메뉴 건너뛰기




Volumn 32, Issue SUPPL.2, 2001, Pages

Observations concerning different patterns of bone healing using the Point Contact Fixator (PC-Fix) as a new technique for fracture fixation

Author keywords

Biological osteosynthesis; Bone healing; Point Contact Fixator (PC Fix)

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BONE SCREW; CALLUS; CHI SQUARE DISTRIBUTION; FEMALE; FRACTURE HEALING; FRACTURE NONUNION; HUMAN; MALE; METHODOLOGY; OPEN FRACTURE; OSTEOSYNTHESIS; PATHOPHYSIOLOGY; PHYSIOLOGY; PROSTHESIS FAILURE; RADIOGRAPHY; RADIUS FRACTURE; RETROSPECTIVE STUDY; STAPHYLOCOCCUS INFECTION; ULNA FRACTURE; WOUND INFECTION;

EID: 0035462067     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0020-1383(01)00122-x     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0027958880 scopus 로고
    • Die biologische Plattenosteosynthese
    • Gautier E, Ganz R. Die biologische Plattenosteosynthese. Zentralbl Chir 1994;119:564-572.
    • (1994) Zentralbl Chir , vol.119 , pp. 564-572
    • Gautier, E.1    Ganz, R.2
  • 2
    • 0026333014 scopus 로고
    • The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP)
    • Perren S. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Injury 1991;22(S1):1-41.
    • (1991) Injury , vol.22 , Issue.S1 , pp. 1-41
    • Perren, S.1
  • 3
    • 0027179770 scopus 로고
    • Bone healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression
    • Aro HAT, Chao EYS. Bone healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin. Othop. 1993;293:8-17.
    • (1993) Clin. Othop. , vol.293 , pp. 8-17
    • Aro, H.A.T.1    Chao, E.Y.S.2
  • 5
    • 0031469963 scopus 로고    scopus 로고
    • The evolution of modern plate osteosynthesis
    • Miclau T, Martin RE. The evolution of modern plate osteosynthesis. Injury 1997;28(S1): A3-A6.
    • (1997) Injury , vol.28 , Issue.S1
    • Miclau, T.1    Martin, R.E.2
  • 6
    • 0028885138 scopus 로고
    • The biomechanics of the PC-Fix internal fixator
    • Tepic S, Perren SM. The biomechanics of the PC-Fix internal fixator. Injury 1995;26(S2):S-B51-S-B56.
    • (1995) Injury , vol.26 , Issue.S2
    • Tepic, S.1    Perren, S.M.2
  • 7
    • 0028808678 scopus 로고
    • Basic concepts relevant to the design and development of the Point Contact Fixator (PC-Fix)
    • Perren SM, Buchanan JS. Basic concepts relevant to the design and development of the Point Contact Fixator (PC-Fix). Injury 1995;26(S2):S-B1-S-B4.
    • (1995) Injury , vol.26 , Issue.S2
    • Perren, S.M.1    Buchanan, J.S.2
  • 8
    • 0030636125 scopus 로고    scopus 로고
    • Strength recovery in fractured sheep tibia treated with a plate or an internal fixator: An experimental study with a two-year follow-up
    • Tepic S, Remiger AR, Morikawa K, Predieri M, Perren S. Strength recovery in fractured sheep tibia treated with a plate or an internal fixator: An experimental study with a two-year follow-up. J. Orthop. Trauma 1997;11 (No. 1):14-23.
    • (1997) J. Orthop. Trauma , vol.11 , Issue.1 , pp. 14-23
    • Tepic, S.1    Remiger, A.R.2    Morikawa, K.3    Predieri, M.4    Perren, S.5
  • 9
    • 0028844609 scopus 로고
    • Finite Element Analysis (FEA) for the Point Contact Fixator. Screw drive, plate design, overcuts
    • Bresina SJ, Tepic S. Finite Element Analysis (FEA) for the Point Contact Fixator. Screw drive, plate design, overcuts. Injury 1995; 26 (S2):S-B20-S-B23.
    • (1995) Injury , vol.26 , Issue.S2
    • Bresina, S.J.1    Tepic, S.2
  • 11
    • 0017076151 scopus 로고
    • Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones
    • Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. J. Bone Joint Surg. (Am) 1976;58A:453-458.
    • (1976) J. Bone Joint Surg. (Am) , vol.58 A , pp. 453-458
    • Gustilo, R.B.1    Anderson, J.T.2
  • 12
    • 0000743143 scopus 로고    scopus 로고
