Volumn 20, Issue 3, 2001, Pages 218-232
|
An EM algorithm for estimating SPECT emission and transmission parameters from emission data only
|
Author keywords
Attenuation maps; EM; Multiple sources; SPECT
|
Indexed keywords
COMPUTER SIMULATION;
MAXIMUM LIKELIHOOD ESTIMATION;
PARAMETER ESTIMATION;
PHOTONS;
PHOTON EMISSION;
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT);
COMPUTERIZED TOMOGRAPHY;
ALGORITHM;
ARTICLE;
HUMAN;
IMAGE PROCESSING;
IMAGE QUALITY;
METHODOLOGY;
SCINTISCANNING;
SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;
THORAX;
ALGORITHMS;
HUMANS;
IMAGE PROCESSING, COMPUTER-ASSISTED;
PHANTOMS, IMAGING;
THORAX;
TOMOGRAPHY, EMISSION-COMPUTED, SINGLE-PHOTON;
|
EID: 0035263306
PISSN: 02780062
EISSN: None
Source Type: Journal
DOI: 10.1109/42.918472 Document Type: Article |
Times cited : (76)
|
References (65)
|