메뉴 건너뛰기




Volumn 16, Issue 2, 2001, Pages 265-271

Validation for tremor quantification of an electromagnetic tracking device

Author keywords

Electromagnetic tracking device; Essential tremor; Parkinson's disease; Tremor quantification

Indexed keywords

ACCELERATION; ALGORITHM; ARM MOVEMENT; ARTICLE; CALCULATION; CONTROLLED STUDY; CORRELATION FUNCTION; DIAGNOSTIC ACCURACY; HUMAN; MAGNETIC AND ELECTROMAGNETIC EQUIPMENT; NEUROLOGIC DISEASE; OSCILLATION; PARKINSON DISEASE; PHYSICIAN; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REPRODUCIBILITY; TREMOR; VALIDATION PROCESS;

EID: 0035297097     PISSN: 08853185     EISSN: None     Source Type: Journal    
DOI: 10.1002/mds.1064     Document Type: Article
Times cited : (51)

References (14)
  • 1
    • 0000483330 scopus 로고
    • Clinical rating scale for tremor
    • Jankovic J, Tolosa E, eds. Baltimore-Munich: Urban & Schwarzenberg
    • Fahn S, Tolosa E, Marin C. Clinical rating scale for tremor. In: Jankovic J, Tolosa E, eds. Parkinson's disease and movement disorders. Baltimore-Munich: Urban & Schwarzenberg; 1988:225-234.
    • (1988) Parkinson's Disease and Movement Disorders , pp. 225-234
    • Fahn, S.1    Tolosa, E.2    Marin, C.3
  • 4
    • 0030690235 scopus 로고    scopus 로고
    • Validity of long-term electromyography in the quantification of tremor
    • Spieker S, Strole V, Sailer A, Boose A, Dichgans J. Validity of long-term electromyography in the quantification of tremor. Mov Disord 1997;12:985-991.
    • (1997) Mov. Disord. , vol.12 , pp. 985-991
    • Spieker, S.1    Strole, V.2    Sailer, A.3    Boose, A.4    Dichgans, J.5
  • 5
    • 0019470879 scopus 로고
    • Quantitative assessment of parkinsonian and essential tremor: Clinical application of triaxial accelerometry
    • Jankovic J, Frost JD, Jr. Quantitative assessment of parkinsonian and essential tremor: clinical application of triaxial accelerometry. Neurology 1981;31:1235-1240.
    • (1981) Neurology , vol.31 , pp. 1235-1240
    • Jankovic, J.1    Frost, J.D.2
  • 8
    • 0025287654 scopus 로고
    • Quantification of tremor with a digitizing tablet
    • Elble RJ, Sinha R, Higgins C. Quantification of tremor with a digitizing tablet. J Neurosci Methods 1990;32:193-198.
    • (1990) J. Neurosci. Methods , vol.32 , pp. 193-198
    • Elble, R.J.1    Sinha, R.2    Higgins, C.3
  • 10
    • 0031739349 scopus 로고    scopus 로고
    • Spiral analysis: A new technique for measuring tremor with a digitizing tablet
    • Pullman SL. Spiral analysis: a new technique for measuring tremor with a digitizing tablet. Mov Disord 1998;13 Suppl 3:85-89.
    • (1998) Mov. Disord. , vol.13 , pp. 85-89
    • Pullman, S.L.1
  • 11
    • 0033957963 scopus 로고    scopus 로고
    • Validation of a portable instrument for assessing tremor severity in epidemiologic field studies
    • Louis ED, Yousefzadeh E, Barnes LF, Yu Q, Pullman SL, Wendt KJ. Validation of a portable instrument for assessing tremor severity in epidemiologic field studies. Mov Disord 2000;15:95-102.
    • (2000) Mov. Disord. , vol.15 , pp. 95-102
    • Louis, E.D.1    Yousefzadeh, E.2    Barnes, L.F.3    Yu, Q.4    Pullman, S.L.5    Wendt, K.J.6
  • 13
    • 0032843154 scopus 로고    scopus 로고
    • Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking system
    • Barrett CJ, Singer KP, Day R. Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking system. Manual Therapy 1999;4:94-99.
    • (1999) Manual Therapy , vol.4 , pp. 94-99
    • Barrett, C.J.1    Singer, K.P.2    Day, R.3
  • 14
    • 0033500814 scopus 로고    scopus 로고
    • Classification of normal and pathological tremors using a multidimensional electromagnetic system
    • Spyers-Ashby JM, Stokes MJ, Bain PG, Roberts SJ. Classification of normal and pathological tremors using a multidimensional electromagnetic system. Med Engineering Physics 1999;21:713-723.
    • (1999) Med. Engineering Physics , vol.21 , pp. 713-723
    • Spyers-Ashby, J.M.1    Stokes, M.J.2    Bain, P.G.3    Roberts, S.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.