-
2
-
-
0012749581
-
Fluoroscopes and fluoroscopy
-
W.E. Chamberlain, "Fluoroscopes and fluoroscopy," Radiology 38, 383-412, 1942.
-
(1942)
Radiology
, vol.38
, pp. 383-412
-
-
Chamberlain, W.E.1
-
4
-
-
0014535679
-
Display format and decision making in television processing of chest radiographs
-
H.L. Kundel, G. Revesz, F.J. Shea, "Display format and decision making in television processing of chest radiographs," Invest. Radiol. 4, 264-7, 1969.
-
(1969)
Invest. Radiol.
, vol.4
, pp. 264-267
-
-
Kundel, H.L.1
Revesz, G.2
Shea, F.J.3
-
5
-
-
70449276020
-
Studies on the accuracy of diagnostic procedures
-
L.H. Garland, "Studies on the accuracy of diagnostic procedures," Am. J. Roent. 82, 25-38, 1959.
-
(1959)
Am. J. Roent.
, vol.82
, pp. 25-38
-
-
Garland, L.H.1
-
6
-
-
0014649064
-
Roentgen image perception - A personal survey of the problem
-
W.J. Tuddenham, "Roentgen image perception-A personal survey of the problem," Radiologic Clinics of North America, VII, 499-501, 1969.
-
(1969)
Radiologic Clinics of North America
, vol.7
, pp. 499-501
-
-
Tuddenham, W.J.1
-
7
-
-
0012649621
-
The visual physiology of roentgen diagnosis
-
W.J. Tuddenham, "The visual physiology of roentgen diagnosis," Am. J. Roent. 78, 116-23, 1957.
-
(1957)
Am. J. Roent.
, vol.78
, pp. 116-123
-
-
Tuddenham, W.J.1
-
8
-
-
0012710756
-
The perceptibility of details in roentgen examinations of the lung
-
G.C.E. Burger, "The perceptibility of details in roentgen examinations of the lung," Acta Radiol. Diagn. 31, 193-222, 1949.
-
(1949)
Acta Radiol. Diagn
, vol.31
, pp. 193-222
-
-
Burger, G.C.E.1
-
9
-
-
0001191221
-
On the scientific evaluation of diagnostic procedures
-
L.H. Garland, "On the scientific evaluation of diagnostic procedures," Radiology 52, 309-28, 1949.
-
(1949)
Radiology
, vol.52
, pp. 309-328
-
-
Garland, L.H.1
-
11
-
-
84894009825
-
-
note
-
The concept of a variable sensory magnitude in the observer to a given stimulus was pioneered by Loius Leon Thurstone.
-
-
-
-
12
-
-
0003588227
-
Signal detection theory and ROC analysis in psychology and diagnostics
-
Lawrence Erlbaum Assoc.
-
J.A. Swets, Signal Detection Theory and ROC Analysis in PsychoLogy and Diagnostics, Sci. Psych. Series (Lawrence Erlbaum Assoc. 1996).
-
(1996)
Sci. Psych. Series
-
-
Swets, J.A.1
-
13
-
-
84937349279
-
The theory of signal detectability
-
W.W. Peterson, T.G. Birdsall, W.C. Fox, "The theory of signal detectability," Transactions of the IRE PGIT, 4, 171-212, 1954.
-
(1954)
Transactions of the IRE PGIT
, vol.4
, pp. 171-212
-
-
Peterson, W.W.1
Birdsall, T.G.2
Fox, W.C.3
-
14
-
-
0000920209
-
A decision making theory of visual detection
-
W.P. Tanner, Jr., J.A. Swets," A decision making theory of visual detection," Tanner and Swets, Psychol. Rev. 61, 401, 1954.
-
(1954)
Tanner and Swets, Psychol. Rev.
, vol.61
, pp. 401
-
-
Tanner W.P., Jr.1
Swets, J.A.2
-
16
-
-
0014265939
-
Maximum likelihood estimation of parameters of signal detection theory - A direct solution
-
D.D. Dorfman and E.Alf, Jr., "Maximum likelihood estimation of parameters of signal detection theory - a direct solution," Psychometrika 33, 127-34, 1968.
-
(1968)
Psychometrika
, vol.33
, pp. 127-134
-
-
Dorfman, D.D.1
Alf E., Jr.2
-
17
-
-
0032525017
-
Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously distributed data
-
C.E. Metz, B.A. Herman, J.H. Shen, "Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously distributed data," Stat. Med. 15, 1033-53, 1998.
-
(1998)
Stat. Med.
