Volumn 71, Issue 5, 2001, Pages 1719-1720

A new off-pump technique for thoratec right ventricular assist device insertion

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD CLOTTING DISORDER; CARDIOMYOPATHY; CARDIOPULMONARY BYPASS; CASE REPORT; DEVICE; HEART RIGHT VENTRICLE; HEART VENTRICLE ARRHYTHMIA; HUMAN; KIDNEY FAILURE; LIVER DYSFUNCTION; MALE; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 0035020789     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(01)02427-4     Document Type: Article
Times cited : (9)

References (11)
  • 1
    • 0033386040 scopus 로고    scopus 로고
    • Preoperative risk factors for right ventricular failure after implantable left ventricular device insertion
    • Fukamachi K., McCarthy P.M., Smedira N.G., Vargo R.L., Starling R.C., Young J.B. Preoperative risk factors for right ventricular failure after implantable left ventricular device insertion. Ann Thorac Surg. 68:1999;2181-2184.
    • (1999) Ann Thorac Surg , vol.68 , pp. 2181-2184
    • Fukamachi, K.1    McCarthy, P.M.2    Smedira, N.G.3    Vargo, R.L.4    Starling, R.C.5    Young, J.B.6
  • 2
    • 0030250488 scopus 로고    scopus 로고
    • Pulmonary hypertension is not a risk factor for RVAD use and death after left ventricular assist system support
    • Smedira N.G., Massad M.G., Navia J., et al. Pulmonary hypertension is not a risk factor for RVAD use and death after left ventricular assist system support. ASAIO J. 42:1996;733-735.
    • (1996) ASAIO J , vol.42 , pp. 733-735
    • Smedira, N.G.1    Massad, M.G.2    Navia, J.3
  • 3
    • 0030040818 scopus 로고    scopus 로고
    • Experience with right ventricular assist devices for perioperative right-sided circulatory failure
    • Chen J.M., Levin H.R., Rose E.A., et al. Experience with right ventricular assist devices for perioperative right-sided circulatory failure. Ann Thorac Surg. 61:1996;305-310.
    • (1996) Ann Thorac Surg , vol.61 , pp. 305-310
    • Chen, J.M.1    Levin, H.R.2    Rose, E.A.3
  • 4
    • 0032417719 scopus 로고    scopus 로고
    • Alternative technique of right-sided outflow cannula insertion for right ventricular support
    • Dewey T.M., Chen J.M., Spanier T.B., Oz M.C. Alternative technique of right-sided outflow cannula insertion for right ventricular support. Ann Thorac Surg. 66:1998;1829-1830.
    • (1998) Ann Thorac Surg , vol.66 , pp. 1829-1830
    • Dewey, T.M.1    Chen, J.M.2    Spanier, T.B.3    Oz, M.C.4
  • 5
    • 0032744837 scopus 로고    scopus 로고
    • New technique for the outflow cannulation of right ventricular assist device
    • Minami K., Bonkohara Y., Arusoglu L., El-Banayosy A., Korfer R. New technique for the outflow cannulation of right ventricular assist device. Ann Thorac Surg. 68:1999;1092-1093.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1092-1093
    • Minami, K.1    Bonkohara, Y.2    Arusoglu, L.3    El-Banayosy, A.4    Korfer, R.5
  • 6
    • 0027310437 scopus 로고
    • The platelet function defect of cardiopulmonary bypass
    • Kestin A.S., Valeri C.R., Khuri S.F., et al. The platelet function defect of cardiopulmonary bypass. Blood. 82:1993;107-112.
    • (1993) Blood , vol.82 , pp. 107-112
    • Kestin, A.S.1    Valeri, C.R.2    Khuri, S.F.3
  • 7
    • 0005171028 scopus 로고
    • Renal function and fluid balance with cardiopulmonary bypass
    • G.P. Gravlee, R.F. Davis, & J.R. Utley. Baltimore: Williams & Wilkins
    • Utley J.R. Renal function and fluid balance with cardiopulmonary bypass. Gravlee G.P., Davis R.F., Utley J.R. Cardiopulmonary bypass. 1993;488 Williams & Wilkins, Baltimore.
    • (1993) Cardiopulmonary Bypass , pp. 488
    • Utley, J.R.1
  • 8
    • 0022647711 scopus 로고
    • Heterotopic artificial heart as bridge to cardiac transplantation
    • Carpentier A., Brugger J.P., Brethier B., et al. Heterotopic artificial heart as bridge to cardiac transplantation. Lancet. 12:1986;97-98.
    • (1986) Lancet , vol.12 , pp. 97-98
    • Carpentier, A.1    Brugger, J.P.2    Brethier, B.3
  • 10
    • 0028789133 scopus 로고
    • Left atrial or ventricular cannulation beyond 30 days for a Thoratec ventricular assist device
    • Holman W.L., Bourge R.C., Murrah C.P., et al. Left atrial or ventricular cannulation beyond 30 days for a Thoratec ventricular assist device. ASAIO J. 41:1995;517-522.
    • (1995) ASAIO J , vol.41 , pp. 517-522
    • Holman, W.L.1    Bourge, R.C.2    Murrah, C.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.