메뉴 건너뛰기




Volumn 94, Issue 1-2, 2001, Pages 193-196

Staff dosimetry protocols in interventional radiology

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; DOSIMETER; DOSIMETRY; FLUOROSCOPY; HEALTH CARE PERSONNEL; HUMAN; IMAGING SYSTEM; INTERVENTIONAL RADIOLOGY; NECK; PERSONNEL RADIATION MONITORING; PROTECTIVE CLOTHING; RADIATION EXPOSURE; RADIATION PROTECTION; X RAY TUBE;

EID: 0035030155     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a006471     Document Type: Article
Times cited : (36)

References (25)
  • 1
    • 0030978457 scopus 로고    scopus 로고
    • Radiation Protection in Interventional Radiology
    • Faulkner, K. Radiation Protection in Interventional Radiology. Br.J. Radiol. 70, 325-326 (1997).
    • (1997) Br.J. Radiol. , vol.70 , pp. 325-326
    • Faulkner, K.1
  • 3
    • 0032413186 scopus 로고    scopus 로고
    • Radiation Exposure to Medical Staff in Interventional Radiology
    • Williams, J. R. Radiation Exposure to Medical Staff in Interventional Radiology. Br. J. Radiol. 71, 1333-1334 (1998).
    • (1998) Br. J. Radiol. , vol.71 , pp. 1333-1334
    • Williams, J.R.1
  • 4
    • 0026595589 scopus 로고
    • A 5-year Follow-up of the Radiation Exposure to in-room Personnel during Cardiac Catheterization
    • Renaud, L. A 5-year Follow-up of the Radiation Exposure to in-room Personnel during Cardiac Catheterization. Health Phys. 62, 10-15 (1992).
    • (1992) Health Phys. , vol.62 , pp. 10-15
    • Renaud, L.1
  • 5
    • 0029021158 scopus 로고
    • Patient and Staff Dosimetry in Neuroradiological Procedures
    • Marshall, N.W., Noble, J. and Faulkner, K. Patient and Staff Dosimetry in Neuroradiological Procedures. Br. J. Radiol. 68, 495-501 (1995).
    • (1995) Br. J. Radiol. , vol.68 , pp. 495-501
    • Marshall, N.W.1    Noble, J.2    Faulkner, K.3
  • 10
    • 0023829743 scopus 로고
    • Estimation of Effective Dose Equivalent to Staff in Diagnostic Radiology
    • Faulkner, K. and Harrison, R. M. Estimation of Effective Dose Equivalent to Staff in Diagnostic Radiology. Phys. Med. Biol. 33, 83-91 (1988).
    • (1988) Phys. Med. Biol. , vol.33 , pp. 83-91
    • Faulkner, K.1    Harrison, R.M.2
  • 11
    • 0027223432 scopus 로고
    • The Relationship of Effective Dose to Personnel and Monitor Reading for Simulated Fluoroscopic Irradiation Conditions
    • Faulkner, K. and Marshall, N. W. The Relationship of Effective Dose to Personnel and Monitor Reading for Simulated Fluoroscopic Irradiation Conditions. Health Phys. 64(5), 502-508 (1993).
    • (1993) Health Phys. , vol.64 , Issue.5 , pp. 502-508
    • Faulkner, K.1    Marshall, N.W.2
  • 12
    • 0028282956 scopus 로고
    • Effective Dose to Personnel wearing Protective Aprons during Fluoroscopy and Interventional Radiology
    • Rosenstein, M. and Webster, E. W. Effective Dose to Personnel wearing Protective Aprons during Fluoroscopy and Interventional Radiology. Health Phys. 67, 88-89 (1994).
    • (1994) Health Phys. , vol.67 , pp. 88-89
    • Rosenstein, M.1    Webster, E.W.2
  • 13
    • 0024652195 scopus 로고
    • EDE for Exposure with Protective Aprons
    • Webster, E. W. EDE for Exposure with Protective Aprons. Health Phys. 56, 568-569 (1989).
    • (1989) Health Phys. , vol.56 , pp. 568-569
    • Webster, E.W.1
  • 14
    • 0030910907 scopus 로고    scopus 로고
    • Phantom-derived Estimation of Effective Dose Equivalent from X rays with and without a Lead Apron
    • Mateya, C. F. and Claycamp, H. G. Phantom-derived Estimation of Effective Dose Equivalent from X rays with and without a Lead Apron. Health Phys. 72(6), 842-847 (1997).
    • (1997) Health Phys. , vol.72 , Issue.6 , pp. 842-847
    • Mateya, C.F.1    Claycamp, H.G.2
  • 15
    • 0032038630 scopus 로고    scopus 로고
    • Comment on "Phantom-derived Estimation of Effective Dose Equivalent from X rays with and without a Lead Apron"
    • Rosenstein, M. Comment on "Phantom-derived Estimation of Effective Dose Equivalent from X rays with and without a Lead Apron". Health Phys. 74(4), 489-490 (1998).