, vol.15
, pp. 1033-1053
-
-
Metz, C.E.1
Herman, B.A.2
Shen, J.H.3
-
18
-
-
0025269074
-
Free-response methodology: Alternate analysis and a new observer performance experiment
-
D.P. Chakraborty, L.H. Winter, "Free-response methodology: alternate analysis and a new observer performance experiment," Radiology 174, 873-81, 1990.
-
(1990)
Radiology
, vol.174
, pp. 873-881
-
-
Chakraborty, D.P.1
Winter, L.H.2
-
19
-
-
84957519673
-
The sensitivity performance of the human eye on an absolute scale
-
A. Rose, "The sensitivity performance of the human eye on an absolute scale," J. Opt. Soc. Am.A 38, 196-208, 1948.
-
(1948)
J. Opt. Soc. Am.A
, vol.38
, pp. 196-208
-
-
Rose, A.1
-
20
-
-
0033088416
-
The Rose model, revisited
-
For information on how the Rose model relates to more contemporary models see:A.E. Burgess "The Rose model, revisited," J. of the Opt. Soc. of Am.A 16, 633-46, 1999.
-
(1999)
J. of the Opt. Soc. of Am.A
, vol.16
, pp. 633-646
-
-
Burgess, A.E.1
-
21
-
-
0013889038
-
Visual perception in fluoroscopy and radiography
-
R.H. Morgan,"Visual perception in fluoroscopy and radiography," Radiology 86, 403-16, 1966.
-
(1966)
Radiology
, vol.86
, pp. 403-416
-
-
Morgan, R.H.1
-
22
-
-
0000163436
-
Screen intensification systems and their limitations
-
R.E. Strum and R.H. Morgan, "Screen intensification systems and their limitations," Am. J. of Roentgenol. 62, 617-34, 1949.
-
(1949)
Am. J. of Roentgenol.
, vol.62
, pp. 617-634
-
-
Strum, R.E.1
Morgan, R.H.2
-
23
-
-
0014816549
-
The central problem in the study of radiographic image quality
-
K. Rossmann and B.E. Wiley, "The central problem in the study of radiographic image quality," Radiology 96, 113-8, 1970.
-
(1970)
Radiology
, vol.96
, pp. 113-118
-
-
Rossmann, K.1
Wiley, B.E.2
-
24
-
-
0014238946
-
The spatial frequency spectrum: A means for studying the quality of radiographic imaging systems
-
K. Rossmann, "The spatial frequency spectrum: a means for studying the quality of radiographic imaging systems," Radiology 90, 1-13, 1968.
-
(1968)
Radiology
, vol.90
, pp. 1-13
-
-
Rossmann, K.1
-
25
-
-
0016320021
-
An approach to image quality evaluation using observer performance studies
-
K. Rossmann, "An approach to image quality evaluation using observer performance studies," Radiology 113, 541-4, 1974.
-
(1974)
Radiology
, vol.113
, pp. 541-544
-
-
Rossmann, K.1
-
26
-
-
0002997954
-
Electro-optical characteristics of television systems
-
O.H. Schade, "Electro-optical characteristics of television systems" RCA Rev. 9, 5-37, 1948.
-
(1948)
RCA Rev.
, vol.9
, pp. 5-37
-
-
Schade, O.H.1
-
27
-
-
84938168609
-
Analysis of the factors which determine signal-noise discrimination in pulsed carrier systems
-
PTR6C, reprinted in Proc. IRES1
-
D.O. North, "Analysis of the factors which determine signal-noise discrimination in pulsed carrier systems," RCA Tech. Rep. PTR6C, reprinted in Proc. IRES1, 1016-28, 1943.
-
(1943)
RCA Tech. Rep.
, pp. 1016-1028
-
-
North, D.O.1
-
28
-
-
84957509337
-
An assortment of image quality indexes for radiographic film screen combinations - Can they be resolved?
-
R.F. Wagner and K. Weaver, "An assortment of image quality indexes for radiographic film screen combinations-Can they be resolved?," Proc. SPIE, Application of Optical Instrumentation in Medicine 35, 83-94, 1972.
-
(1972)
Proc. SPIE, Application of Optical Instrumentation in Medicine
, vol.35
, pp. 83-94
-
-
Wagner, R.F.1
Weaver, K.2
-
29
-
-
0017639915
-
Toward a unified view of radiological imaging systems. Part II: Noisy images
-
R.F. Wagner, "Toward a unified view of radiological imaging systems. Part II: Noisy Images," Medical Physics 4, 279-300, 1977.
