메뉴 건너뛰기




Volumn 9, Issue 5, 2001, Pages 302-306

Inter- and intratester comparison of the Rolimeter knee tester: Effect of tester's experience and the examination technique

Author keywords

Anterior cruciate ligament deficiency; Anterior tibial displacement; Anterior tibial translation; Measuring devices; Rolimeter knee tester

Indexed keywords

ADULT; ANTERIOR CRUCIATE LIGAMENT; ARTICLE; CLINICAL COMPETENCE; COMPARATIVE STUDY; FEMALE; HUMAN; INSTRUMENTATION; JOINT INSTABILITY; MALE; OBSERVER VARIATION; PATHOPHYSIOLOGY; PHYSICAL EXAMINATION; REPRODUCIBILITY;

EID: 0035463279     PISSN: 09422056     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001670100225     Document Type: Article
Times cited : (60)

References (25)
  • 2
    • 0032605067 scopus 로고    scopus 로고
    • Evaluation of anterior knee joint instability with the Rolimeter. A test in comparison with manual assessment and measuring with the KT-1000 arthrometer
    • Balasch H, Schiller M, Friebel H, Hoffmann F (1999) Evaluation of anterior knee joint instability with the Rolimeter. A test in comparison with manual assessment and measuring with the KT-1000 arthrometer. Knee Surg Sports Traumatol Arthrosc 74:204-208
    • (1999) Knee Surg Sports Traumatol Arthrosc , vol.74 , pp. 204-208
    • Balasch, H.1    Schiller, M.2    Friebel, H.3    Hoffmann, F.4
  • 3
    • 0028879131 scopus 로고
    • Influence of examiner experience and gender on interrater reliability of KT-1000 arthrometer measurements
    • Ballantyne BT, French AK, Heimsoth SL, Kachingwe AF, Lee JB, Soderberg GL (1995) Influence of examiner experience and gender on interrater reliability of KT-1000 arthrometer measurements. Phys Ther 7510:898-906
    • (1995) Phys Ther , vol.7510 , pp. 898-906
    • Ballantyne, B.T.1    French, A.K.2    Heimsoth, S.L.3    Kachingwe, A.F.4    Lee, J.B.5    Soderberg, G.L.6
  • 5
    • 0022359624 scopus 로고
    • Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption
    • Daniel DM, Stone ML, Sachs R, Malcom L (1985) Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption. Am J Sports Med 136:401-407
    • (1985) Am J Sports Med , vol.136 , pp. 401-407
    • Daniel, D.M.1    Stone, M.L.2    Sachs, R.3    Malcom, L.4
  • 6
    • 0028306075 scopus 로고
    • Comparative measurements of anterior tibial translation using the KT- 1000 knee arthrometer with the leg in neutral, internal rotation, and external rotation
    • Fiebert I, Gresley J, Hoffman S, Kunkel K (1994) Comparative measurements of anterior tibial translation using the KT-1000 knee arthrometer with the leg in neutral, internal rotation, and external rotation. J Orthop Sports Phys Ther 196:331-334
    • (1994) J Orthop Sports Phys Ther , vol.196 , pp. 331-334
    • Fiebert, I.1    Gresley, J.2    Hoffman, S.3    Kunkel, K.4
  • 8
    • 0023101025 scopus 로고
    • Reliability of measuring anterior laxity of the knee joint using a knee ligament arthrometer
    • Hanten WP, Pace MB (1987) Reliability of measuring anterior laxity of the knee joint using a knee ligament arthrometer. Phys Ther 67:357-359
    • (1987) Phys Ther , vol.67 , pp. 357-359
    • Hanten, W.P.1    Pace, M.B.2
  • 9
    • 0029837156 scopus 로고    scopus 로고
    • Cruciate ligament injuries with knee joint effusion-why can the Lachman sign not be elicited?
    • Hopf T, Gleitz M, Rupp S, Muller B (1996) Cruciate ligament injuries with knee joint effusion-why can the Lachman sign not be elicited? Z Orthop Ihre Grenzgeb 1345:418-421
    • (1996) Z Orthop Ihre Grenzgeb , vol.1345 , pp. 418-421
    • Hopf, T.1    Gleitz, M.2    Rupp, S.3    Muller, B.4
  • 10
    • 0030872158 scopus 로고    scopus 로고
    • Intratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee
    • Huber FE, Irrgang JJ, Harner C, Lephart S (1997) Intratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee. Am J Sports Med 254:479-485
    • (1997) Am J Sports Med , vol.254 , pp. 479-485
    • Huber, F.E.1    Irrgang, J.J.2    Harner, C.3    Lephart, S.4
  • 11
    • 0027422022 scopus 로고
    • Laxity after cruciate ligament injury in 94 knees. The KT-1000 arthrometer versus roentgen stereophotogrammetry
    • Jonsson H, Karrholm J, Elmqvist LG (1993) Laxity after cruciate ligament injury in 94 knees. The KT-1000 arthrometer versus roentgen stereophotogrammetry. Acta Orthop Scand 645:567-570
    • (1993) Acta Orthop Scand , vol.645 , pp. 567-570
    • Jonsson, H.1    Karrholm, J.2    Elmqvist, L.G.3
  • 12
    • 0031596550 scopus 로고    scopus 로고
    • Diagnosis of anterior knee instability. Comparison between the Lachman test, the KT-1:000 arthrometer and the ultrasound Lachman test
