Volumn 74, Issue 8, 2001, Pages 541-548
|
Biomonitoring of exposure to nitrous oxide, sevoflurane, isoflurane and halothane by automated GC/MS headspace urinalysis
a a a a |
Author keywords
Biological monitoring; GC MS; Operating theatre; Volatile anaesthetics
|
Indexed keywords
ANESTHETIC AGENT;
HALOTHANE;
ISOFLURANE;
NITROUS OXIDE;
SEVOFLURANE;
VOLATILE AGENT;
AIR MONITORING;
AIR POLLUTION CONTROL;
ANESTHESIST;
ARTICLE;
ASSAY;
BIOLOGICAL MONITORING;
CONCENTRATION (PARAMETERS);
DATA ANALYSIS;
DRUG DETERMINATION;
ENVIRONMENTAL EXPOSURE;
GAS CHROMATOGRAPHY;
GENERAL ANESTHESIA;
HALOGENATION;
HEALTH SERVICE;
HUMAN;
INDOOR AIR POLLUTION;
ITALY;
LABORATORY AUTOMATION;
MASS SPECTROMETRY;
MEDICAL RESEARCH;
NURSE;
OCCUPATIONAL EXPOSURE;
OCCUPATIONAL SAFETY;
OPERATING ROOM PERSONNEL;
RISK ASSESSMENT;
SENSITIVITY AND SPECIFICITY;
SHIFT WORKER;
SURGEON;
URINALYSIS;
VALIDATION PROCESS;
VAPOR;
|
EID: 0035190456
PISSN: 03400131
EISSN: None
Source Type: Journal
DOI: 10.1007/s004200100263 Document Type: Article |
Times cited : (43)
|
References (21)
|