Indirect position sensing of SRM on the basis of simplified flux method

Author keywords

Indirect position detecting; Position sensorless SRM; Simplified flux method

Indexed keywords

CURRENT DENSITY; INDUCTANCE MEASUREMENT; LEARNING ALGORITHMS; MAGNETIC FLUX; POSITION MEASUREMENT; ROTORS;

EID: 0035494151     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (49)

References (10)
  • 4
    • 0028427371 scopus 로고
    • Rotor position sensing in switched reluctance motor drives by Measuring Mutually induced voltages
    • (1994) IEEE Transaction on IA , vol.30 , Issue.3 , pp. 665-672
    • Husain, I.1
  • 6
    • 0030234511 scopus 로고    scopus 로고
    • Application of a full-order extended Luenberger observer for a position sensorless operation of a switched reluctance motor drive
    • (1996) IEE Proc. - Control Theory Appl. , vol.143 , Issue.5 , pp. 401-408
    • Elmas, C.1