-
1
-
-
0025579162
-
Clinical assessment of cardiac output
-
1 Conway J. Clinical assessment of cardiac output. Eur Heart J 1990; 11:148-150.
-
(1990)
Eur Heart J
, vol.11
, pp. 148-150
-
-
Conway, J.1
-
2
-
-
0031949574
-
Cardiac output in 1998
-
2 Singer M. Cardiac output in 1998. Heart 1998; 79: 425-428.
-
(1998)
Heart
, vol.79
, pp. 425-428
-
-
Singer, M.1
-
3
-
-
0022545337
-
Cardiac output estimates in the pediatric intensive care unit using a continuous-wave Doppler computer: Validation and limitations of the technique
-
3 Rein AJJT, Hsieh KS, Elixson M et al. Cardiac output estimates in the pediatric intensive care unit using a continuous-wave Doppler computer: validation and limitations of the technique. Am Heart J 1986; 112: 97-103.
-
(1986)
Am Heart J
, vol.112
, pp. 97-103
-
-
Rein, A.J.J.T.1
Hsieh, K.S.2
Elixson, M.3
-
4
-
-
0021323790
-
Determination of cardiac output by Doppler echocardiography
-
4 Ihlen H, Amlie JP, Dale J et al. Determination of cardiac output by Doppler echocardiography. Br Heart J 1984; 51: 54-60.
-
(1984)
Br Heart J
, vol.51
, pp. 54-60
-
-
Ihlen, H.1
Amlie, J.P.2
Dale, J.3
-
5
-
-
0027934248
-
Cardiac function in healthy infants and children: Doppler echocardiographic evaluation
-
5 Hanseus K, Björkhem G, Lundström NR. Cardiac function in healthy infants and children: Doppler echocardiographic evaluation. Pediatr Cardiol 1994; 15: 211-218.
-
(1994)
Pediatr Cardiol
, vol.15
, pp. 211-218
-
-
Hanseus, K.1
Björkhem, G.2
Lundström, N.R.3
-
6
-
-
0026077875
-
Doppler-derived mean aortic flow velocity in children: An alternative to cardiac index
-
6 Seear MD, D'Orsogna L, Sandor GGS et al. Doppler-derived mean aortic flow velocity in children: an alternative to cardiac index. Pediatr Cardiol 1991; 12: 197-200.
-
(1991)
Pediatr Cardiol
, vol.12
, pp. 197-200
-
-
Seear, M.D.1
D'Orsogna, L.2
Sandor, G.G.S.3
-
7
-
-
0019942435
-
Noninvasive pulsed Doppler determination of cardiac output in neonates and children
-
7 Alverson DC, Eldridge M, Dillon T et al. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 1982; 101: 46-50.
-
(1982)
J Pediatr
, vol.101
, pp. 46-50
-
-
Alverson, D.C.1
Eldridge, M.2
Dillon, T.3
-
8
-
-
0023686128
-
A comparative study of cardiac output measurement by dye dilution and pulsed Doppler ultrasound
-
8 Tibballs J, Osborne A, Hockmann M. A comparative study of cardiac output measurement by dye dilution and pulsed Doppler ultrasound. Anaesth Intens Care 1988; 16; 272-277.
-
(1988)
Anaesth Intens Care
, vol.16
, pp. 272-277
-
-
Tibballs, J.1
Osborne, A.2
Hockmann, M.3
-
9
-
-
0023606071
-
Doppler determination of cardiac output in infants and children: Comparison with simultaneous thermodilution
-
9 Mellander M, Sabel KG, Caidahl K et al. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol 1987; 8: 241-246.
-
(1987)
Pediatr Cardiol
, vol.8
, pp. 241-246
-
-
Mellander, M.1
Sabel, K.G.2
Caidahl, K.3
-
11
-
-
0028959312
-
Cardiac index quantification by Doppler ultrasound in patients without left ventricular outflow tract abnormalities
-
11 Evangelista A, Garcia-Dorado D, Garcia del Castillo H et al. Cardiac index quantification by Doppler ultrasound in patients without left ventricular outflow tract abnormalities. J Am Coll Cardiol 1995; 25: 710-716.