-
(1977)
Medical Physics
, vol.4
, pp. 279-300
-
-
Wagner, R.F.1
-
30
-
-
0001098005
-
Retinal noise and absolute threshold
-
H.B. Barlow, "Retinal noise and absolute threshold," J. Opt. Soc. Am.A 46, 634-9, 1956.
-
(1956)
J. Opt. Soc. Am.A
, vol.46
, pp. 634-639
-
-
Barlow, H.B.1
-
31
-
-
0018194382
-
The efficiency of detecting changes of density in random dot patterns
-
H.B. Barlow, "The efficiency of detecting changes of density in random dot patterns," Vis. Res. 18, 637-50, 1978.
-
(1978)
Vis. Res.
, vol.18
, pp. 637-650
-
-
Barlow, H.B.1
-
32
-
-
0019870643
-
Efficiency of human visual signal discrimination
-
A.E. Burgess, R.F. Wagner, R.J. Jennings, and H.B. Barlow, "Efficiency of human visual signal discrimination," Science 214, 93-4, 1981.
-
(1981)
Science
, vol.214
, pp. 93-94
-
-
Burgess, A.E.1
Wagner, R.F.2
Jennings, R.J.3
Barlow, H.B.4
-
33
-
-
0021475537
-
Visual signal detection II. Signal-location identification
-
A.E. Burgess, H. Ghandeharian, "Visual signal detection II. Signal-location identification," J. Opt. Soc. Am.A 1, 906-10, 1984.
-
(1984)
J. Opt. Soc. Am.A
, vol.1
, pp. 906-910
-
-
Burgess, A.E.1
Ghandeharian, H.2
-
34
-
-
0019578259
-
Detection of noisy visual targets: Model for the effects of spatial uncertainty and signal to noise ratio
-
R.G. Swesson, P.F.Judy, "Detection of noisy visual targets: model for the effects of spatial uncertainty and signal to noise ratio," Perception and Psychophysics 29, 521-34, 1981.
-
(1981)
Perception and Psychophysics
, vol.29
, pp. 521-534
-
-
Swesson, R.G.1
Judy, P.F.2
-
35
-
-
0021968255
-
Detection of small focal lesions in CT images: Effects of reconstruction filters and visual display windows
-
P.F.Judy and R.G. Swensson, "Detection of small focal lesions in CT images: effects of reconstruction filters and visual display windows," Br. J. Radiol. 58, 137-45, 1985.
-
(1985)
Br. J. Radiol.
, vol.58
, pp. 137-145
-
-
Judy, P.F.1
Swensson, R.G.2
-
36
-
-
0021336242
-
Digital image processing: Effect on detectability of simulated low-contrast radiographic patterns
-
M. Ishida, K. Doi, L. Loo, C.E. Metz, J.L. Lehr, "Digital image processing: effect on detectability of simulated low-contrast radiographic patterns," Rad. 150, 569-75, 1984.
-
(1984)
Rad.
, vol.150
, pp. 569-575
-
-
Ishida, M.1
Doi, K.2
Loo, L.3
Metz, C.E.4
Lehr, J.L.5
-
37
-
-
0021958024
-
Investigation of basic imaging properties in digital radiography: Effect of pixel size on SNR and threshold contrast
-
M.L. Giger, K. Doi, "Investigation of basic imaging properties in digital radiography: effect of pixel size on SNR and threshold contrast," Med. Phys. 12, 201-8, 1985.
-
(1985)
Med. Phys.
, vol.12
, pp. 201-208
-
-
Giger, M.L.1
Doi, K.2
-
40
-
-
0022135615
-
Effect of noise correlation on detectability of disk signals in medical imaging
-
K.J. Myers, H.H. Barrett, M.C. Borgstrom, D.D. Patton, G.W. Seeley, "Effect of noise correlation on detectability of disk signals in medical imaging," J. Opt. Soc. Am.A 2, 1752-9, 1985.
-
(1985)
J. Opt. Soc. Am.A
, vol.2
, pp. 1752-1759
-
-
Myers, K.J.1
Barrett, H.H.2
Borgstrom, M.C.3
Patton, D.D.4
Seeley, G.W.5
-
41
-
-
0027425561
-
Model observers for assessment of image quality
-
H.H. Barrett, J.Yao, J.P. Rolland, K. Myers, "Model observers for assessment of image quality," Proc. Natl. Acad. Sci. 90, 9758-65, 1993.
-
(1993)
Proc. Natl. Acad. Sci.
