Volumn 33, Issue 5, 2001, Pages 503-507

Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ

Author keywords

[No Author keywords available]

Indexed keywords

BOREHOLES; HEAT EXCHANGERS; HEAT RESISTANCE; THERMAL CONDUCTIVITY OF SOLIDS;

EID: 0035342497     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0378-7788(00)00106-7     Document Type: Article
Times cited : (163)

References (11)
  • 1
    • 85031532281 scopus 로고
    • Die grösste erdgekoppelte Wärmepumpenanlage der Welt-Richard Stockton College New Jersey
    • c/o GTN Postfach 1824 17008 Neubrandenburg Deutschland
    • B. Sanner, L. Stiles, Die grösste erdgekoppelte Wärmepumpenanlage der Welt-Richard Stockton College New Jersey, Geothermische Energie Mitteilungsblatt der Geothermisches Vereinigung/GtV Nr. 12 c/o GTN Postfach 1824 17008 Neubrandenburg Deutschland, 1995.
    • (1995) Geothermische Energie Mitteilungsblatt der Geothermisches Vereinigung/GtV Nr. 12
    • Sanner, B.1    Stiles, L.2
  • 4
    • 0003887997 scopus 로고
    • Thesis, Department of Mathematical Physics, Lund Institute of Technology, Lund, Sweden
    • P. Eskilson, Thermal Analysis of Heat Extraction Boreholes, Thesis, Department of Mathematical Physics, Lund Institute of Technology, Lund, Sweden, 1987.
    • (1987) Thermal Analysis of Heat Extraction Boreholes
    • Eskilson, P.1
  • 9
    • 0343453754 scopus 로고    scopus 로고
    • Heat exchanger pile system for heating and cooling at Zürich airport
    • Pahud D., Fromentin A., Hubbuch M. Heat exchanger pile system for heating and cooling at Zürich airport. IEA Heat Pump Centre Newslett. 17(1):1999;15-16.
    • (1999) IEA Heat Pump Centre Newslett. , vol.17 , Issue.1 , pp. 15-16
    • Pahud, D.1    Fromentin, A.2    Hubbuch, M.3
  • 10
    • 84878636298 scopus 로고    scopus 로고
    • Heat Exchanger Pile System of the Dock Midfield at the Zürich Airport
    • Final report, Swiss Federal Office of Energy, Switzerland
    • D. Pahud, A. Fromentin, M. Hubbuch, Heat Exchanger Pile System of the Dock Midfield at the Zürich Airport, Detailed Simulation and Optimisation of the Installation, Final report, Swiss Federal Office of Energy, Switzerland, 1999.
    • (1999) Detailed Simulation and Optimisation of the Installation
    • Pahud, D.1    Fromentin, A.2    Hubbuch, M.3
  • 11
    • 0142180664 scopus 로고
    • Software for dimensioning of deep boreholes for heat extraction
    • Espoo, Finland
    • G. Hellström, B. Sanner, Software for dimensioning of deep boreholes for heat extraction, in: Proceedings of the Calorstock'94, Espoo, Finland, 1994, pp. 195-200.
    • (1994) In: Proceedings of the Calorstock'94 , pp. 195-200
    • Hellström, G.1    Sanner, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.