메뉴 건너뛰기




Volumn 27, Issue 3, 2001, Pages 399-408

An adaptive template-matching method and its application to the boundary detection of brachial artery ultrasound scans

Author keywords

Adaptive template matching; Flow mediated vasodilation; Ultrasound; Vascular wall

Indexed keywords

BLOOD VESSELS; COMPUTER AIDED ANALYSIS; EDGE DETECTION; SCANNING;

EID: 0035033657     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(00)00349-5     Document Type: Article
Times cited : (19)

References (26)
  • 1
    • 0031145310 scopus 로고    scopus 로고
    • Template matching: Matched spatial filter and beyond
    • Brunelli R., Poggio T. Template matching Matched spatial filter and beyond . Pattern Recognition. 30:(5):1997;751-768.
    • (1997) Pattern Recognition , vol.30 , Issue.5 , pp. 751-768
    • Brunelli, R.1    Poggio, T.2
  • 2
    • 0022808786 scopus 로고
    • A computational approach to edge-detection
    • Canny J. A computational approach to edge-detection. IEEE Trans Pattern Anal Machine Intell. 8:(6):1986;679-698.
    • (1986) IEEE Trans Pattern Anal Machine Intell , vol.8 , Issue.6 , pp. 679-698
    • Canny, J.1
  • 4
    • 0029309556 scopus 로고
    • A pattern-recognition approach to the detection of complex edges
    • Dori D., Haralick R.M. A pattern-recognition approach to the detection of complex edges. Pattern Recognition Lett. 16:(5):1995;517-529.
    • (1995) Pattern Recognition Lett , vol.16 , Issue.5 , pp. 517-529
    • Dori, D.1    Haralick, R.M.2
  • 5
    • 0034195225 scopus 로고    scopus 로고
    • Ultrasound measurement of brachial flow-mediated vasodilator response
    • Fan L., Santago P., Herrington D.M. Ultrasound measurement of brachial flow-mediated vasodilator response. IEEE Trans Med Imag. 19:(6):2000;621-631.
    • (2000) IEEE Trans Med Imag , vol.19 , Issue.6 , pp. 621-631
    • Fan, L.1    Santago, P.2    Herrington, D.M.3
  • 6
    • 0026835074 scopus 로고
    • Constrained restoration and the recovery of discontinuities
    • Geman D., Reynolds G. Constrained restoration and the recovery of discontinuities. IEEE Trans Pattern Anal Machine Intell. 14:(3):1992;367-383.
    • (1992) IEEE Trans Pattern Anal Machine Intell , vol.14 , Issue.3 , pp. 367-383
    • Geman, D.1    Reynolds, G.2
  • 7
    • 0021155688 scopus 로고
    • Digital step edges from zero crossing of 2nd directional-derivatives
    • Haralick R.M. Digital step edges from zero crossing of 2nd directional-derivatives. IEEE Trans Pattern Anal Machine Intell. 6:(1):1984;58-68.
    • (1984) IEEE Trans Pattern Anal Machine Intell , vol.6 , Issue.1 , pp. 58-68
    • Haralick, R.M.1
  • 8
  • 10
    • 0031995997 scopus 로고    scopus 로고
    • Generalization of the EM algorithm for mixture density estimation
    • Kehtarnava N., Nakamura E. Generalization of the EM algorithm for mixture density estimation. Pattern Recognition Lett. 19:(2):1998;133-144.
    • (1998) Pattern Recognition Lett , vol.19 , Issue.2 , pp. 133-144
    • Kehtarnava, N.1    Nakamura, E.2
  • 12
    • 0034135226 scopus 로고    scopus 로고
    • A global energy approach to facet model and its minimization using weighted least-squares
    • Li C.H., Tam P.K.S. A global energy approach to facet model and its minimization using weighted least-squares. Pattern Recognition. 33:(2):2000;281-293.
    • (2000) Pattern Recognition , vol.33 , Issue.2 , pp. 281-293
    • Li, C.H.1    Tam, P.K.S.2
  • 13
    • 0030330268 scopus 로고    scopus 로고
    • Flow-induced vasodilation of the human brachial artery is impaired in patients 40 years of age with coronary artery disease
    • Lieberman E., Gerhard M., et al. Flow-induced vasodilation of the human brachial artery is impaired in patients 40 years of age with coronary artery disease. Am J Cardiol. 78:1996;1210-1214.
    • (1996) Am J Cardiol , vol.78 , pp. 1210-1214
    • Lieberman, E.1    Gerhard, M.2
  • 14
    • 0030153642 scopus 로고    scopus 로고
    • Deformable models in medical image analysis: A survey
    • McInerney T., Terzopoulos D. Deformable models in medical image analysis A survey . Med Image Anal. 1:(2):1996;91-108.
    • (1996) Med Image Anal , vol.1 , Issue.2 , pp. 91-108
    • McInerney, T.1    Terzopoulos, D.2
  • 15
    • 0028465114 scopus 로고
