메뉴 건너뛰기




Volumn 19, Issue 8, 2001, Pages 1125-1128

On the effects of gating in diffusion imaging of the brain using single shot EPI

Author keywords

Artifacts; Cardiac gating; Diffusion tensor imaging; Magnetic resonance imaging; Triggering

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; BRAIN RADIOGRAPHY; BRAIN REGION; BRAIN SLICE; CORPUS CALLOSUM; DIAGNOSTIC IMAGING; DIFFUSION TENSOR IMAGING; FEMALE; HEART CYCLE; HEMODYNAMICS; HUMAN; MALE; MEASUREMENT; MOTION; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RR INTERVAL; SIGNAL NOISE RATIO; TIME SERIES ANALYSIS; ARTIFACT; BRAIN; ECHO PLANAR IMAGING; HEART; METHODOLOGY; PHYSIOLOGY; PULSE RATE; TIME;

EID: 0035488291     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(01)00415-5     Document Type: Article
Times cited : (134)

References (15)
  • 1
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med 1999;42:515-25.
    • (1999) Magn Reson Med , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 2
    • 0034567198 scopus 로고    scopus 로고
    • Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI
    • Skare S, Hedehus M, Moseley ME, Li TQ. Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI. J Magn Reson 2000;147:340-52.
    • (2000) J Magn Reson , vol.147 , pp. 340-352
    • Skare, S.1    Hedehus, M.2    Moseley, M.E.3    Li, T.Q.4
  • 3
    • 0034001139 scopus 로고    scopus 로고
    • Reducing motion artefacts in diffusion-weighted MRI of the brain: Efficacy of navigator echo correction and pulse triggering
    • Dietrich O, Heiland S, Benner T, Sartor K. Reducing motion artefacts in diffusion-weighted MRI of the brain: efficacy of navigator echo correction and pulse triggering. Neuroradiology 2000;42:85-91.
    • (2000) Neuroradiology , vol.42 , pp. 85-91
    • Dietrich, O.1    Heiland, S.2    Benner, T.3    Sartor, K.4
  • 6
    • 0025881159 scopus 로고
    • Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imaging
    • Chenevert TL, Pipe JG. Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imaging. Magn Reson Med 1991;19:261-5.
    • (1991) Magn Reson Med , vol.19 , pp. 261-265
    • Chenevert, T.L.1    Pipe, J.G.2
  • 8
    • 0033870313 scopus 로고    scopus 로고
    • High-resolution diffusion imaging using phase-corrected segmented echoplanar imaging
    • Brockstedt S, Moore JR, Thomsen C, Holtas S, Stahlberg F. High-resolution diffusion imaging using phase-corrected segmented echoplanar imaging. Magn Reson Imaging 2000;18:649-57.
    • (2000) Magn Reson Imaging , vol.18 , pp. 649-657
    • Brockstedt, S.1    Moore, J.R.2    Thomsen, C.3    Holtas, S.4    Stahlberg, F.5
  • 9
    • 0030090119 scopus 로고    scopus 로고
    • Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging
    • Wirestam R, Greitz D, Thomsen C, Brockstedt S, Olsson MB, Stahlberg F. Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging. J Magn Reson Imaging 1996;6:348-55.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 348-355
    • Wirestam, R.1    Greitz, D.2    Thomsen, C.3    Brockstedt, S.4    Olsson, M.B.5    Stahlberg, F.6
  • 10
    • 0030895325 scopus 로고    scopus 로고
    • Quantification of low-velocity motion using a navigator-echo supported MR velocity-mapping technique: Application to intracranial dynamics in volunteers and patients with brain tumours
    • Wirestam R, Salford LG, Thomsen C, Brockstedt S, Persson BR, Stahlberg F. Quantification of low-velocity motion using a navigator-echo supported MR velocity-mapping technique: application to intracranial dynamics in volunteers and patients with brain tumours. Magn Reson Imaging 1997;15:1-11.
    • (1997) Magn Reson Imaging , vol.15 , pp. 1-11
    • Wirestam, R.1    Salford, L.G.2    Thomsen, C.3    Brockstedt, S.4    Persson, B.R.5    Stahlberg, F.6
  • 13
    • 0000069203 scopus 로고    scopus 로고
    • Image registration
    • BPA Moonen CTW, editor. Berlin: Springer-Verlag
    • Ashburner J FKJ. Image Registration. In: BPA Moonen CTW, editor. Functional MRI. Berlin: Springer-Verlag, 1999, p. 285-99.
    • (1999) Functional MRI , pp. 285-299
    • Ashburner, J.F.K.J.1
  • 15
    • 0032970425 scopus 로고    scopus 로고
    • Nonlinear spatial normalization using basis functions
    • Ashburner J FKJ. Nonlinear spatial normalization using basis functions. Human Brain Mapping 1999;7:254-66.
    • (1999) Human Brain Mapping , vol.7 , pp. 254-266
    • Ashburner, J.F.K.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.