-
2
-
-
0031230778
-
The DIA anatomic abutment system and telescopic prostheses: A clinical report
-
Preiskel HW, Tsolka P. The DIA anatomic abutment system and telescopic prostheses: A clinical report. Int J Oral Maxillofac Implants 1997;12:628-633.
-
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 628-633
-
-
Preiskel, H.W.1
Tsolka, P.2
-
3
-
-
0031583271
-
The implant in prosthodontics today - A personal viewpoint
-
Preiskel HW, Tsolka P. The implant in prosthodontics today - A personal viewpoint. Br Dent J 1997;182(6):202-205.
-
(1997)
Br Dent J
, vol.182
, Issue.6
, pp. 202-205
-
-
Preiskel, H.W.1
Tsolka, P.2
-
6
-
-
0027616941
-
On clinical loading of osseointegrated implants
-
Glantz P-O, Rangert B, Svensson A, Stafford GD, Arnvidarsson B, Randow K, et al. On clinical loading of osseointegrated implants. Clin Oral Implants Res 1993;4:99-105.
-
(1993)
Clin Oral Implants Res
, vol.4
, pp. 99-105
-
-
Glantz, P.-O.1
Rangert, B.2
Svensson, A.3
Stafford, G.D.4
Arnvidarsson, B.5
Randow, K.6
-
8
-
-
0348233074
-
Biomechanics of in-line vs. offset implants supporting a partial prosthesis
-
abstract #1327
-
Daellenbach K, Hurley E, Brunski JB, Rangert B. Biomechanics of in-line vs. offset implants supporting a partial prosthesis [abstract #1327]. J Dent Res 1996;75(special issue):183.
-
(1996)
J Dent Res
, vol.75
, Issue.SPEC. ISSUE
, pp. 183
-
-
Daellenbach, K.1
Hurley, E.2
Brunski, J.B.3
Rangert, B.4
-
10
-
-
0024237058
-
Studies on frameworks for osseointegrated prostheses. Part 2. The effect of adding acrylic resin or porcelain to form the occlusal superstructure
-
Davis DM, Rimrott R, Zarb GA. Studies on frameworks for osseointegrated prostheses. Part 2. The effect of adding acrylic resin or porcelain to form the occlusal superstructure Int J Oral Maxillofac Implants 1988;3:275-280.
-
(1988)
Int J Oral Maxillofac Implants
, vol.3
, pp. 275-280
-
-
Davis, D.M.1
Rimrott, R.2
Zarb, G.A.3
-
11
-
-
0033158247
-
Influence of mandibular superstructure shape on implant stresses during simulated posterior biting
-
Korioth TW, Johann AR. Influence of mandibular superstructure shape on implant stresses during simulated posterior biting. J Prosthet Dent 1999;82(1):67-72.
-
(1999)
J Prosthet Dent
, vol.82
, Issue.1
, pp. 67-72
-
-
Korioth, T.W.1
Johann, A.R.2
-
12
-
-
0030090665
-
On the influence of superstructure connection on implant preload: A methodological and clinical study
-
Smedberg J-I, Nilner K, Rangert B, Svensson S-A, Glantz P-O. On the influence of superstructure connection on implant preload: A methodological and clinical study. Clin Oral Implants Res 1996;7:55-63.
-
(1996)
Clin Oral Implants Res
, vol.7
, pp. 55-63
-
-
Smedberg, J.-I.1
Nilner, K.2
Rangert, B.3
Svensson, S.-A.4
Glantz, P.-O.5
-
13
-
-
0029377214
-
Accuracy of implant-supported prostheses in the edentulous jaw. Analysis of precision of fit between cast gold-alloy framework and master casts by means of a three-dimensional photogrammatric technique
-
Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw. Analysis of precision of fit between cast gold-alloy framework and master casts by means of a three-dimensional photogrammatric technique. Clin Oral Implants Res 1995;6:172-180.
-
(1995)
Clin Oral Implants Res
, vol.6
, pp. 172-180
-
-
Jemt, T.1
Lie, A.2
-
14
-
-
0030097958
-
In vivo measurement of precision of fit involving implant-supported prostheses in the edentulous jaw
-
Jemt T. In vivo measurement of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996;11:151-158.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 151-158
-
-
Jemt, T.1
-
15
-
-
0030237874
-
Prosthesis misfit and marginal bone loss in edentulous implant patients
-
Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 620-625
-
-
Jemt, T.1
Book, K.2
-
18
-
-
0026921680
-
Fixture design and overload influence marginal bone loss and fixture success in the Brånemark System
-
Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark System. Clin Oral Implants Res 1992;3:104-111.
-
(1992)
Clin Oral Implants Res
, vol.3
, pp. 104-111
-
-
Quirynen, M.1
Naert, I.2
Van Steenberghe, D.3
-
19
-
-
0026740505
-
Biomechanical factors affecting the bone-dental implant interface
-
Brunski JB. Biomechanical factors affecting the bone-dental implant interface. Clin Mater 1992;10:153-201.
-
(1992)
Clin Mater
, vol.10
, pp. 153-201
-
-
Brunski, J.B.1
-
20
-
-
0033630481
-
Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future development
-
Brunski JB, Puleo D, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future development. Int J Oral Maxillofac Implants 2000;15:15-46.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 15-46
-
-
Brunski, J.B.1
Puleo, D.2
Nanci, A.3
-
21
-
-
0348233072
-
Strength characteristics of CP titanium
-
Rangert B, Forsmalm G. Strength characteristics of CP titanium. Nobelpharma News 1994;8(1):7.
-
(1994)
Nobelpharma News
, vol.8
, Issue.1
, pp. 7
-
-
Rangert, B.1
Forsmalm, G.2
|