, vol.90
, pp. 9758-9765
-
-
Barrett, H.H.1
Yao, J.2
Rolland, J.P.3
Myers, K.4
-
42
-
-
0026861784
-
Effect of random inhomogeneity on observer detection performance
-
J.P. Rolland and H.H. Barrett, "Effect of random inhomogeneity on observer detection performance," J. Opt. Soc. Am.A 9, 649-58, 1992.
-
(1992)
J. Opt. Soc. Am.A
, vol.9
, pp. 649-658
-
-
Rolland, J.P.1
Barrett, H.H.2
-
43
-
-
0033090038
-
Visual signal detection with two-component noise: Low-pass spectrum effect
-
A.E. Burgess, "Visual signal detection with two-component noise: low-pass spectrum effect," J. Opt. Soc. Am.A 16, 694-704, 1999.
-
(1999)
J. Opt. Soc. Am.A
, vol.16
, pp. 694-704
-
-
Burgess, A.E.1
-
44
-
-
0023502720
-
Addition of a channel mechanism to the ideal observer model
-
K.J. Myers, H.H. Barrett, "Addition of a channel mechanism to the ideal observer model, J. Opt. Soc. Am.A, 4, 2447-57, 1987.
-
(1987)
J. Opt. Soc. Am.A
, vol.4
, pp. 2447-2457
-
-
Myers, K.J.1
Barrett, H.H.2
-
45
-
-
0029257694
-
Lesion detection in structured noise
-
M.P. Eckstein and J.S. Whiting, "Lesion detection in structured noise," Academic Radiology, 2, 249-53, 1995.
-
(1995)
Academic Radiology
, vol.2
, pp. 249-253
-
-
Eckstein, M.P.1
Whiting, J.S.2
-
46
-
-
0000466778
-
Practical guide to model observers for visual detection in synthetic and natural noisy images
-
J. Beutter, H.L. Kundel, R.L.Van Metter, eds., SPIE Press
-
M.P. Eckstein, C.K. Abbey, F.O. Bochud, "Practical guide to model observers for visual detection in synthetic and natural noisy images," Handbook of Medical Imaging, Physics and Psychophysics, J. Beutter, H.L. Kundel, R.L.Van Metter, eds., SPIE Press, 2000.
-
(2000)
Handbook of Medical Imaging, Physics and Psychophysics
-
-
Eckstein, M.P.1
Abbey, C.K.2
Bochud, F.O.3
-
47
-
-
0003073581
-
Linear iterative reconstruction algorithms: Study of observer performance
-
Y. Bizais, C. Barillot, and R. Di Paola, eds. (Kluwer Academic, Dordrecht)
-
C.K. Abbey, H.H. Barrett, "Linear iterative reconstruction algorithms: study of observer performance," Proc. 14th Int. Conf. on Information Processing in Medical Imaging, Y. Bizais, C. Barillot, and R. Di Paola, eds. (Kluwer Academic, Dordrecht 1995) 65-76.
-
(1995)
Proc. 14th Int. Conf. on Information Processing in Medical Imaging
, pp. 65-76
-
-
Abbey, C.K.1
Barrett, H.H.2
-
48
-
-
0025846712
-
Observer performance in dynamic displays: Effect of frame rate on visual signal detection in noisy images
-
B.E. Rogowitz, M.H. Brill, J.P. Allenbach, eds.
-
J.S. Whiting, D.A. Honig, E. Carterette, N. Eigler, "Observer performance in dynamic displays: effect of frame rate on visual signal detection in noisy images," Proc. SPIE, Human Vision,Visual Proc. and Digital Display II, B.E. Rogowitz, M.H. Brill, J.P. Allenbach, eds., 1453, 165-75, 1991.
-
(1991)
Proc. SPIE, Human Vision, Visual Proc. and Digital Display II
, vol.1453
, pp. 165-175
-
-
Whiting, J.S.1
Honig, D.A.2
Carterette, E.3
Eigler, N.4
-
49
-
-
0000387046
-
Perceived noise versus display noise in temporally filtered image sequences
-
D.L. Wilson, K.N. Jabri, P. Xue, R. Aufrichtig, "Perceived noise versus display noise in temporally filtered image sequences," Journal of Electronic Imaging 5, 490-5, 1996.
-
(1996)
Journal of Electronic Imaging
, vol.5
, pp. 490-495
-
-
Wilson, D.L.1
Jabri, K.N.2
Xue, P.3
Aufrichtig, R.4
-
50
-
-
0030267578
-
Role of knowledge in human visual temporal integration in spatiotemporal noise
-
M.P. Eckstein, J.P. Thomas, J.S. Whiting, "Role of knowledge in human visual temporal integration in spatiotemporal noise," J. Opt. Soc. Am.A 13, 1960-8, 1996.
