메뉴 건너뛰기




Volumn 16, Issue 3, 2001, Pages 369-379

Magnetic-Field Exposures of Cable Splicers in Electrical Network Distribution Vaults

Author keywords

60 HZ Magnetic Field; Electric Utility Workers; Occupational Exposure; Personal Exposure Measurements

Indexed keywords

ARTICLE; DATA ANALYSIS; ELECTRICITY; HUMAN; MAGNETIC FIELD; MEASUREMENT; OCCUPATIONAL EXPOSURE; OCCUPATIONAL HAZARD; OCCUPATIONAL SAFETY; PRIORITY JOURNAL; TELEVISION; WORKER;

EID: 0035123967     PISSN: 1047322X     EISSN: None     Source Type: Journal    
DOI: 10.1080/10473220118938     Document Type: Article
Times cited : (10)

References (5)
  • 1
    • 0030665227 scopus 로고    scopus 로고
    • Magnetic Field Exposures in the Electric Utility Industry Relevant to Occupational Guideline Levels
    • Bracken, T.D., Senior, R.S., Rankin, R.S., et al.: Magnetic Field Exposures in the Electric Utility Industry Relevant to Occupational Guideline Levels. Appl Occup Environ Health 12(11):756-768 (1997).
    • (1997) Appl Occup Environ Health , vol.12 , Issue.11 , pp. 756-768
    • Bracken, T.D.1    Senior, R.S.2    Rankin, R.S.3
  • 2
    • 0030790077 scopus 로고    scopus 로고
    • Summary and Evaluation of Guidelines for Occupational Exposure to Power Frequency Electric and Magnetic Fields
    • Bailey, W.H., Su, S.H., Bracken, T.D., et al.: Summary and Evaluation of Guidelines for Occupational Exposure to Power Frequency Electric and Magnetic Fields. Health Phys 73(3): 433-453 (1997).
    • (1997) Health Phys , vol.73 , Issue.3 , pp. 433-453
    • Bailey, W.H.1    Su, S.H.2    Bracken, T.D.3
  • 4
    • 0343375204 scopus 로고    scopus 로고
    • Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (Up to 300 GHz)
    • International Committee on Non-Ionizing Radiation Protection (ICNIRP). Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (Up to 300 GHz). Health Phys 74(4):1-32 (1998).
    • (1998) Health Phys , vol.74 , Issue.4 , pp. 1-32
  • 5
    • 0033009292 scopus 로고    scopus 로고
    • Numerical Evaluation of 60 Hz Magnetic Induction in the Human Body in Complex Occupational Environments
    • Dawson, T.W., Caputa, K., Stuchly, M.A.: Numerical Evaluation of 60 Hz Magnetic Induction in the Human Body in Complex Occupational Environments. Phys Med Biol 44:1025-1040 (1999).
    • (1999) Phys Med Biol , vol.44 , pp. 1025-1040
    • Dawson, T.W.1    Caputa, K.2    Stuchly, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.