메뉴 건너뛰기




Volumn 457, Issue 1-2, 2001, Pages 75-100

Studies of the response of the prototype CMS hadron calorimeter, including magnetic field effects, to pion, electron, and muon beams

(68)  Abramov, V V a   Acharya, B S b   Akchurin, N n   Atanasov, I c   Baiatian, G r   Ball, A d   Banerjee, S b   De Barbaro, P e   Barnes, V f   Bencze, G g   Bodek, A e   Booke, M h   Budd, H e   Cremaldi, L h   Cushman, P i   Dugad, S R b   Dimitrov, L c   Dyshkant, A e   Elias, J j   Evdokimov, V N a   more..


Author keywords

[No Author keywords available]

Indexed keywords

CALORIMETERS; COMPUTER SIMULATION; COPPER; ELECTRON BEAMS; LEAD COMPOUNDS; MAGNETIC FIELD EFFECTS; MONTE CARLO METHODS; PHOSPHORS;

EID: 0035151259     PISSN: 01689002     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-9002(00)00711-7     Document Type: Article
Times cited : (19)

References (31)
  • 3
    • 85031531231 scopus 로고    scopus 로고
    • Appendix A1 to CMS HCAL TDR, CERN/LHCC 97-31
    • CMS Response Document to LHCC Referees, Appendix A1 to CMS HCAL TDR, CERN/LHCC 97-31, 1997.
    • (1997) CMS Response Document to LHCC Referees
  • 6
    • 0023382867 scopus 로고
    • Status report of the RD5 experiment, CERN-DRDC/93-49
    • M. Aguilar-Benitez et al., Nucl. Instr. and Meth. A 258 (1987) 26; Status report of the RD5 experiment, CERN-DRDC/93-49.
    • (1987) Nucl. Instr. and Meth. a , vol.258 , pp. 26
    • Aguilar-Benitez, M.1
  • 9
    • 0031094120 scopus 로고    scopus 로고
    • The CMS central hadron calorimeter
    • Budd H. The CMS central hadron calorimeter. Nucl. Phys. B (proc. suppl.). 54:1997;191.
    • (1997) Nucl. Phys. B (Proc. Suppl.) , vol.54 , pp. 191
    • Budd, H.1
  • 12
    • 85031529526 scopus 로고    scopus 로고
    • CERN/LHCC 97-31, CMS TDR 2, 20-Jun- and references therein
    • CERN/LHCC 97-31, CMS TDR 2, 20-Jun-1997 and references therein, p. 389.
    • (1997) , pp. 389
  • 23
    • 0033717853 scopus 로고    scopus 로고
    • Precision calibration of the NuTeV calorimeter
    • (NuTeV Collaboration) University of Rochester preprint UR-1561
    • D. Harris, J. Yu et al. (NuTeV Collaboration) Precision calibration of the NuTeV calorimeter, University of Rochester preprint UR-1561; Nucl. Instr. and Meth. A 447(3) (2000).
    • (2000) Nucl. Instr. and Meth. a , vol.447 , Issue.3
    • Harris, D.1    Yu, J.2
  • 25
    • 85031523381 scopus 로고    scopus 로고
    • Test beam performance of the CDF plug upgrade hadron calorimeter
    • Notre Dame, IN, November 4-11
    • P. de Barbaro et al., Test beam performance of the CDF plug upgrade hadron calorimeter, Proceedings of the SCIFI97 Conference, Notre Dame, IN, November 4-11, 1997.
    • (1997) Proceedings of the SCIFI97 Conference
    • De Barbaro, P.1
  • 28
    • 85031535434 scopus 로고
    • PITHA 85/02, Aachen
    • H. Fesefeldt, PITHA 85/02, Aachen, 1985.
    • (1985)
    • Fesefeldt, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.