-
(1996)
J. Opt. Soc. Am.A
, vol.13
, pp. 1960-1968
-
-
Eckstein, M.P.1
Thomas, J.P.2
Whiting, J.S.3
-
51
-
-
58749092658
-
Comparison of the channelized hotelling and human observers for lesion detection in hepatic SPECT imaging
-
M.A. King, D.J. de Vries, E.J. Soares, "Comparison of the channelized Hotelling and human observers for lesion detection in hepatic SPECT imaging," Proc. SPIE Image Perception, 3036, 14-20, 1997.
-
(1997)
Proc. SPIE Image Perception
, vol.3036
, pp. 14-20
-
-
King, M.A.1
De Vries, D.J.2
Soares, E.J.3
-
52
-
-
0025456621
-
Aperture optimization for emission imaging: Effect of spatially varying background
-
K.J. Myers, J.P. Rolland, H.H. Barrett, R.F.Wagner, "Aperture optimization for emission imaging: effect of spatially varying background," J. Opt. Soc. Am.A 7, 1279-93, 1990.
-
(1990)
J. Opt. Soc. Am.A
, vol.7
, pp. 1279-1293
-
-
Myers, K.J.1
Rolland, J.P.2
Barrett, H.H.3
Wagner, R.F.4
-
53
-
-
0023854818
-
Influence of clinical history upon detection of nodules and other lesions
-
K.S. Berbaum, "Influence of clinical history upon detection of nodules and other lesions," Investigative Radiology, 23, 48-55, 1988.
-
(1988)
Investigative Radiology
, vol.23
, pp. 48-55
-
-
Berbaum, K.S.1
-
54
-
-
0023678636
-
Impact of clinical history on fracture detection with radiography
-
K.S. Berbaum, "Impact of clinical history on fracture detection with radiography," Radiology 168, 507-11, 1988.
-
(1988)
Radiology
, vol.168
, pp. 507-511
-
-
Berbaum, K.S.1
-
55
-
-
0000782221
-
Visual search patterns for radiologists in training
-
E.L. Thomas and E.L. Lansdown, "Visual search patterns for radiologists in training," Radiology 81, 288-91, 1963.
-
(1963)
Radiology
, vol.81
, pp. 288-291
-
-
Thomas, E.L.1
Lansdown, E.L.2
-
56
-
-
0016258045
-
Visual sampling and estimates of the location of information on chest film
-
H.L. Kundel, "Visual sampling and estimates of the location of information on chest film," Invest. Radiology 9, 87-93, 1974.
-
(1974)
Invest. Radiology
, vol.9
, pp. 87-93
-
-
Kundel, H.L.1
-
57
-
-
0018185517
-
Visual scanning, pattern recognition and decision making in pulmonary nodule detection
-
H.L. Kundel, C. F. Nodine and D. Carmody, "Visual scanning, pattern recognition and decision making in pulmonary nodule detection," Invest. Radiology 13, 175-81, 1978.
-
(1978)
Invest. Radiology
, vol.13
, pp. 175-181
-
-
Kundel, H.L.1
Nodine, C.F.2
Carmody, D.3
-
58
-
-
0030075891
-
Visual scanning patterns of radiologists searching mammograms
-
E. Krupinski, "Visual scanning patterns of radiologists searching mammograms," Acad. Radiology 3, 137-44, 1996.
-
(1996)
Acad. Radiology
, vol.3
, pp. 137-144
-
-
Krupinski, E.1
-
59
-
-
0006946951
-
Using eye movements to study decision making of radiologists
-
G. Luer and F. Johnson, eds., (C.H. Hogrefe, New York)
-
C.F. Nodine et al., "Using eye movements to study decision making of radiologists," in G. Luer and F. Johnson, eds., Theoretical & Applied Aspects (C.H. Hogrefe, New York, 1987) 349-63.
-
(1987)
Theoretical & Applied Aspects
, pp. 349-363
-
-
Nodine, C.F.1
-
60
-
-
0001780632
-
Statistical texture synthesis of mammographic images with clustered lumpy backgrounds
-
F.O. Bochud, C.K. Abbey, M.P. Eckstein, "Statistical texture synthesis of mammographic images with clustered lumpy backgrounds," Opt. Express 4, 33-43, 1999.
-
(1999)
Opt. Express
, vol.4
, pp. 33-43
-
-
Bochud, F.O.1
Abbey, C.K.2
Eckstein, M.P.3
|