-
1
-
-
0032495702
-
Hybrid rendering of the cervico-cranial arteries using spiral computed tomography
-
Seemann M.D., Englmeier K.H., Haubner M., et al. Hybrid rendering of the cervico-cranial arteries using spiral computed tomography. Eur. J. Med. Res. 3:1998;177-181.
-
(1998)
Eur. J. Med. Res.
, vol.3
, pp. 177-181
-
-
Seemann, M.D.1
Englmeier, K.H.2
Haubner, M.3
-
2
-
-
0032541955
-
Hybrid rendering and virtual endoscopy of the auditory and vestibular system
-
Seemann M.D., Seemann O., Englmeier K.H., Allen C.M., Haubner M., Reiser M.F. Hybrid rendering and virtual endoscopy of the auditory and vestibular system. Eur. J. Med. Res. 3:1998;515-522.
-
(1998)
Eur. J. Med. Res.
, vol.3
, pp. 515-522
-
-
Seemann, M.D.1
Seemann, O.2
Englmeier, K.H.3
Allen, C.M.4
Haubner, M.5
Reiser, M.F.6
-
3
-
-
0034735112
-
Hybrid rendering of the chest and virtual bronchoscopy
-
Seemann M.D., Seemann O., Luboldt W., Gebicke K., Prime G., Claussen C.D. Hybrid rendering of the chest and virtual bronchoscopy. Eur. J. Med. Res. 5:2000;431-437.
-
(2000)
Eur. J. Med. Res.
, vol.5
, pp. 431-437
-
-
Seemann, M.D.1
Seemann, O.2
Luboldt, W.3
Gebicke, K.4
Prime, G.5
Claussen, C.D.6
-
4
-
-
0033841694
-
Differentiation of malignant from benign solitary pulmonary lesions using chest radiography, spiral CT and HRCT
-
Seemann MD, Seemann O, Luboldt W, Bonél H, Sittek H, Dienemann H, Stäbler A. Differentiation of malignant from benign solitary pulmonary lesions using chest radiography, spiral CT and HRCT. Lung Cancer 2000;29:105-24.
-
(2000)
Lung Cancer
, vol.29
, pp. 105-124
-
-
Seemann, M.D.1
Seemann, O.2
Luboldt, W.3
Bonél, H.4
Sittek, H.5
Dienemann, H.6
Stäbler, A.7
-
5
-
-
0023182701
-
Detection of bronchial abnormalities: Comparison of CT and bronchoscopy
-
Henschke C.I., Davis S.D., Auh Y., et al. Detection of bronchial abnormalities: comparison of CT and bronchoscopy. J. Comput. Assist. Tomogr. 11:1987;432-435.
-
(1987)
J. Comput. Assist. Tomogr.
, vol.11
, pp. 432-435
-
-
Henschke, C.I.1
Davis, S.D.2
Auh, Y.3
-
6
-
-
0031647071
-
Bronchial anastomic complications in lung transplant recipients: Virtual bronchoscopy for noninvasive assessment
-
McAdams H.P., Palmer S.M., Erasmus J.J., et al. Bronchial anastomic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology. 209:1998;689-695.
-
(1998)
Radiology
, vol.209
, pp. 689-695
-
-
McAdams, H.P.1
Palmer, S.M.2
Erasmus, J.J.3
-
7
-
-
0023117897
-
Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease
-
Naidich D.P., Lee J.J., Garay S.M., McCauley D.I., Aranda C.P., Boyd A.D. Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease. AJR. 148:1987;1-7.
-
(1987)
AJR
, vol.148
, pp. 1-7
-
-
Naidich, D.P.1
Lee, J.J.2
Garay, S.M.3
McCauley, D.I.4
Aranda, C.P.5
Boyd, A.D.6
-
8
-
-
0029048445
-
Airways and lung: Correlation of CT with fiberoptic bronchoscopy
-
Naidich D.P., Harkin T.J. Airways and lung: correlation of CT with fiberoptic bronchoscopy. Radiology. 197:1995;1-12.
-
(1995)
Radiology
, vol.197
, pp. 1-12
-
-
Naidich, D.P.1
Harkin, T.J.2
-
9
-
-
0030027468
-
Helical (spiral) CT of the upper airway with three-dimensional imaging: Technique and clinical assessment
-
Zeiberg A.S., Silverman P.M., Sessions R.B., Troost T.R., Davros W.J., Zeman R.K. Helical (spiral) CT of the upper airway with three-dimensional imaging: technique and clinical assessment. AJR. 166:1996;293-299.