-
(1995)
J Am Coll Cardiol
, vol.25
, pp. 710-716
-
-
Evangelista, A.1
Garcia-Dorado, D.2
Garcia Del Castillo, H.3
-
13
-
-
0029928910
-
A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination
-
13 Keyl C, Rödig G, Lemberger P et al. A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination. Eur J Anaesthesiol 1996; 13: 136-132.
-
(1996)
Eur J Anaesthesiol
, vol.13
, pp. 136-1132
-
-
Keyl, C.1
Rödig, G.2
Lemberger, P.3
-
14
-
-
0025060164
-
Inconsistent oesophageal Doppler cardiac output during acute blood loss
-
14 Kamal GD, Symren T, Starr J. Inconsistent oesophageal Doppler cardiac output during acute blood loss. Anesthesiology 1990; 72: 95-99.
-
(1990)
Anesthesiology
, vol.72
, pp. 95-99
-
-
Kamal, G.D.1
Symren, T.2
Starr, J.3
-
15
-
-
0028884699
-
Non-invasive continuous haemodynamic and PETCO2 monitoring during peroperative cardiac arrest
-
15 Gueugniaud PY, Muchada R, Bertin-Maghit M et al. Non-invasive continuous haemodynamic and PETCO2 monitoring during peroperative cardiac arrest. Can J Anaesth 1995; 42: 910-913.
-
(1995)
Can J Anaesth
, vol.42
, pp. 910-913
-
-
Gueugniaud, P.Y.1
Muchada, R.2
Bertin-Maghit, M.3
-
16
-
-
0030690204
-
Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants
-
16 Gueugniaud PY, Muchada R, Moussa M et al. Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants. Can J Anaesth 1997; 44: 745-750.
-
(1997)
Can J Anaesth
, vol.44
, pp. 745-750
-
-
Gueugniaud, P.Y.1
Muchada, R.2
Moussa, M.3
-
17
-
-
0031938186
-
The hemodynamic effects of pneumoperitoneum during laparoscopic surgery in healthy infants: Assessment by continuous esophageal aortic blood flow echo-Doppler
-
17 Gueugniaud PY, Abisseror M, Moussa M et al. The hemodynamic effects of pneumoperitoneum during laparoscopic surgery in healthy infants: assessment by continuous esophageal aortic blood flow echo-Doppler. Anesth Analg 1998; 86: 290-293.
-
(1998)
Anesth Analg
, vol.86
, pp. 290-293
-
-
Gueugniaud, P.Y.1
Abisseror, M.2
Moussa, M.3
-
18
-
-
0031740374
-
Non-invasive aortic blood flow measurement in infants during repair of craniosynostosis
-
18 Orliaguet GA, Meyer PG, Blanot S et al. Non-invasive aortic blood flow measurement in infants during repair of craniosynostosis. Br J Anaesth 1998; 81: 696-701.
-
(1998)
Br J Anaesth
, vol.81
, pp. 696-701
-
-
Orliaguet, G.A.1
Meyer, P.G.2
Blanot, S.3
-
19
-
-
0031775372
-
Comparison of myocardial effects of desflurane and isoflurane in healthy patients: Assessment by continuous oesophageal aortic blood flow echo-Doppler
-
19 Gueugniaud PY, Vaudelin G, Berthin-Maghit M et al. Comparison of myocardial effects of desflurane and isoflurane in healthy patients: assessment by continuous oesophageal aortic blood flow echo-Doppler. Br J Anaesth 1998; 81: 844-849.
-
(1998)
Br J Anaesth
, vol.81
, pp. 844-849
-
-
Gueugniaud, P.Y.1
Vaudelin, G.2
Berthin-Maghit, M.3
-
20
-
-
0023628146
-
Number of cardiac cycles required to accurately determine mean velocity of blood flow in the ascending aorta and pulmonary trunk
-
20 Kristensen BO, Goldberg SJ. Number of cardiac cycles required to accurately determine mean velocity of blood flow in the ascending aorta and pulmonary trunk. Am J Cardiol 1987; 60: 746-747.
