirbu H, Zenker D, Dalichau H. Vascular complications related to intraaortic balloon counterpulsation: an analysis of ten years experience. Thorac Cardiovasc Surg. 1997;45:55-9.
    • (1997) Thorac Cardiovasc Surg , vol.45 , pp. 55-59
    • Busch, T.1    Sirbu, H.2    Zenker, D.3    Dalichau, H.4
  • 7
    • 0025812189 scopus 로고
    • Direct mechanical ventricular actuation for cardiac arrest in humans: A clinical feasibility trial
    • Anstadt MP, Bartlett RL, Malone JP, Brown GR, Martin S, Nolan DJ, et al. Direct mechanical ventricular actuation for cardiac arrest in humans: a clinical feasibility trial. Chest. 1991;100:86-92.
    • (1991) Chest , vol.100 , pp. 86-92
    • Anstadt, M.P.1    Bartlett, R.L.2    Malone, J.P.3    Brown, G.R.4    Martin, S.5    Nolan, D.J.6
  • 8
    • 0026409365 scopus 로고
    • First successful bridge to cardiac transplantation using direct mechanical ventricular actuation
    • Lowe JE, Anstadt MP, Van Trigt P, Smith PK, Hendry PJ, Plunkett MD, et al. First successful bridge to cardiac transplantation using direct mechanical ventricular actuation. Ann Thorac Surg. 1991;52: 1237-43.
    • (1991) Ann Thorac Surg , vol.52 , pp. 1237-1243
    • Lowe, J.E.1    Anstadt, M.P.2    Van Trigt, P.3    Smith, P.K.4    Hendry, P.J.5    Plunkett, M.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.