메뉴 건너뛰기




Volumn 141, Issue 5, 2001, Pages 837-846

Use of routine functional testing after percutaneous transluminal coronary angioplasty: Results from the ROSETTA registry

(15)  Eisenberg, Mark J a   Schechter, David b   Lefkovits, Jeffrey c   Goudreau, Evelyne d   Deligonul, Ubeydullah e   Mak, Koon Hou f   Del Core, Michael g   Duerr, Robert h   Garzon, Philippe M a   Huynh, Thao i   Smilovitch, Mark j   Sedlis, Steven k   Brown, David L l   Brieger, David m   Pilote, Louise a  


Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVASCULAR DISEASE; CLINICAL TRIAL; CORONARY ARTERY DISEASE; EXERCISE TEST; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; PRIORITY JOURNAL; PROSPECTIVE STUDY; TRANSLUMINAL CORONARY ANGIOPLASTY; TREADMILL EXERCISE; TREATMENT OUTCOME;

EID: 0035028553     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1067/mhj.2001.114373     Document Type: Article
Times cited : (18)

References (26)
  • 6
    • 0030787769 scopus 로고    scopus 로고
    • ACC/AHA guidelines for exercise testing: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing)
    • (1997) J Am Coll Cardiol , vol.30 , pp. 260-315
    • Gibbons, R.J.1    Balady, G.J.2    Beasley, J.W.3
  • 10
    • 0028084471 scopus 로고
    • Detection of restenosis following percutaneous coronary angioplasty in single-vessel coronary artery disease: The value of clinical assessment and exercise tolerance testing
    • (1994) Cardiology , vol.84 , pp. 106-113
    • Roth, A.1    Miller, H.I.2    Keren, G.3
  • 11
    • 0030856285 scopus 로고    scopus 로고
    • Accuracy of treadmill exercise electrocardiography in detecting restenosis following single-vessel percutaneous transluminal coronary angioplasty
    • (1997) Am J Cardiol , vol.80 , pp. 1282-1286
    • Koide, Y.1    Yotsukura, M.2    Ando, H.3
  • 18
    • 0027214969 scopus 로고
    • Exercise thallium scintigraphy versus high-dose dipyridamole echocardiography testing for asymptomatic restenosis patients with positive exercise tests after coronary angioplasty
    • (1993) Am J Cordial , vol.71 , pp. 1052-1056
    • Pirelli, S.1    Danzi, G.B.2    Massa, D.3
  • 19
    • 0027404020 scopus 로고
    • Usefulness of supine bicycle stress echocardiography for detection of restenosis after percutaneous transluminal coronary angioplasty
    • (1993) Am J Cardiol , vol.71 , pp. 293-296
    • Hecht, H.S.1    DeBord, L.2    Shaw, R.3
  • 21
    • 0025779616 scopus 로고
    • Comparison of usefulness of high-dose dipyridamole echocardiography and exercise electrocardiography for detection of asymptomatic restenosis after coronary angioplasty
    • (1991) Am J Cardiol , vol.67 , pp. 1335-1338
    • Pirelli, S.1    Danzi, G.B.2    Alberti, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.