-
(1987)
Am J Cardiol
, vol.60
, pp. 746-747
-
-
Kristensen, B.O.1
Goldberg, S.J.2
-
21
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
21 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8: 307-310.
-
(1986)
Lancet
, vol.8
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
22
-
-
0021742164
-
Reproducibility of Doppler aortic blood flow measurements; studies on intraobserver, interobserver and day-to-day variability in normal subject
-
22 Gardin JM, Dabestani A, Matin K et al. Reproducibility of Doppler aortic blood flow measurements; studies on intraobserver, interobserver and day-to-day variability in normal subject. Am J Cardiol 1984; 54: 1092-1098.
-
(1984)
Am J Cardiol
, vol.54
, pp. 1092-1098
-
-
Gardin, J.M.1
Dabestani, A.2
Matin, K.3
-
23
-
-
0028241431
-
Descending aortic blood flow velocity as a noninvasive measure of cardiac output in children
-
23 Seear M, Webber S, Leblanc J. Descending aortic blood flow velocity as a noninvasive measure of cardiac output in children. Pediatr Cardiol 1994; 15: 178-183.
-
(1994)
Pediatr Cardiol
, vol.15
, pp. 178-183
-
-
Seear, M.1
Webber, S.2
Leblanc, J.3
-
24
-
-
0027521895
-
Characterization of the aortic echo-Doppler profile in normal children during maximal treadmill exercise
-
24 Cyran SE, Grzeszczak M, Haas JH et al. Characterization of the aortic echo-Doppler profile in normal children during maximal treadmill exercise. Am Heart J 1993; 126: 1024-1029.
-
(1993)
Am Heart J
, vol.126
, pp. 1024-1029
-
-
Cyran, S.E.1
Grzeszczak, M.2
Haas, J.H.3
-
25
-
-
0027195618
-
Cardiovascular effects of i.v. induction in children: Comparison between propofol and thiopentone
-
25 Aun CS, Sung RY, O'Meara ME et al. Cardiovascular effects of i.v. induction in children: comparison between propofol and thiopentone. Br J Anaesth 1993; 70: 647-653.
-
(1993)
Br J Anaesth
, vol.70
, pp. 647-653
-
-
Aun, C.S.1
Sung, R.Y.2
O'Meara, M.E.3
-
26
-
-
0024470793
-
Haemodynamic effects of rectal methohexitone for induction of anaesthesia in children
-
26 Forbes RB, Murray DJ, Dull DL et al. Haemodynamic effects of rectal methohexitone for induction of anaesthesia in children. Can J Anaesth 1989; 36: 526-529.
-
(1989)
Can J Anaesth
, vol.36
, pp. 526-529
-
-
Forbes, R.B.1
Murray, D.J.2
Dull, D.L.3
-
27
-
-
0026697122
-
Changes in cardiac index and estimated systemic vascular resistance during induction of anaesthesia with thiopentone, methohexitone, propofol and etomidate
-
27 Price ML, Millar B, Grounds M et al. Changes in cardiac index and estimated systemic vascular resistance during induction of anaesthesia with thiopentone, methohexitone, propofol and etomidate. Br J Anaesth 1992; 69: 172-176.
-
(1992)
Br J Anaesth
, vol.69
, pp. 172-176
-
-
Price, M.L.1
Millar, B.2
Grounds, M.3
-
28
-
-
0021922190
-
Pulmonary and sytemic hemodynamic responses to kétamine in infants with normal and elevated pulmonary vascular resistance
-
28 Hickey PR, Hansen DD, Cramolini GM et al. Pulmonary and sytemic hemodynamic responses to kétamine in infants with normal and elevated pulmonary vascular resistance. Anesthesiology 1985; 62: 287-293.
-
(1985)
Anesthesiology
, vol.62
, pp. 287-293
-
-
Hickey, P.R.1
Hansen, D.D.2
Cramolini, G.M.3
-
29
-
-
0025761587
-
Cardiodynamic effects of propofol in comparison with thiopental: Assessment with a transesophageal echocardiographic approach
-
29 Mulier JP, Wouters PF, Van Aken H et al. Cardiodynamic effects of propofol in comparison with thiopental: assessment with a transesophageal echocardiographic approach. Anesth Analg 1991; 72: 28-35.