    • Konig DP, Rutt J, Kumm D, Breidenbach E (1998) Diagnosis of anterior knee instability. Comparison between the Lachman test, the KT-1:000 arthrometer and the ultrasound Lachman test. Unfallchirurg 1013:209-213
    • (1998) Unfallchirurg , vol.1013 , pp. 209-213
    • Konig, D.P.1    Rutt, J.2    Kumm, D.3    Breidenbach, E.4
  • 13
    • 0027321299 scopus 로고
    • Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer
    • Kowalk DL, Wojtys EM, Disher J, Loubert P (1993) Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer. Am J Sports Med 215:744-747
    • (1993) Am J Sports Med , vol.215 , pp. 744-747
    • Kowalk, D.L.1    Wojtys, E.M.2    Disher, J.3    Loubert, P.4
  • 14
    • 0027899387 scopus 로고
    • A comparison of pre-operative evaluation of anterior knee laxity by dynamic X-rays and by the arthrometer KT 1000
    • Lerat JL, Moyen B, Jenny JY, Perrier JP (1993) A comparison of pre-operative evaluation of anterior knee laxity by dynamic X-rays and by the arthrometer KT 1000. Knee Surg Sports Traumatol Arthrosc 11:54-59
    • (1993) Knee Surg Sports Traumatol Arthrosc , vol.11 , pp. 54-59
    • Lerat, J.L.1    Moyen, B.2    Jenny, J.Y.3    Perrier, J.P.4
  • 15
    • 0033089226 scopus 로고    scopus 로고
    • The effect of knee effusions on KT-1000 arthrometry: A cadaver study
    • Muellner T (1999) The effect of knee effusions on KT-1000 arthrometry: A cadaver study. Am J Sports Med 272:266-267
    • (1999) Am J Sports Med , vol.272 , pp. 266-267
    • Muellner, T.1
  • 16
    • 0033090924 scopus 로고    scopus 로고
    • The effect of knee effusions on KT-1000 arthrometry
    • Rangger C, Klestil T (1999) The effect of knee effusions on KT-1000 arthrometry. Am J Sports Med 272:267
    • (1999) Am J Sports Med , vol.272 , pp. 267
    • Rangger, C.1    Klestil, T.2
  • 17
    • 0028889994 scopus 로고
    • Intertester reliability of measurements obtained with the KT-1000 on patients with reconstructed anterior cruciate ligaments
    • Robnett NJ, Riddle DL, Kues JM (1995) Intertester reliability of measurements obtained with the KT-1000 on patients with reconstructed anterior cruciate ligaments. J Orthop Sports Phys Ther 212:113-119
    • (1995) J Orthop Sports Phys Ther , vol.212 , pp. 113-119
    • Robnett, N.J.1    Riddle, D.L.2    Kues, J.M.3
  • 18
    • 0023100176 scopus 로고
    • Measurements of anterior laxity in normal and anterior cruciate absent knees with two instrumented test devices
    • Sherman OH, Markolf KL, Ferkel RD (1987) Measurements of anterior laxity in normal and anterior cruciate absent knees with two instrumented test devices. Clin Orthop 215:156-161
    • (1987) Clin Orthop , vol.215 , pp. 156-161
    • Sherman, O.H.1    Markolf, K.L.2    Ferkel, R.D.3
  • 19
    • 0025760231 scopus 로고
    • Anterior knee motion analysis. Measurement and simultaneous radiography
    • Staubli HU, Jakob RP (1991) Anterior knee motion analysis. Measurement and simultaneous radiography. Am J Sports Med 192:172-177
    • (1991) Am J Sports Med , vol.192 , pp. 172-177
    • Staubli, H.U.1    Jakob, R.P.2
  • 20
    • 0028836107 scopus 로고
    • Clinical tests versus KT-1000 instrumented laxity test in acute anterior cruciate ligament tears
    • Strand T, Solheim E (1995) Clinical tests versus KT-1000 instrumented laxity test in acute anterior cruciate ligament tears. Int J Sports Med 161:51-53
    • (1995) Int J Sports Med , vol.161 , pp. 51-53
    • Strand, T.1    Solheim, E.2
  • 21
    • 0017066289 scopus 로고
    • Clinical diagnosis of anterior cruciate ligament instability in the athlete
    • Torg JS, Conrad W, Kalen V (1976) Clinical diagnosis of anterior cruciate ligament instability in the athlete. Am J Sports Med 4:84-91
    • (1976) Am J Sports Med , vol.4 , pp. 84-91
    • Torg, J.S.1    Conrad, W.2    Kalen, V.3
  • 23
    • 0027499272 scopus 로고
    • The knee arthrometer KT-1000: Value of instrumental measurement in diagnosis of complex anterior knee instability
    • Werlich T, Brand H, Echtermeyer V, Pohlmann J (1993) The knee arthrometer KT-1000: value of instrumental measurement in diagnosis of complex anterior knee instability. Aktuelle Traumatol 231:43-49
    • (1993) Aktuelle Traumatol , vol.231 , pp. 43-49
    • Werlich, T.1    Brand, H.2    Echtermeyer, V.3    Pohlmann, J.4
  • 24
    • 0031819145 scopus 로고    scopus 로고
    • The effect of knee effusions on KT-1000 arthrometry. A cadaver study
    • Wright RW, Luhmann SJ (1998) The effect of knee effusions on KT-1000 arthrometry. A cadaver study. Am J Sports Med 264:571-574
    • (1998) Am J Sports Med , vol.264 , pp. 571-574
    • Wright, R.W.1    Luhmann, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.