Volumn 16, Issue 6, 2001, Pages 460-468
|
Low-dose versus high-dose heparinization during arteriovenous carbon dioxide removal
|
Author keywords
[No Author keywords available]
|
Indexed keywords
CARBON DIOXIDE;
FIBRIN DEGRADATION PRODUCT;
HEPARIN;
BIOMATERIAL;
FIBRINOGEN;
ANIMAL EXPERIMENT;
ANIMAL MODEL;
ARTERIOVENOUS SHUNT;
ARTERY;
ARTICLE;
BLEEDING;
BLOOD CARBON DIOXIDE TENSION;
BLOOD CLOTTING TIME;
BLOOD FLOW;
BURN;
CANNULATION;
CAROTID ARTERY;
CONTROLLED STUDY;
DISEASE SEVERITY;
HEART OUTPUT;
HEMATOCRIT;
HEPARINIZATION;
JUGULAR VEIN;
LD 50;
LUNG BURN;
LUNG INJURY;
NONHUMAN;
OXYGENATOR;
PRIORITY JOURNAL;
PROSPECTIVE STUDY;
RANDOMIZATION;
RESPIRATORY DISTRESS;
THROMBOCYTE COUNT;
THROMBOGENESIS;
THROMBOSIS;
ACUTE DISEASE;
ANIMAL;
BLOOD;
BLOOD FLOW VELOCITY;
DISEASE MODEL;
DOSE RESPONSE;
DRUG EFFECT;
EXTRACORPOREAL OXYGENATION;
FEMALE;
METABOLISM;
METHODOLOGY;
RESPIRATORY FAILURE;
SHEEP;
STANDARD;
TREATMENT OUTCOME;
ACUTE DISEASE;
ANIMAL;
ARTERIOVENOUS SHUNT, SURGICAL;
BLOOD FLOW VELOCITY;
CARBON DIOXIDE;
COATED MATERIALS, BIOCOMPATIBLE;
DISEASE MODELS, ANIMAL;
DOSE-RESPONSE RELATIONSHIP, DRUG;
EXTRACORPOREAL MEMBRANE OXYGENATION;
FEMALE;
FIBRINOGEN;
HEPARIN;
OXYGENATORS, MEMBRANE;
PLATELET COUNT;
RESPIRATORY INSUFFICIENCY;
SHEEP;
TREATMENT OUTCOME;
WHOLE BLOOD COAGULATION TIME;
|
EID: 0035177120
PISSN: 02676591
EISSN: None
Source Type: Journal
DOI: 10.1177/026765910101600605 Document Type: Article |
Times cited : (18)
|
References (27)
|