-
(1991)
Anesth Analg
, vol.72
, pp. 28-35
-
-
Mulier, J.P.1
Wouters, P.F.2
Van Aken, H.3
-
30
-
-
0022545231
-
Continuous noninvasive monitoring of cardiac ouput with esophageal Doppler ultrasound during cardiac surgery
-
30 Mark JB, Steinbrook RA, Gugino LD et al. Continuous noninvasive monitoring of cardiac ouput with esophageal Doppler ultrasound during cardiac surgery. Anesth Analg 1986; 65: 1013-1020.
-
(1986)
Anesth Analg
, vol.65
, pp. 1013-1020
-
-
Mark, J.B.1
Steinbrook, R.A.2
Gugino, L.D.3
-
31
-
-
0024394464
-
Continuous hemodynamic monitoring by esophageal doppler
-
31 Singer M, Clarke J, Bennett D. Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med 1989; 17: 447-452.
-
(1989)
Crit Care Med
, vol.17
, pp. 447-452
-
-
Singer, M.1
Clarke, J.2
Bennett, D.3
-
32
-
-
0024419202
-
Noninvasive measurement of cardiac output during surgery using a new continuous-wave doppler esophageal probe
-
32 Kumar A, Minagoe S, Thangathurai D et al. Noninvasive measurement of cardiac output during surgery using a new continuous-wave doppler esophageal probe. Am J Cardiol 1989; 64: 793-798.
-
(1989)
Am J Cardiol
, vol.64
, pp. 793-798
-
-
Kumar, A.1
Minagoe, S.2
Thangathurai, D.3
-
33
-
-
0025697265
-
Transesophageal Doppler ultrasonography: Evidence for improved cardiac output monitoring
-
33 Perrino AC, Fleming J, LaMantia KR. Transesophageal Doppler ultrasonography: evidence for improved cardiac output monitoring. Anesth Analg 1990; 71: 651-657.
-
(1990)
Anesth Analg
, vol.71
, pp. 651-657
-
-
Perrino, A.C.1
Fleming, J.2
LaMantia, K.R.3
-
34
-
-
0025833943
-
Transesophageal Doppier cardiac ouput monitoring: Performance during aortic reconstructive surgery
-
34 Perrino AC, Fleming J, LaMantia KR. Transesophageal Doppier cardiac ouput monitoring: performance during aortic reconstructive surgery. Anesth Analg 1991; 73: 705-710.
-
(1991)
Anesth Analg
, vol.73
, pp. 705-710
-
-
Perrino, A.C.1
Fleming, J.2
LaMantia, K.R.3
-
35
-
-
0025947060
-
Noninvasive optimization of left ventricular filling using esophageal Doppler
-
35 Singer M, Bennett ED. Noninvasive optimization of left ventricular filling using esophageal Doppler. Crit Care Med 1991; 19: 1132-1137.
-
(1991)
Crit Care Med
, vol.19
, pp. 1132-1137
-
-
Singer, M.1
Bennett, E.D.2
-
36
-
-
4243848580
-
Cardiac output (CO) measurement; comparison of oesophageal Doppler (ED) vs thermodilution (TD)
-
36 Lefrant JY, de la Coussaye JE, Aya G et al. Cardiac output (CO) measurement; comparison of oesophageal Doppler (ED) vs thermodilution (TD). Br J Anaesth 1993; 70: A18.
-
(1993)
Br J Anaesth
, vol.70
-
-
Lefrant, J.Y.1
De La Coussaye, J.E.2
Aya, G.3
-
37
-
-
0027377406
-
Reliability of new generation transesophageal Doppler device for cardiac output monitoring
-
37 Schmid ER, Spahn DR, Tornic M. Reliability of new generation transesophageal Doppler device for cardiac output monitoring. Anesth Analg 1993; 77: 971-979.
