메뉴 건너뛰기




Volumn 32, Issue 7, 2001, Pages 517-520

Viability of magnetic denture retainers: A 3-year case report

Author keywords

Magnets; Neodymium iron boron; Overdentures; Rare earth magnet; Removable partial dentures; Retention

Indexed keywords

LANTHANIDE;

EID: 0035407431     PISSN: 00336572     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 10844282739 scopus 로고
    • The use of magnetic force in prosthetic dentistry
    • Grimaldi RM. The use of magnetic force in prosthetic dentistry. Dent Dig 1954;60:205-207.
    • (1954) Dent Dig , vol.60 , pp. 205-207
    • Grimaldi, R.M.1
  • 2
    • 0039779695 scopus 로고
    • The implantation of magnets in the jaws to aid denture retention
    • Behrman SJ. The implantation of magnets in the jaws to aid denture retention. J Prosthet Dent 1960;10:807-814.
    • (1960) J Prosthet Dent , vol.10 , pp. 807-814
    • Behrman, S.J.1
  • 3
    • 10844278264 scopus 로고
    • Intraradicular anchorage of overlay dentures using cobalt rare earth magnets
    • Gillings BRD. Intraradicular anchorage of overlay dentures using cobalt rare earth magnets. Aust Soc Prosth Bull 1977; 7:27-32.
    • (1977) Aust Soc Prosth Bull , vol.7 , pp. 27-32
    • Gillings, B.R.D.1
  • 4
    • 0019571593 scopus 로고
    • Magnetic retention for complete and partial overdentures. Part 1
    • Gillings BRD. Magnetic retention for complete and partial overdentures. Part 1. J Prosthet Dent 1981;45:484-491.
    • (1981) J Prosthet Dent , vol.45 , pp. 484-491
    • Gillings, B.R.D.1
  • 5
    • 0020760944 scopus 로고
    • Magnetic retention for overdentures. Part 2
    • Gillings BRD. Magnetic retention for overdentures. Part 2. J Prosthet Dent 1983;49:607-618.
    • (1983) J Prosthet Dent , vol.49 , pp. 607-618
    • Gillings, B.R.D.1
  • 6
    • 0026176177 scopus 로고
    • Corrosion under static and dynamic conditions of alloys used for magnetic retention in dentistry
    • Angelini E, Pezzoli M, Zucchi F. Corrosion under static and dynamic conditions of alloys used for magnetic retention in dentistry. J Prosthet Dent 1991;65:848-853.
    • (1991) J Prosthet Dent , vol.65 , pp. 848-853
    • Angelini, E.1    Pezzoli, M.2    Zucchi, F.3
  • 7
    • 0027909478 scopus 로고
    • Magnet retained overdentures using the Astra dental implant system
    • Walmsley AD, Brady CL, Smith PL, Frame JW. Magnet retained overdentures using the Astra dental implant system. Br Dent J 1993;174:399-404.
    • (1993) Br Dent J , vol.174 , pp. 399-404
    • Walmsley, A.D.1    Brady, C.L.2    Smith, P.L.3    Frame, J.W.4
  • 9
    • 0039187279 scopus 로고    scopus 로고
    • Implant supported overdentures - The Birmingham experience
    • Walmsley AD, Frame JW. Implant supported overdentures - The Birmingham experience. J Dent 1997;25(suppl 1):43-47.
    • (1997) J Dent , vol.25 , Issue.1 SUPPL. , pp. 43-47
    • Walmsley, A.D.1    Frame, J.W.2
  • 10
    • 0023175529 scopus 로고
    • Rare earth magnetic attachments: The state of the art in removable prosthodontics
    • Jackson TR, Healey KW. Rare earth magnetic attachments: The state of the art in removable prosthodontics. Quintessence Int 1987;18:41-51.
    • (1987) Quintessence Int , vol.18 , pp. 41-51
    • Jackson, T.R.1    Healey, K.W.2
  • 13
    • 0033249821 scopus 로고    scopus 로고
    • The durability of parylene coatings on neodymium-iron-boron magnets
    • Noar JH, Wahab A, Evans RD, Wojcik AG. The durability of parylene coatings on neodymium-iron-boron magnets. Eur J Orthod 1999;21:685-693.
    • (1999) Eur J Orthod , vol.21 , pp. 685-693
    • Noar, J.H.1    Wahab, A.2    Evans, R.D.3    Wojcik, A.G.4
  • 14
    • 0025986264 scopus 로고
    • The direct and indirect techniques of making magnetically retained overdentures
    • Wang NH, von der Lehr WN. The direct and indirect techniques of making magnetically retained overdentures. J Prosthet Dent 1991;65:112-117.
    • (1991) J Prosthet Dent , vol.65 , pp. 112-117
    • Wang, N.H.1    Von Der Lehr, W.N.2
  • 15
    • 0033122044 scopus 로고    scopus 로고
    • Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets: 5-year results
    • Davis DM, Packer ME. Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets: 5-year results. Int J Prosthodont 1999;12:222-229.
    • (1999) Int J Prosthodont , vol.12 , pp. 222-229
    • Davis, D.M.1    Packer, M.E.2
  • 16
    • 0028541409 scopus 로고
    • Orthodontic rare earth magnets - In vitro assessment of cytotoxicity
    • Bondemark L, Kurol J, Wennberg A. Orthodontic rare earth magnets - In vitro assessment of cytotoxicity. Br J Orthod 1994;21:335-341.
    • (1994) Br J Orthod , vol.21 , pp. 335-341
    • Bondemark, L.1    Kurol, J.2    Wennberg, A.3
  • 17
    • 0031033350 scopus 로고    scopus 로고
    • Corrosion of intra-oral magnets by multi-species biofilms in the presence and absence of sucrose
    • Wilson M, Patel H, Kpendema H, Noar JH, Hunt NP, Mordan NJ. Corrosion of intra-oral magnets by multi-species biofilms in the presence and absence of sucrose. Biomaterials 1997;18:53-57.
    • (1997) Biomaterials , vol.18 , pp. 53-57
    • Wilson, M.1    Patel, H.2    Kpendema, H.3    Noar, J.H.4    Hunt, N.P.5    Mordan, N.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.