-
1
-
-
0029266837
-
The canine cemented modular total hip prosthesis
-
Olmstead ML: The canine cemented modular total hip prosthesis. J Am Anim Hosp Assoc 31:109-124, 1995
-
(1995)
J Am Anim Hosp Assoc
, vol.31
, pp. 109-124
-
-
Olmstead, M.L.1
-
2
-
-
84995163219
-
Radiographic evaluation of total hip replacement in the dog
-
Konde LJ, Olmstead ML, Hohn RB: Radiographic evaluation of total hip replacement in the dog. Vet Radiol 23:98-106, 1982
-
(1982)
Vet Radiol
, vol.23
, pp. 98-106
-
-
Konde, L.J.1
Olmstead, M.L.2
Hohn, R.B.3
-
3
-
-
0015632760
-
Prosthetic hip angulation
-
McLaren RH: Prosthetic hip angulation. Radiology 107:705-706, 1973
-
(1973)
Radiology
, vol.107
, pp. 705-706
-
-
McLaren, R.H.1
-
4
-
-
0017859205
-
Dislocations after total hip-replacement arthroplasties
-
Lewinnek GE, Lewis JL, Tarr R, et al: Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60: 217-220, 1978
-
(1978)
J Bone Joint Surg Am
, vol.60
, pp. 217-220
-
-
Lewinnek, G.E.1
Lewis, J.L.2
Tarr, R.3
-
5
-
-
0019409414
-
A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component
-
Visser JD, Konings JG: A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component. J Bone Joint Surg Br 63:556-559, 1981
-
(1981)
J Bone Joint Surg Br
, vol.63
, pp. 556-559
-
-
Visser, J.D.1
Konings, J.G.2
-
6
-
-
0022489328
-
Anteversion of the acetabular cup. Measurement of angle after total hip replacement
-
Ackland MK, Bourne WB, Uhthoff HK: Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409-413, 1986
-
(1986)
J Bone Joint Surg Br
, vol.68
, pp. 409-413
-
-
Ackland, M.K.1
Bourne, W.B.2
Uhthoff, H.K.3
-
7
-
-
0028999144
-
Radiographic calculation of anteversion in acetabular prostheses
-
Hassan DM, Johnston GHF, Dust WNC, et al: Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty 10:369-372, 1995
-
(1995)
J Arthroplasty
, vol.10
, pp. 369-372
-
-
Hassan, D.M.1
Johnston, G.H.F.2
Dust, W.N.C.3
-
8
-
-
0029114941
-
Measurement of acetabular version on the axiolateral radiograph
-
Yao L, Yao J, Gold RH: Measurement of acetabular version on the axiolateral radiograph. Clin Orthop 316:106-111, 1995
-
(1995)
Clin Orthop
, vol.316
, pp. 106-111
-
-
Yao, L.1
Yao, J.2
Gold, R.H.3
-
9
-
-
0016613131
-
Evaluation of acetabular anteversion following total hip arthroplasty: Necessity of proper centring
-
Goergen TD, Resnick D: Evaluation of acetabular anteversion following total hip arthroplasty: Necessity of proper centring. Br J Radiol 48:259-260, 1975
-
(1975)
Br J Radiol
, vol.48
, pp. 259-260
-
-
Goergen, T.D.1
Resnick, D.2
-
10
-
-
84995171777
-
Inclination and anteversion angles of the femoral head and neck in the dog. Evaluation of a standard method of measurement
-
Montavon PM, Hohn RB, Olmstead ML, et al: Inclination and anteversion angles of the femoral head and neck in the dog. Evaluation of a standard method of measurement. Vet Surg 14:277-282, 1985
-
(1985)
Vet Surg
, vol.14
, pp. 277-282
-
-
Montavon, P.M.1
Hohn, R.B.2
Olmstead, M.L.3
-
11
-
-
0009158217
-
Normal joint range of motion in the dog and cat. Appendix B
-
Newton CD, Nunamaker DM (eds): Philadelphia, PA, Lippincott
-
Newton CD: Normal joint range of motion in the dog and cat. Appendix B, in Newton CD, Nunamaker DM (eds): Textbook of Small Animal Orthopaedics. Philadelphia, PA, Lippincott, 1985, pp 1101-1106
-
(1985)
Textbook of Small Animal Orthopaedics
, pp. 1101-1106
-
-
Newton, C.D.1
-
12
-
-
85031469960
-
Component specifications
-
Allendale, NJ, Biomedtrix, Inc
-
Anon: Component specifications, in Biomedtrix canine modular total hip replacement system. Surgical protocol for cemented application. Allendale, NJ, Biomedtrix, Inc, 1996, p 2
-
(1996)
Biomedtrix Canine Modular Total Hip Replacement System. Surgical Protocol for Cemented Application
, pp. 2
-
-
|