-
(1993)
Anesth Analg
, vol.77
, pp. 971-979
-
-
Schmid, E.R.1
Spahn, D.R.2
Tornic, M.3
-
38
-
-
0029054966
-
Continuous measurement of cardiac output during aortic cross-clamping by oesophageal Doppler Monitor ODM1
-
38 Klotz KF, Klingsiek S, Singer M et al. Continuous measurement of cardiac output during aortic cross-clamping by oesophageal Doppler Monitor ODM1. Br J Anaesth 1995; 74: 655-660.
-
(1995)
Br J Anaesth
, vol.74
, pp. 655-660
-
-
Klotz, K.F.1
Klingsiek, S.2
Singer, M.3
-
39
-
-
4243836595
-
JM. Does oesophageal doppler accurately assess hemodynamic parameters in patients with aortic stenosis
-
39 Catogni P, Provenchere S, Philip I et al. JM. Does oesophageal doppler accurately assess hemodynamic parameters in patients with aortic stenosis. Anesthesiology 1997; 87: A399.
-
(1997)
Anesthesiology
, vol.87
-
-
Catogni, P.1
Provenchere, S.2
Philip, I.3
-
40
-
-
0030879480
-
The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor
-
40 Krishnamurthy B, McMurray TJ, McClean E. The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor. Anaesthesia 1997; 52: 624-629.
-
(1997)
Anaesthesia
, vol.52
, pp. 624-629
-
-
Krishnamurthy, B.1
McMurray, T.J.2
McClean, E.3
-
41
-
-
0021882615
-
Noninvasive aortic blood flow measurement using an intraesophageal probe
-
41 Lavandier B, Cathignol D, Muchada R et al. Noninvasive aortic blood flow measurement using an intraesophageal probe. Ultrasound Med Biol 1985; 3: 451-460.
-
(1985)
Ultrasound Med Biol
, vol.3
, pp. 451-460
-
-
Lavandier, B.1
Cathignol, D.2
Muchada, R.3
-
42
-
-
0025898747
-
Comparison of changes in transit time ultrasound, esophageal Doppler, and thermodilution cardiac output after changes in preload, afterload and contractility in pigs
-
42 Wong DH, Watson T, Gordon I et al. Comparison of changes in transit time ultrasound, esophageal Doppler, and thermodilution cardiac output after changes in preload, afterload and contractility in pigs. Anesth Analg 1991; 72: 584-588.
-
(1991)
Anesth Analg
, vol.72
, pp. 584-588
-
-
Wong, D.H.1
Watson, T.2
Gordon, I.3
-
43
-
-
0000582470
-
Interaction in sheep between mean arterial pressure and cross-sectional area of the descending aorta: Implications for esophageal Doppler monitoring
-
43 List W, Gravenstein N, Banner T et al. Interaction in sheep between mean arterial pressure and cross-sectional area of the descending aorta: implications for esophageal Doppler monitoring. Anesthesiology 1987; 67: A178.
-
(1987)
Anesthesiology
, vol.67
-
-
List, W.1
Gravenstein, N.2
Banner, T.3
-
44
-
-
0024555222
-
Deviation of hemodynamic information from ultrasonic recordings of aortic diameter changes
-
44 Gustafsson D, Stale H, Bjorkman J et al. Deviation of hemodynamic information from ultrasonic recordings of aortic diameter changes. Ultrasound Med Biol 1989; 15: 189-199.
-
(1989)
Ultrasound Med Biol
, vol.15
, pp. 189-199
-
-
Gustafsson, D.1
Stale, H.2
Bjorkman, J.3
-
45
-
-
0029051998
-
Continuous haemodynamic monitoring in children: Use of transoesophageal Doppler
-
45 Murdoch IA, Marsh MJ, Tibby SM et al. Continuous haemodynamic monitoring in children: use of transoesophageal Doppler. Acta Paediatr 1995; 84: 761-764.
-
(1995)
Acta Paediatr
, vol.84
, pp. 761-764
-
-
Murdoch, I.A.1
Marsh, M.J.2
Tibby, S.M.3
|