    • Biological internal fixation of fractures: The balance between biology and mechanics. European Federation of National Associations of Orthopaedics and Traumatology (EFORT)
    • Kenwright J, Duparc J, Fulford P, eds. The British Editorial Society of Bone and Joint Surgery
    • Perren S, Ganz R. Biological internal fixation of fractures: The balance between biology and mechanics. European Federation of National Associations of Orthopaedics and Traumatology (EFORT). In: Kenwright J, Duparc J, Fulford P, eds. European Instructional Course Lectures. Vol. 3. The British Editorial Society of Bone and Joint Surgery, 1997:161-163.
    • (1997) European Instructional Course Lectures , vol.3 , pp. 161-163
    • Perren, S.1    Ganz, R.2
  • 13
    • 10644235521 scopus 로고    scopus 로고
    • Biomechanik der Frakturheilung. Übersicht über das Zusammenspiel von Biologie und Mechanik in der Frakturheilung speziell nach Osteosynthese
    • Kuner LD, ed. Stuttgart New York: Thieme
    • Perren S. Biomechanik der Frakturheilung. Übersicht über das Zusammenspiel von Biologie und Mechanik in der Frakturheilung speziell nach Osteosynthese. In: Kuner LD, ed. Kompendium zum AO-Basiskurs. Stabile Osteosynthese Grundlagen-Indikation-Technik. Stuttgart New York: Thieme, 1996.
    • (1996) Kompendium Zum AO-Basiskurs. Stabile Osteosynthese Grundlagen-Indikation-Technik
    • Perren, S.1
  • 14
    • 0028810294 scopus 로고
    • Changes in the AO/ASIF principles and methods
    • Schatzker J. Changes in the AO/ASIF principles and methods. Injury 1995;26(S2):S-B51-S-B56.
    • (1995) Injury , vol.26 , Issue.S2
    • Schatzker, J.1
  • 15
    • 0029269921 scopus 로고
    • "Die biologische Osteosynthese" - Ein unfallchirurgischer Modetrend oder wichtiger operationstechnischer
    • Jg./3
    • Weller S. "Die biologische Osteosynthese" - Ein unfallchirurgischer Modetrend oder wichtiger operationstechnischer Aspekt. Chirurg 1995;34. Jg./3:53-56.
    • (1995) Aspekt. Chirurg , vol.34 , pp. 53-56
    • Weller, S.1
  • 20
    • 0002415874 scopus 로고
    • Morphological findings in primary fracture healing
    • Schenk R, Willenegger H. Morphological findings in primary fracture healing. Symp. Biol. Hung. 1967;7:75-86.
    • (1967) Symp. Biol. Hung. , vol.7 , pp. 75-86
    • Schenk, R.1    Willenegger, H.2
  • 21
    • 0015075976 scopus 로고
    • Primäre und sekundäre Knochenbruchheilung
    • Willenegger H, Perren SM, Schenk R. Primäre und sekundäre Knochenbruchheilung. Chirurg 1971;42: 241-252.
    • (1971) Chirurg , vol.42 , pp. 241-252
    • Willenegger, H.1    Perren, S.M.2    Schenk, R.3
  • 22
    • 0028828643 scopus 로고
    • Radiological sequences of healing in internal plates and splints of different contact surface to bone. (DCP, LC-DCP and PC-Fix)
    • van Frank Haasnoot E, Münch TWH, Matter P, Perren SM. Radiological sequences of healing in internal plates and splints of different contact surface to bone. (DCP, LC-DCP and PC-Fix). Injury 1995; 26(S2):S-B20-S-B23.
    • (1995) Injury , vol.26 , Issue.S2
    • Van Frank Haasnoot, E.1    Münch, T.W.H.2    Matter, P.3    Perren, S.M.4
  • 23
    • 0012096171 scopus 로고    scopus 로고
    • Grundlagen der Plattenosteosynthese - Biologie und Biomechanik
    • Perren S. Grundlagen der Plattenosteosynthese - Biologie und Biomechanik. OP-Journal 1997;13:238-246.
    • (1997) OP-Journal , vol.13 , pp. 238-246
    • Perren, S.1
  • 25
    • 0013203838 scopus 로고    scopus 로고
    • Neue Aspekte und Entwicklungen der Plattenosteosynthese
    • Grützner P, Winkler H, Wentzensen A. Neue Aspekte und Entwicklungen der Plattenosteosynthese. OP-Journal 1997;3:332-338.
    • (1997) OP-Journal , vol.3 , pp. 332-338
    • Grützner, P.1    Winkler, H.2    Wentzensen, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.