-
1
-
-
0027370108
-
The effect of intensive treatment on the development and progression of long-term complications of insulin-dependent diabetes mellitus
-
The effect of intensive treatment on the development and progression of long-term complications of insulin-dependent diabetes mellitus. N. Engl. J. Med. 329:1993;977-986.
-
(1993)
N. Engl. J. Med.
, vol.329
, pp. 977-986
-
-
-
2
-
-
0032511583
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)
-
Anon Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet. 352:1998;837-853.
-
(1998)
Lancet
, vol.352
, pp. 837-853
-
-
Anon1
-
3
-
-
0032511566
-
Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34)
-
Anon Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34). Lancet. 352:1998;854-865.
-
(1998)
Lancet
, vol.352
, pp. 854-865
-
-
Anon1
-
4
-
-
0023239559
-
Consensus statement on self-monitoring of blood glucose
-
Consensus statement on self-monitoring of blood glucose. Diabetes Care. 10:1987;95-99.
-
(1987)
Diabetes Care
, vol.10
, pp. 95-99
-
-
-
5
-
-
0028158543
-
Consensus statement on self-monitoring of blood glucose
-
Consensus statement on self-monitoring of blood glucose. Diabetes Care. 17:1994;81-86.
-
(1994)
Diabetes Care
, vol.17
, pp. 81-86
-
-
-
6
-
-
0023714852
-
New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose
-
Koschinsky T., Dannehl K., Gries F.A. New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care. 11:1988;619-629.
-
(1988)
Diabetes Care
, vol.11
, pp. 619-629
-
-
Koschinsky, T.1
Dannehl, K.2
Gries, F.A.3
-
8
-
-
0031972738
-
Accuracy of devices used for self-monitoring of blood glucose
-
Johnson R.N., Baker J.R. Accuracy of devices used for self-monitoring of blood glucose. Ann. Clin. Biochem. 35:1998;68-74.
-
(1998)
Ann. Clin. Biochem.
, vol.35
, pp. 68-74
-
-
Johnson, R.N.1
Baker, J.R.2
-
9
-
-
0032892884
-
Analytical error of home glucose monitors: A comparison of 18 systems
-
Johnson R.N., Baker J.R. Analytical error of home glucose monitors: a comparison of 18 systems. Ann. Clin. Biochem. 36:1999;72-79.
-
(1999)
Ann. Clin. Biochem.
, vol.36
, pp. 72-79
-
-
Johnson, R.N.1
Baker, J.R.2
-
10
-
-
0028998446
-
The Yellow Springs analyser gives lower results than other glucose oxidase methods of glucose measurement
-
Unwin N., Skillen A., Alberti K.G.M.M. The Yellow Springs analyser gives lower results than other glucose oxidase methods of glucose measurement. Ann. Clin. Biochem. 32:1995;329-331.
-
(1995)
Ann. Clin. Biochem.
, vol.32
, pp. 329-331
-
-
Unwin, N.1
Skillen, A.2
Alberti, K.G.M.M.3
-
11
-
-
0015545686
-
Use and interpretation of common statistical tests in method-comparison studies
-
Westgaard J.O., Hunt M.R. Use and interpretation of common statistical tests in method-comparison studies. Clin. Chem. 19:1973;49-57.
-
(1973)
Clin. Chem.
, vol.19
, pp. 49-57
-
-
Westgaard, J.O.1
Hunt, M.R.2
|