메뉴 건너뛰기




Volumn 45, Issue 2, 2001, Pages 100-108

The adaptive model of thermal comfort and energy conservation in the built environment

Author keywords

Air conditioning; Energy conservation; Hybrid ventilation; Indoor climate; Natural ventilation; Thermal comfort

Indexed keywords

ACCLIMATIZATION; AIR CONDITIONING; ARTICLE; BIOLOGICAL MODEL; CLIMATE; CONSTRUCTION WORK AND ARCHITECTURAL PHENOMENA; ENERGY CONSERVATION; ENGINEERING; HUMAN; INSTRUMENTATION; STANDARD; UNITED STATES;

EID: 0035407602     PISSN: 00207128     EISSN: None     Source Type: Journal    
DOI: 10.1007/s004840100093     Document Type: Article
Times cited : (415)

References (33)
  • 3
    • 0019727293 scopus 로고
    • Towards a psychophysiological model of thermal perception
    • Auliciems A (1981) Towards a psychophysiological model of thermal perception. Int J Biometeorology 25:109-122
    • (1981) Int J Biometeorology , vol.25 , pp. 109-122
    • Auliciems, A.1
  • 4
    • 0042868390 scopus 로고
    • Psychophysiological criteria for global thermal zones of building design
    • Auliciems A (1983) Psychophysiological criteria for global thermal zones of building design. Int J Biometeorology 27:69-86
    • (1983) Int J Biometeorology , vol.27 , pp. 69-86
    • Auliciems, A.1
  • 5
  • 6
    • 0039275756 scopus 로고
    • Airconditioning in australia. III. Thermobile controls
    • Auliciems A (1990) Airconditioning in Australia. III. Thermobile controls. Architect Sci Rev 33:43-48
    • (1990) Architect Sci Rev , vol.33 , pp. 43-48
    • Auliciems, A.1
  • 8
    • 0033348308 scopus 로고    scopus 로고
    • Field study of occupant thermal comfort and office thermal environments in a hot, arid climate
    • Cena K, de Dear RJ (1999) Field study of occupant thermal comfort and office thermal environments in a hot, arid climate. ASHRAE Trans 105:204-217
    • (1999) ASHRAE Trans , vol.105 , pp. 204-217
    • Cena, K.1    De Dear, R.J.2
  • 10
    • 0042367354 scopus 로고
    • Outdoor climatic influences on indoor thermal comfort requirements
    • Oseland NA, Humphreys MA (eds) BRE, Garston
    • de Dear RJ (1994) Outdoor climatic influences on indoor thermal comfort requirements. In: Oseland NA, Humphreys MA (eds) Thermal comfort: past present and future. BRE, Garston
    • (1994) Thermal Comfort: Past Present and Future
    • De Dear, R.J.1
  • 11
    • 0031632764 scopus 로고    scopus 로고
    • A global database of thermal comfort field experiments
    • de Dear RJ (1998a) A global database of thermal comfort field experiments. ASHRAE Trans 104:1141-1152
    • (1998) ASHRAE Trans , vol.104 , pp. 1141-1152
    • De Dear, R.J.1
  • 12
    • 0042367353 scopus 로고    scopus 로고
    • A global database of thermal comfort applied to questions of air speed and humidity limits in standards
    • ICHES98 Organising Committee (eds) Yokohama November 1998. The Organizing Committee for International Conference on Human-Environment System. Yokohama
    • de Dear RJ (1998b) A global database of thermal comfort applied to questions of air speed and humidity limits in standards. In: ICHES98 Organising Committee (eds) Proceedings of the Second International Conference on Human-Environment System, Yokohama November 1998. The Organizing Committee for International Conference on Human-Environment System. Yokohama, pp 342-345
    • (1998) Proceedings of the Second International Conference on Human-Environment System , pp. 342-345
    • De Dear, R.J.1
  • 13
    • 0031624196 scopus 로고    scopus 로고
    • Developing an adaptive model of thermal comfort and preference
    • de Dear RJ, Brager GS (1998) Developing an adaptive model of thermal comfort and preference. ASHRAE Trans 104:145-167
    • (1998) ASHRAE Trans , vol.104 , pp. 145-167
    • De Dear, R.J.1    Brager, G.S.2
  • 14
    • 0001046585 scopus 로고    scopus 로고
    • Field study on the impact of temperature, humidity and ventilation on perceived air quality
    • Raw G, Aizlewood C, Warren P (eds) Indoor Air 99 Organising Committee, Edinburgh
