메뉴 건너뛰기




Volumn 10, Issue 4, 2001, Pages 624-636

Structural health monitoring by electrical resistance measurement

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CONDUCTIVITY; ELECTRIC INSULATION TESTING; ELECTRIC RESISTANCE MEASUREMENT; INTELLIGENT STRUCTURES; JOINTS (STRUCTURAL COMPONENTS); NONDESTRUCTIVE EXAMINATION; STRUCTURAL LOADS;

EID: 0035417516     PISSN: 09641726     EISSN: None     Source Type: Journal    
DOI: 10.1088/0964-1726/10/4/305     Document Type: Review
Times cited : (116)

References (83)
  • 5
    • 0024089063 scopus 로고
    • Review of magnetic methods for non-destructive evaluation
    • (1988) NDT & E Int. , vol.21 , pp. 311-319
    • Jiles, D.C.1
  • 7
    • 0023542514 scopus 로고
    • Ultrasonic non-destructive evaluation of fibre-reinforced composite materials - A review
    • (1987) Sadhana , vol.11 , pp. 419-432
    • Kinra, V.K.1    Dayal, V.2
  • 25
    • 0031366609 scopus 로고    scopus 로고
    • DC-XA structural health-monitoring fiber optic-based strain measurement system
    • (1997) Proc. SPIE , vol.3044 , pp. 207-218
    • Ellerbrock, P.J.1
  • 31
    • 0029747895 scopus 로고    scopus 로고
    • Rotor acoustic monitoring system (RAMS): A fatigue crack detection system
    • (1996) Proc. SPIE , vol.2717 , pp. 212-218
    • Schoess, J.N.1
  • 39
    • 0029229963 scopus 로고
    • Smart tagged composite using piezoelectric panicles
    • (1995) Proc. SPIE , vol.2442 , pp. 337-348
    • White, S.R.1
  • 42
    • 0000617993 scopus 로고    scopus 로고
    • Sensing delamination in a carbon fiber polymer-matrix composite during fatigue by electrical resistance measurement
    • (1997) Polymer Comp. , vol.18 , pp. 692-700
    • Wang, X.1    Chung, D.D.L.2
  • 45
    • 0033221425 scopus 로고    scopus 로고
    • Fiber breakage in polymer-matrix composite during static and dynamic loading, studied by electrical resistance measurement
    • (1999) J. Mater. Res. , vol.14 , pp. 4224-4229
    • Wang, X.1    Chung, D.D.L.2
  • 46
    • 0033330176 scopus 로고    scopus 로고
    • Interlaminar interface in carbon fiber polymer-matrix composites, studied by contact electrical resistivity measurment
    • (1999) Comp. Interfaces , vol.6 , pp. 497-506
    • Wang, S.1    Chung, D.D.L.2
  • 50
  • 53
    • 0025246934 scopus 로고
    • Damage assessment through electrical resistance measurement in graphite fiber-reinforced composites
    • (1990) Exp. Techniques , vol.14 , pp. 16-20
    • Prabhakaran, R.1
  • 56
    • 0030126886 scopus 로고    scopus 로고
    • Damage mechanisms characterization of carbon fibre/epoxy composite laminates by both electrical resistance measurements and acoustic emission analysis
    • (1996) Scr. Mater. , vol.34 , pp. 1273-1280
    • Ceysson, O.1    Salvia, M.2    Vincent, L.3
  • 64
    • 0030189778 scopus 로고    scopus 로고
    • Carbon fiber reinforced concrete as an intrinsically smart concrete for damage assessment during static and dynamic loading
    • (1996) ACI Mater. J. , vol.93 , pp. 341-350
    • Chen, P.1    Chung, D.D.L.2
  • 65
    • 0029275332 scopus 로고
    • Strain sensors based on the electrical resistance change accompanying the reversible pull-out of conducting short fibers in a less conducting matrix
    • (1995) Smart Mater. Struct. , vol.4 , pp. 59-61
    • Chung, D.D.L.1
  • 68
    • 0033715948 scopus 로고    scopus 로고
    • Effects of temperature and stress on the interface between concrete and its carbon fiber epoxy-matrix composite retrofit, studied by electrical resistance measurement
    • (2000) Cement Concrete Res. , vol.30 , pp. 799-802
    • Mei, Z.1    Chung, D.D.L.2
  • 69
    • 0033024683 scopus 로고    scopus 로고
    • Durability characteristics of concrete columns confined with advanced composite materials
    • (1999) Comp. Struct. , vol.44 , pp. 155-161
    • Toutanji, H.A.1
  • 82
    • 0034301034 scopus 로고    scopus 로고
    • Material contacts under cyclic compression, studied in real time by electrical resistance measurement
    • (2000) J. Mater. Sci. , vol.35 , pp. 4795-4802
    • Luo, X.1    Chung, D.D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.