-
(1996)
AJR
, vol.166
, pp. 293-299
-
-
Zeiberg, A.S.1
Silverman, P.M.2
Sessions, R.B.3
Troost, T.R.4
Davros, W.J.5
Zeman, R.K.6
-
10
-
-
0029811320
-
Three-dimensional helical CT of the tracheobronchial tree: Evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic correlation
-
Kauczor H.U., Wolcke B., Fischer B., Mildenberger P., Lorenz J., Thelen M. Three-dimensional helical CT of the tracheobronchial tree: evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic correlation. AJR. 167:1996;419-424.
-
(1996)
AJR
, vol.167
, pp. 419-424
-
-
Kauczor, H.U.1
Wolcke, B.2
Fischer, B.3
Mildenberger, P.4
Lorenz, J.5
Thelen, M.6
-
12
-
-
0031132343
-
Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction: Correlation with bronchoscopy
-
Lee K.S., Yoon J.H., Kim T.K., Kim J.S., Chung M.P., Kwon O.J. Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction: correlation with bronchoscopy. RadioGraphics. 17:1997;555-567.
-
(1997)
RadioGraphics
, vol.17
, pp. 555-567
-
-
Lee, K.S.1
Yoon, J.H.2
Kim, T.K.3
Kim, J.S.4
Chung, M.P.5
Kwon, O.J.6
-
14
-
-
0028924931
-
Stenosis of the central airways: Evaluation by using helical CT with multiplanar reconstructions
-
Quint L.E., Whyte R.I., Kazerooni E.A., et al. Stenosis of the central airways: evaluation by using helical CT with multiplanar reconstructions. Radiology. 194:1995;871-877.
-
(1995)
Radiology
, vol.194
, pp. 871-877
-
-
Quint, L.E.1
Whyte, R.I.2
Kazerooni, E.A.3
-
15
-
-
0032608919
-
Evaluation of the carotid and vertebral arteries: Comparison of 3D SCTA and IA-DSA-work in progress
-
Seemann M.D., Englmeier K.H., Schuhmann D.R.G., et al. Evaluation of the carotid and vertebral arteries: comparison of 3D SCTA and IA-DSA-work in progress. Eur. Radiol. 9:1999;105-112.
-
(1999)
Eur. Radiol.
, vol.9
, pp. 105-112
-
-
Seemann, M.D.1
Englmeier, K.H.2
Schuhmann, D.R.G.3
-
16
-
-
0033252244
-
Evaluation of the middle and inner ear structures: Comparison of hybrid rendering, virtual endoscopy and axial 2D source images
-
Seemann M.D., Seemann O., Bonél H., et al. Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images. Eur. Radiol. 9:1999;1851-1858.
-
(1999)
Eur. Radiol.
, vol.9
, pp. 1851-1858
-
-
Seemann, M.D.1
Seemann, O.2
Bonél, H.3
-
17
-
-
0034077567
-
Hybrid rendering and virtual endoscopy in cochlear implants
-
Seemann M.D., Luboldt W., Haferkamp C., et al. Hybrid rendering and virtual endoscopy in cochlear implants. Fortschr. Röntgenstr. 172:2000;238-243.
-
(2000)
Fortschr. Röntgenstr.
, vol.172
, pp. 238-243
-
-
Seemann, M.D.1
Luboldt, W.2
Haferkamp, C.3
-
18
-
-
0031298043
-
Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinomas: Opportunities and limitations
-
Fleiter T., Merkle E.M., Aschoff A.J., et al. Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinomas: opportunities and limitations. AJR. 169:1997;1591-1595.
-
(1997)
AJR
, vol.169
, pp. 1591-1595
-
-
Fleiter, T.1
Merkle, E.M.2
Aschoff, A.J.3
-
19
-
-
0017158726
-
Diagnostic accuracy in lung cancer. Comparison of techniques used in association with flexible fiberoptic bronchoscopy
-
Kvale P.A., Bode F.R., Kini S. Diagnostic accuracy in lung cancer. Comparison of techniques used in association with flexible fiberoptic bronchoscopy. Chest. 69:1976;752-757.
-
(1976)
Chest
, vol.69
, pp. 752-757
-
-
Kvale, P.A.1
Bode, F.R.2
Kini, S.3
-
21
-
-
0029988087
-
Perspective volume rendering of CT and MR images: Applications for endoscopic imaging
-
Rubin G.D., Beaulieu C.F., Argiro V., et al. Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology. 199:1996;321-330.
