메뉴 건너뛰기




Volumn 42, Issue 3, 2001, Pages 291-293

A comparative study of MR imaging profile of titanium pedicle screws

Author keywords

MR imaging; Spine, implants; Titanium

Indexed keywords

TITANIUM;

EID: 0035324588     PISSN: 02841851     EISSN: None     Source Type: Journal    
DOI: 10.1080/028418501127346846     Document Type: Article
Times cited : (25)

References (14)
  • 1
    • 0023706020 scopus 로고
    • Heating effects of metallic implants by MRI examinations
    • BUCHLI R., BOESIGER P. & MEIER D.: Heating effects of metallic implants by MRI examinations. Magn. Reson. Med. 7 (1988), 255.
    • (1988) Magn. Reson. Med. , vol.7 , pp. 255
    • Buchli, R.1    Boesiger, P.2    Meier, D.3
  • 4
    • 0029979618 scopus 로고    scopus 로고
    • Postoperative magnetic resonance imaging with titanium implants of the thoracic and lumbar spine
    • ORTIZ Q., PAIT G., MCALLISTER P. & SAUTER K.: Postoperative magnetic resonance imaging with titanium implants of the thoracic and lumbar spine. Neurosurgery 38 (1996), 741.
    • (1996) Neurosurgery , vol.38 , pp. 741
    • Ortiz, Q.1    Pait, G.2    McAllister, P.3    Sauter, K.4
  • 5
    • 0030012255 scopus 로고    scopus 로고
    • Optimizing imaging parameters for MR evaluation of the spine with titanium pedicle screws
    • PETERSILGE C. A., LEWIN J. S., DUREK J. L., YOO J. U. & GHANEYEM A. J.: Optimizing imaging parameters for MR evaluation of the spine with titanium pedicle screws. AJR 166 (1996), 1213.
    • (1996) AJR , vol.166 , pp. 1213
    • Petersilge, C.A.1    Lewin, J.S.2    Durek, J.L.3    Yoo, J.U.4    Ghaneyem, A.J.5
  • 6
    • 0027411830 scopus 로고
    • Magnetic resonance imaging evaluation of the spine with metal implants. General safety and superior imaging with titanium
    • RUPP R., EBRAHEIM N. A., SAVOLAINE E. R. & JACKSON W. T.: Magnetic resonance imaging evaluation of the spine with metal implants. General safety and superior imaging with titanium. Spine 18 (1993), 379.
    • (1993) Spine , vol.18 , pp. 379
    • Rupp, R.1    Ebraheim, N.A.2    Savolaine, E.R.3    Jackson, W.T.4
  • 7
    • 0029736711 scopus 로고    scopus 로고
    • The value of magnetic resonance imaging of the postoperative spine with titanium implants
    • RUPP R., EBRAHEIM N. & WONG F.: The value of magnetic resonance imaging of the postoperative spine with titanium implants. J. Spine Disord. 9 (1996), 342.
    • (1996) J. Spine Disord. , vol.9 , pp. 342
    • Rupp, R.1    Ebraheim, N.2    Wong, F.3
  • 8
    • 0023765495 scopus 로고
    • MR imaging of metallic implants and materials. A compilation of the literature
    • SCHELLOCK F. G.: MR imaging of metallic implants and materials. A compilation of the literature. AJR 151 (1988), 811.
    • (1988) AJR , vol.151 , pp. 811
    • Schellock, F.G.1
  • 9
    • 0028097780 scopus 로고
    • Metallic artifacts on MR images of the postoperative spine. Reduction with fast spin-echo techniques
    • TARTAGLINO L. M., FLANDERS A. E., VINITSKI S. & FRIEDMAN D. P.: Metallic artifacts on MR images of the postoperative spine. Reduction with fast spin-echo techniques. Radiology 190 (1994), 565.
    • (1994) Radiology , vol.190 , pp. 565
    • Tartaglino, L.M.1    Flanders, A.E.2    Vinitski, S.3    Friedman, D.P.4
  • 10
    • 0346397053 scopus 로고
    • MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents and coils
    • TEITELBAUM G. P., BRADLEY W. G. JR & KLEIN B. D.: MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents and coils. Radiology 147 (1988), 139.
    • (1988) Radiology , vol.147 , pp. 139
    • Teitelbaum, G.P.1    Bradley W.G., Jr.2    Klein, B.D.3
  • 11
    • 0028900149 scopus 로고
    • Magnetic resonance imaging of titanium anterior cervical plating systems
    • TOMINNAGA T., SHIMIZU H., KOSHU K., KAYAMA T. & YOSHIMOTO T.: Magnetic resonance imaging of titanium anterior cervical plating systems. Neurosurgery 36 (1995), 951.
    • (1995) Neurosurgery , vol.36 , pp. 951
    • Tominnaga, T.1    Shimizu, H.2    Koshu, K.3    Kayama, T.4    Yoshimoto, T.5
  • 12
    • 0028881644 scopus 로고
    • The use of MRI-compatible titanium segmental spinal instrumentation in pediatric patients with intraspinal tumors
    • TORPEY B., DORMANS J. P. & DRUMMOND D. S.: The use of MRI-compatible titanium segmental spinal instrumentation in pediatric patients with intraspinal tumors. J. Spinal Disord. 1 (1995), 76.
    • (1995) J. Spinal Disord. , vol.1 , pp. 76
    • Torpey, B.1    Dormans, J.P.2    Drummond, D.S.3
  • 14
    • 0032143448 scopus 로고
    • A comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium spinal instrumentation
    • WANG J. C., YU W. D., HARVINDER S. S., TAM V. & DELAMARTER R. B.: A comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium spinal instrumentation. Spine 23 (1988), 1684.
    • (1988) Spine , vol.23 , pp. 1684
    • Wang, J.C.1    Yu, W.D.2    Harvinder, S.S.3    Tam, V.4    Delamarter, R.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.