    • (1998) Health Phys. , vol.74 , Issue.4 , pp. 489-490
    • Rosenstein, M.1
  • 16
    • 14344274102 scopus 로고    scopus 로고
    • Response to Rosenstein
    • Mateya, C. F. and Claycamp, H. G. Response to Rosenstein. Health Phys. 74(4), 490-491 (1998).
    • (1998) Health Phys. , vol.74 , Issue.4 , pp. 490-491
    • Mateya, C.F.1    Claycamp, H.G.2
  • 17
    • 0032902475 scopus 로고    scopus 로고
    • Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part I: Assessment of Entrance Doses
    • Kicken, P. J. H., Kemerink, G. J. and Engelshoven J. M. A. Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part I: Assessment of Entrance Doses. Radiat. Prot. Dosim. 82(2), 93-103 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.82 , Issue.2 , pp. 93-103
    • Kicken, P.J.H.1    Kemerink, G.J.2    Engelshoven, J.M.A.3
  • 18
    • 0032905648 scopus 로고    scopus 로고
    • Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part II: Assessment of Effective Dose
    • Kicken, P. J. H., Kemerink, G. J., Schultz, F. W. and Zoetelief J. Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part II: Assessment of Effective Dose. Radiat. Prot. Dosim. 82(2), 105-114 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.82 , Issue.2 , pp. 105-114
    • Kicken, P.J.H.1    Kemerink, G.J.2    Schultz, F.W.3    Zoetelief, J.4
  • 19
    • 0028061895 scopus 로고
    • The Estimation of Occupational Effective Dose in Diagnostic Radiology with Two Dosimeters
    • Niklason, L. T., Marx, M. V. and Chan, H. P. The Estimation of Occupational Effective Dose in Diagnostic Radiology with Two Dosimeters. Health Phys. 67(6), 611-615 (1994).
    • (1994) Health Phys. , vol.67 , Issue.6 , pp. 611-615
    • Niklason, L.T.1    Marx, M.V.2    Chan, H.P.3
  • 20
    • 0027278553 scopus 로고
    • Interventional Radiologists: Occupational Radiation Doses and Risks
    • Niklason, L. T., Marx, M. V. and Chan, H. P. Interventional Radiologists: Occupational Radiation Doses and Risks. Radiology 187, 729-733 (1993).
    • (1993) Radiology , vol.187 , pp. 729-733
    • Niklason, L.T.1    Marx, M.V.2    Chan, H.P.3
  • 21
    • 0004035444 scopus 로고
    • Patient Dosimetry Techniques in Diagnostic Radiology
    • Oxford: Bocardo Press
    • Wall, B. F., Harrison, R. M. and Spiers, F. W. Patient Dosimetry Techniques in Diagnostic Radiology. IPSM Report 53 (Oxford: Bocardo Press) (1988).
    • (1988) IPSM Report , vol.53
    • Wall, B.F.1    Harrison, R.M.2    Spiers, F.W.3
  • 22
    • 0019453564 scopus 로고
    • Central Axis Depth Dose Data for Diagnostic Radiology
    • Harrison, R. M. Central Axis Depth Dose Data for Diagnostic Radiology. Phys. Med. Biol. 26, 657-670 (1981).
    • (1981) Phys. Med. Biol. , vol.26 , pp. 657-670
    • Harrison, R.M.1
  • 23
    • 0027485391 scopus 로고
    • Guidelines for Personnel Radiation Monitoring in the Cardiac Cathelerization Laboratory
    • Balter, S. Guidelines for Personnel Radiation Monitoring in the Cardiac Cathelerization Laboratory. Cathet. Cardiovasc. Diagn. 30(4), 277-279 (1993).
    • (1993) Cathet. Cardiovasc. Diagn. , vol.30 , Issue.4 , pp. 277-279
    • Balter, S.1
  • 24
    • 0027892057 scopus 로고
    • Radioprotection in Radiology, a Controversial Practice: How to wear the Individual Dosimeters?
    • Wambersie, A. and Delhove, J. Radioprotection in Radiology, a Controversial Practice: How to wear the Individual Dosimeters? J. Belge Radiol. 76(6), 382-385 (1993).
    • (1993) J. Belge Radiol. , vol.76 , Issue.6 , pp. 382-385
    • Wambersie, A.1    Delhove, J.2
  • 25
    • 0027467454 scopus 로고
    • Factors Affecting the Radiation Dose to the Lens of the Eye during Catheterization Procedures
    • Pratt, T. A. and Shaw, A. J. Factors Affecting the Radiation Dose to the Lens of the Eye during Catheterization Procedures. Br. J. Radiol. 66, 346-350 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 346-350
    • Pratt, T.A.1    Shaw, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.