-
(1996)
Radiology
, vol.199
, pp. 321-330
-
-
Rubin, G.D.1
Beaulieu, C.F.2
Argiro, V.3
-
22
-
-
0029787117
-
Virtual bronchoscopy: Segmentation method for real-time display
-
Summers R.M., Feng D.H., Holland S.M., Sneller M.C., Shelhamer J.H. Virtual bronchoscopy: segmentation method for real-time display. Radiology. 200:1996;857-862.
-
(1996)
Radiology
, vol.200
, pp. 857-862
-
-
Summers, R.M.1
Feng, D.H.2
Holland, S.M.3
Sneller, M.C.4
Shelhamer, J.H.5
-
23
-
-
0030024568
-
Virtual bronchoscopy. Relationships of virtual reality endobronchial simulations to actual bronchoscopic findings
-
Vining D.J., Liu K., Choplin R.H., Haponik E.F. Virtual bronchoscopy. Relationships of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest. 109:1996;549-553.
-
(1996)
Chest
, vol.109
, pp. 549-553
-
-
Vining, D.J.1
Liu, K.2
Choplin, R.H.3
Haponik, E.F.4
-
24
-
-
0026210106
-
Surface and volume rendering in three-dimensional imaging: A comparison
-
Udupa J.K., Hung H.M., Chuang K.S. Surface and volume rendering in three-dimensional imaging: a comparison. J. Digit. Imaging. 4:1991;159-168.
-
(1991)
J. Digit. Imaging
, vol.4
, pp. 159-168
-
-
Udupa, J.K.1
Hung, H.M.2
Chuang, K.S.3
-
25
-
-
0025000563
-
Three-dimensional segmentation of MR images of the head using probability and connectivity
-
Cline H.E., Lorensen W.E., Kikinis R., Jolesz F. Three-dimensional segmentation of MR images of the head using probability and connectivity. J. Comput. Assist. Tomogr. 14:1990;1037-1045.
-
(1990)
J. Comput. Assist. Tomogr.
, vol.14
, pp. 1037-1045
-
-
Cline, H.E.1
Lorensen, W.E.2
Kikinis, R.3
Jolesz, F.4
-
26
-
-
0029781840
-
Three-dimensional CT: Real-time interactive volume rendering
-
Johnson P.T., Heath D.G., Bliss D.F., Cabral B., Fishman E.K. Three-dimensional CT: real-time interactive volume rendering. AJR. 167:1996;581-583.
-
(1996)
AJR
, vol.167
, pp. 581-583
-
-
Johnson, P.T.1
Heath, D.G.2
Bliss, D.F.3
Cabral, B.4
Fishman, E.K.5
-
27
-
-
0032067494
-
Virtual bronchoscopy for directing transbronchial needle aspiration biopsy of enlarged hilar and mediastinal lymph nodes: Preliminary report
-
McAdams H.P., Kussin P., Goodman P.C. Virtual bronchoscopy for directing transbronchial needle aspiration biopsy of enlarged hilar and mediastinal lymph nodes: preliminary report. AJR. 170:1998;1361-1364.
-
(1998)
AJR
, vol.170
, pp. 1361-1364
-
-
McAdams, H.P.1
Kussin, P.2
Goodman, P.C.3
-
28
-
-
0030628794
-
Central airway stenoses: Preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients
-
Ferretti G.R., Knoplioch J., Bricault I., Brambilla C., Coulomb M. Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients. Eur. Radiol. 7:1997;854-859.
-
(1997)
Eur. Radiol.
, vol.7
, pp. 854-859
-
-
Ferretti, G.R.1
Knoplioch, J.2
Bricault, I.3
Brambilla, C.4
Coulomb, M.5
-
29
-
-
0031006983
-
3D virtual endoscopy of the upper airway: Optimization of the scan parameters in a cadaver phantom and clinical assessment
-
Rodenwaldt J., Kopka L., Roedel R., Margas A., Grabbe E. 3D virtual endoscopy of the upper airway: optimization of the scan parameters in a cadaver phantom and clinical assessment. J. Comput. Assist. Tomogr. 21:1997;405-411.
-
(1997)
J. Comput. Assist. Tomogr.
, vol.21
, pp. 405-411
-
-
Rodenwaldt, J.1
Kopka, L.2
Roedel, R.3
Margas, A.4
Grabbe, E.5
|