메뉴 건너뛰기




Volumn 22, Issue 4, 2001, Pages 370-373

Internal current mark in a case of suicide by electrocution

Author keywords

Current mark; Electrocution; Suicide; Time switch

Indexed keywords

ADULT; ARTICLE; AUTOPSY; CASE REPORT; CAUSE OF DEATH; ELECTRIC CURRENT; ELECTROCOAGULATION; ELECTROCUTION; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; MALE; MUSCLE CONTRACTURE; PERINEURIUM; PLEURA; SKIN MANIFESTATION; SUICIDE;

EID: 0035205914     PISSN: 01957910     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000433-200112000-00007     Document Type: Article
Times cited : (26)

References (28)
  • 4
    • 0013833181 scopus 로고
    • Untersuchungen über histologie und metallisation nach elektrischen einwirkungen auf die haut
    • (1965) Dtsch Z Ger Med , vol.56 , pp. 269-280
    • Schäffner, M.1
  • 24
    • 0032863983 scopus 로고    scopus 로고
    • A histological analysis of a high voltage electric current injury to an upper limb
    • (1999) Burns , vol.25 , pp. 541-547
    • De Bono, R.1