    • The position-orientation masking approach to parametric search for template matching
    • Paglieroni D.W., Ford G.E., Tsujimoto E.M. The position-orientation masking approach to parametric search for template matching. IEEE Trans Pattern Anal Machine Intell. 16:(7):1994;740-747.
    • (1994) IEEE Trans Pattern Anal Machine Intell , vol.16 , Issue.7 , pp. 740-747
    • Paglieroni, D.W.1    Ford, G.E.2    Tsujimoto, E.M.3
  • 16
    • 0031856759 scopus 로고    scopus 로고
    • Non-invasive measurement of endothelial function
    • Playford D.A., Watts G.F. Non-invasive measurement of endothelial function. Clin Exp Pharmacol Physiol. 25:1998;640-643.
    • (1998) Clin Exp Pharmacol Physiol , vol.25 , pp. 640-643
    • Playford, D.A.1    Watts, G.F.2
  • 17
    • 0027659237 scopus 로고
    • Quantification of MR brain images by mixture density and partial volume modeling
    • Santago P., Gage H.D. Quantification of MR brain images by mixture density and partial volume modeling. IEEE Trans Med Imag. 12:(3):1993;566-574.
    • (1993) IEEE Trans Med Imag , vol.12 , Issue.3 , pp. 566-574
    • Santago, P.1    Gage, H.D.2
  • 18
    • 0001635589 scopus 로고    scopus 로고
    • Flow-mediated dilatation in brachial arteries: Computer analysis of ultrasound image sequences
    • Sonka M., Liang W., Lauer R.M. Flow-mediated dilatation in brachial arteries Computer analysis of ultrasound image sequences . CVD Prevention. 1:1998;147-155.
    • (1998) CVD Prevention , vol.1 , pp. 147-155
    • Sonka, M.1    Liang, W.2    Lauer, R.M.3
  • 19
    • 0030026742 scopus 로고    scopus 로고
    • New methods for arterial diameter measurement from B-mode images
    • Stadler R., Karl W., Lees R. New methods for arterial diameter measurement from B-mode images. Ultrasound Med Biol. 22:(1):1996;25-34.
    • (1996) Ultrasound Med Biol , vol.22 , Issue.1 , pp. 25-34
    • Stadler, R.1    Karl, W.2    Lees, R.3
  • 21
    • 0031060811 scopus 로고    scopus 로고
    • Deformable 2-D template matching using orthogonal curves
    • Tagare H.D. Deformable 2-D template matching using orthogonal curves. IEEE Trans Med Imag. 16:(1):1997;108-117.
    • (1997) IEEE Trans Med Imag , vol.16 , Issue.1 , pp. 108-117
    • Tagare, H.D.1
  • 23
    • 0030876387 scopus 로고    scopus 로고
    • Noninvasive assessment of endothelium-dependent flow-mediated dilation of the brachial artery
    • Uehata A., Lieberman E.H., et al. Noninvasive assessment of endothelium-dependent flow-mediated dilation of the brachial artery. Vasc Med. 2:1997;86-92.
    • (1997) Vasc Med , vol.2 , pp. 86-92
    • Uehata, A.1    Lieberman, E.H.2
  • 24
    • 0030446836 scopus 로고    scopus 로고
    • An in vitro evaluation of the line pattern of the near and far walls of the carotid arteries using B-mode ultrasound
    • van Swijndregt A.M. An in vitro evaluation of the line pattern of the near and far walls of the carotid arteries using B-mode ultrasound. Ultrasound Med Biol. 22:1996;1007-1015.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 1007-1015
    • Van Swijndregt, A.M.1
  • 25
    • 0032792880 scopus 로고    scopus 로고
    • Adding ischaemic hand exercise during occlusion of the brachial artery increases the flow-mediated vasodilation in ultrasound studies of endothelial function
    • Wendelhag I., Fagerberg B., Wikstrand J. Adding ischaemic hand exercise during occlusion of the brachial artery increases the flow-mediated vasodilation in ultrasound studies of endothelial function. Clin Physiol. 19:(4):1999;279-283.
    • (1999) Clin Physiol , vol.19 , Issue.4 , pp. 279-283
    • Wendelhag, I.1    Fagerberg, B.2    Wikstrand, J.3
  • 26
    • 0013217860 scopus 로고    scopus 로고
    • Adaptive self-organized template matching of the gray-level feature space for automatic segmentation of multispectral MRI data of the human brain
    • Wismueller A., Dersch D.R., Leinsinger G.L., Ritter H., Hahn K. Adaptive self-organized template matching of the gray-level feature space for automatic segmentation of multispectral MRI data of the human brain. Radiology. 213P:1999;1152.
    • (1999) Radiology , vol.213 , pp. 1152
    • Wismueller, A.1    Dersch, D.R.2    Leinsinger, G.L.3    Ritter, H.4    Hahn, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.