    • Fang L, Wargocki P, Witterseh T, Clausen G, Fanger PO (1999) Field study on the impact of temperature, humidity and ventilation on perceived air quality. In: Raw G, Aizlewood C, Warren P (eds) Proceedings of Indoor Air'99, Edinburgh, Scotland, Vol 2, Indoor Air 99 Organising Committee, Edinburgh, pp 107-112
    • (1999) Proceedings of Indoor Air'99, Edinburgh, Scotland , vol.2 , pp. 107-112
    • Fang, L.1    Wargocki, P.2    Witterseh, T.3    Clausen, G.4    Fanger, P.O.5
  • 16
    • 0041866315 scopus 로고    scopus 로고
    • A moderate enthalpy and a low pollution load in healthy buildings
    • ICHES98 Organising Committee (eds) Yokohama November 1998
    • Fanger PO (1998) A moderate enthalpy and a low pollution load in healthy buildings. In: ICHES98 Organising Committee (eds) Proceedings of the Second International Conference on Human-Environment System. Yokohama November 1998, pp 608-613
    • (1998) Proceedings of the Second International Conference on Human-Environment System , pp. 608-613
    • Fanger, P.O.1
  • 17
    • 0042367355 scopus 로고    scopus 로고
    • Wincomf: A windows 3.1 thermal sensation model
    • Environmental Analytics, Berkeley
    • Fountain ME, Huizenga C (1996) WinComf: A Windows 3.1 thermal sensation model. User's manual. Environmental Analytics, Berkeley
    • (1996) User's Manual
    • Fountain, M.E.1    Huizenga, C.2
  • 19
    • 0034461893 scopus 로고    scopus 로고
    • Effects of measurement and formulation error on thermal comfort indices in the ASHRAE database of field studies
    • Humphreys M, Nicol F (2000) Effects of measurement and formulation error on thermal comfort indices in the ASHRAE database of field studies. ASHRAE Trans 106:493-502
    • (2000) ASHRAE Trans , vol.106 , pp. 493-502
    • Humphreys, M.1    Nicol, F.2
  • 23
    • 4243545317 scopus 로고
    • Ventilation of office buildings: Deciding the appropriate system
    • Leaman AJ, Cohen RR, Jackman PJ (1995) Ventilation of office buildings: deciding the appropriate system. Heat Air Condit J 68:90-101
    • (1995) Heat Air Condit J , vol.68 , pp. 90-101
    • Leaman, A.J.1    Cohen, R.R.2    Jackman, P.J.3
  • 24
    • 0000038524 scopus 로고
    • Non-specific symptoms in ottice workers: A review of the epidemiologic literature
    • Mendell MJ (1993) Non-specific symptoms in ottice workers: a review of the epidemiologic literature. Indoor Air 3:227-236
    • (1993) Indoor Air , vol.3 , pp. 227-236
    • Mendell, M.J.1
  • 25
    • 0041365538 scopus 로고    scopus 로고
    • Elevated symptom prevalence associated with ventilation type in office buildings
    • Mendell MJ, Fisk WJ, Deddens JA (1997) Elevated symptom prevalence associated with ventilation type in office buildings. Occup Health Ind Med 36:9
    • (1997) Occup Health Ind Med , vol.36 , pp. 9
    • Mendell, M.J.1    Fisk, W.J.2    Deddens, J.A.3
  • 27
    • 0041365539 scopus 로고
    • Thermal comfort standards: Past, present and future, and open discussion that follows
    • Oseland NA, Humphreys MA (eds) BRE, Garston
    • Parsons K (1994) Thermal comfort standards: past, present and future, and open discussion that follows. In: Oseland NA, Humphreys MA (eds) Thermal comfort: past, present and future. BRE, Garston, pp 184-197
    • (1994) Thermal Comfort: Past, Present and Future , pp. 184-197
    • Parsons, K.1
  • 28
    • 0027047007 scopus 로고
    • On condis and coolth
    • Prins G (1992) On condis and coolth. Energy and buildings 18: 251-258
    • (1992) Energy and Buildings , vol.18 , pp. 251-258
    • Prins, G.1
  • 30
    • 0003911715 scopus 로고
    • Wissenschaftliche Verlagsgesellschaft, Stuttgart
    • Rudloff W (1981) World climates. Wissenschaftliche Verlagsgesellschaft, Stuttgart
    • (1981) World Climates
    • Rudloff, W.1
  • 31
  • 32
    • 59349105232 scopus 로고    scopus 로고
    • Bioclimatic architecture and solar energy
    • Auliciems A (ed) Springer, Berlin Heidelberg New York
    • Szokolay SV (1998) Bioclimatic architecture and solar energy. In: Auliciems A (ed) Advances in bioclimatology. Springer, Berlin Heidelberg New York, pp 111-131
    • (1998) Advances in Bioclimatology , pp. 111-131
    • Szokolay, S.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.