메뉴 건너뛰기




Volumn 152, Issue 1-2, 2001, Pages 55-66

Cochlear implant thresholds: Comparison of middle latency responses with psychophysical and cortical-spike-activity thresholds

Author keywords

Auditory cortex; Cochlear implant; Electrically evoked middle latency response; Electrode configuration; Phase duration; Psychophysics; Threshold

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; AUDITORY CORTEX; AUDITORY THRESHOLD; BRAIN CELL; COCHLEA PROSTHESIS; CONTROLLED STUDY; ELECTRODE; ELECTROSTIMULATION; EVOKED AUDITORY RESPONSE; EVOKED BRAIN STEM RESPONSE; EVOKED MIDDLE LATENCY RESPONSE; EVOKED RESPONSE; GUINEA PIG; HEARING IMPAIRMENT; INTERMETHOD COMPARISON; LATENT PERIOD; NONHUMAN; PERCEPTIVE THRESHOLD; PRIORITY JOURNAL; PSYCHOPHYSICS; SPIKE;

EID: 0035133282     PISSN: 03785955     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0378-5955(00)00236-7     Document Type: Article
Times cited : (9)

References (42)
  • 2
    • 0025964605 scopus 로고
    • Electrically evoked auditory brainstem response: refractory properties and strength-duration functions
    • (1991) Hear. Res. , vol.51 , pp. 139-147
    • Abbas, P.J.1    Brown, C.J.2
  • 3
    • 84992539513 scopus 로고    scopus 로고
    • Arenberg, J.G., Furukawa, S., Middlebrooks, J.C., 1999. Auditory cortical images of cochlear electrical stimulation. Paper presented at the 1999 Conference on Implantable Auditory Prostheses, Asilomar (Pacific Grove, CA)
  • 5
    • 84992567715 scopus 로고    scopus 로고
    • Arenberg, J.G., Middlebrooks, J., 2000. Cortical responses to multi-channel cochlear implant stimulation. Paper presented at the 23rd Midwinter Meeting of the Association for Research in Otolaryngology, St. Petersberg Beach, FL
  • 17
    • 84992551459 scopus 로고    scopus 로고
    • Mason, S.M., Sheppard, S., Garnham, C.W., Lutman, M.E., O'Donoghue, G.M., Gibbin, K.P., 1994. Improving the relationship of intraoperative EABR thresholds to T-level in young children receiving the Nucleus cochlear implant. In: Hochmair-Desoyer, I. and Hochmair, E. (Eds.), Advances in Cochlear Implants, Manz, Vienna, pp. 44-49
  • 21
    • 84992659843 scopus 로고    scopus 로고
    • Miller, A.L., 2000. Effects of ototoxic deafening and chronic stimulation on auditory-nerve survival and electrical hearing in guinea pigs. Doctoral dissertation, University of Michigan, MI
  • 22
    • 84992665269 scopus 로고    scopus 로고
    • Miller, A.L., Altschuler, R.A., Pfingst, B.E., 2000a. Structure/function relationships in the deafened guinea pig inner ear: Effects of chronic stimulation. Paper presented at the 23rd Midwinter Meeting of the Association for Research in Otolarygnology, St. Petersberg Beach, FL
  • 28
    • 84992659809 scopus 로고    scopus 로고
    • Montney, L.M., Bledsoe, S.J., Pfingst, B., 2000. The relationship between psychophysical and inferior colliculus responses to pulsatile electrical stimulation. Paper presented at the 23rd MidWinter Meeting of the Association for Research in Otolaryngology, St. Petersberg Beach, FL
  • 30
  • 31
    • 0025644521 scopus 로고
    • Changes over time in thresholds for electrical stimulation of the cochlea
    • (1990) Hear. Res. , vol.50 , pp. 225-236
    • Pfingst, B.E.1
  • 35
    • 0027326955 scopus 로고
    • Middle latency responses to electrical stimulation of the auditory nerve in unanaesthetized guinea pigs
    • (1993) Hear. Res. , vol.67 , pp. 69-74
    • Popelar, J.1    Syka, J.2
  • 38
    • 84992600564 scopus 로고    scopus 로고
    • Smith, D.W., Finley, C.C., 1994. Correlations between behavioral and electrophysiologcal measures of cochlear implant function in the cat. In: Hochmair-Desoyer, I., Hochmair, E. (Eds.), Advances in Cochlear Implants. Manz, Wien, pp. 8-16
  • 39
    • 0030829604 scopus 로고    scopus 로고
    • Effects of electrode configuration on psychophysical strength-duration functions for single biphasic electrical stimuli in cats
    • (1997) J. Acoust. Soc. Am. , vol.102 , pp. 2228-2237
    • Smith, D.W.1    Finley, C.C.2
  • 41
    • 84992600988 scopus 로고    scopus 로고
    • Spelman, F.A., Pfingst, B.E., Miller, J.M., 1978. A constant-current stimulator for use with chronic cochlear implants. Paper presented at the Biomedical Symposium, San Diego, CA


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.