메뉴 건너뛰기




Volumn 24, Issue 2, 2001, Pages 172-182

RV function in stable and unstable VT: Is there a need for hemodynamic monitoring in future defibrillators?

Author keywords

Defibrillators; Hemodynamics; Sensors; Ventricular tachycardia

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CLINICAL ARTICLE; DEFIBRILLATOR; FEMALE; HEART ELECTROPHYSIOLOGY; HEART RIGHT VENTRICLE FUNCTION; HEART VENTRICLE TACHYCARDIA; HEMODYNAMIC MONITORING; HUMAN; MALE; MEAN ARTERIAL PRESSURE; PULSE PRESSURE; SENSOR; TREATMENT PLANNING;

EID: 0035092814     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2001.00172.x     Document Type: Article
Times cited : (10)

References (22)
  • 3
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 5
  • 6
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.1    McNeil, B.2
  • 8
    • 0026773134 scopus 로고
    • Short-term reproducibility over time of right ventricular pulse pressure as a potential hemodynamic sensor for ventricular tachyarrhythmias
    • (1992) PACE , vol.15 , pp. 971-974
    • Ellenbogen, K.A.1    Wood, M.2    Kapadia, K.3
  • 10
    • 0025741690 scopus 로고
    • A prospective study of changes in right ventricular dP/dt during ventricular tachycardia
    • (1990) PACE , vol.14 , pp. 1098-1104
    • Kapadia, K.A.1    Wood, M.2    Lu, B.3
  • 12
    • 0024845707 scopus 로고
    • Continuous right ventricular volume assessment by catheter measurement of impedance for antitachycardia system control
    • (1989) PACE , vol.12 , pp. 1918-1926
    • Khoury, D.1    McAlister, H.2    Wilkoff, B.3
  • 13
    • 0025183236 scopus 로고
    • Comparison of right ventricular impedance, pulse pressure and maximal dP/dt for determination of hemodynamic stability of ventricular arrhythmias associated with coronary artery disease
    • (1990) Am J Cardiol , vol.66 , pp. 575-582
    • Wood, M.1    Ellenbogen, K.A.2    Kapadia, K.3
  • 15
    • 0005757391 scopus 로고
    • Sustained ventricular tachycardia and exercise-induced tachycardia: Hemodynamic differences
    • (1991) PACE , vol.14 , pp. 709
    • Faerestrand, S.1    Ohm, O.-J.2
  • 17
  • 19
    • 0026448128 scopus 로고
    • Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators
    • (1992) PACE , vol.15 , pp. 1667-1673
    • Grimm, W.1    Flores, B.F.2    Marchlinski, F.E.3
  • 21
    • 0028897807 scopus 로고
    • Pacing techniques to terminate ventricular tachycardia
    • (1995) PACE , vol.18 , pp. 592-598
    • Rosenqvist, M.1