Volumn 94, Issue 5, 2001, Pages 729-731

A comparison of tracheal tube tip designs on the passage of an endotracheal tube during oral fiberoptic intubation

Author keywords

[No Author keywords available]

Indexed keywords

POLYVINYLCHLORIDE; SILASTIC;

EID: 0035001714     PISSN: 00033022     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000542-200105000-00007     Document Type: Article
Times cited : (52)

References (12)
  • 1
    • 0014102275 scopus 로고
    • A fibreoptic scope used for nasal intubation
    • Murphy P: A fibreoptic scope used for nasal intubation. Anaesthesia 1967; 22:489-91
    • (1967) Anaesthesia , vol.22 , pp. 489-491
    • Murphy, P.1
  • 3
    • 0023937579 scopus 로고
    • Teaching guided fibreoptic nasotracheal intubation. An assessment of an anaesthetic technique to aid training
    • Coe PA, King TA, Towey RM: Teaching guided fibreoptic nasotracheal intubation. An assessment of an anaesthetic technique to aid training. Anaesthesia 1988; 43:410-3
    • (1988) Anaesthesia , vol.43 , pp. 410-413
    • Coe, P.A.1    King, T.A.2    Towey, R.M.3
  • 4
    • 0029080664 scopus 로고
    • Comparison between two fibrescopes with different diameter insertion cords for fibreoptic intubation
    • Hakala P, Randell T: Comparison between two fibrescopes with different diameter insertion cords for fibreoptic intubation. Anaesthesia 1995; 50:735-7
    • (1995) Anaesthesia , vol.50 , pp. 735-737
    • Hakala, P.1    Randell, T.2
  • 5
    • 0026538657 scopus 로고
    • Easier Fiberoptic intubations
    • Marsh NJ: Easier Fiberoptic intubations. ANESTHESIOIOGY 1992; 76:860-1
    • (1992) Anesthesioiogy , vol.76 , pp. 860-861
    • Marsh, N.J.1
  • 6
    • 0026642443 scopus 로고
    • When the endotracheal tube will not pass over the flexible fiberoptic bronchoscope
    • Calder I: When the endotracheal tube will not pass over the flexible fiberoptic bronchoscope (letter). ANESTHESIOLOGY 1992; 77:398
    • (1992) Anesthesiology , vol.77 , pp. 398
    • Calder, I.1
  • 7
    • 0027275548 scopus 로고
    • Fibreoptic intubation. Influence of tracheal tube tip design
    • Jones HE, Pearce AC, Moore P: Fibreoptic intubation. Influence of tracheal tube tip design. Anaesthesia 1993; 48:672-4
    • (1993) Anaesthesia , vol.48 , pp. 672-674
    • Jones, H.E.1    Pearce, A.C.2    Moore, P.3
  • 8
    • 0342387707 scopus 로고
    • Difficult intubation
    • Cossham PS: Difficult intubation. Br J Anaesth 1985; 55:187-8
    • (1985) Br J Anaesth , vol.55 , pp. 187-188
    • Cossham, P.S.1
  • 9
    • 0025029671 scopus 로고
    • Successful difficult intubation. Tracheal tube placement over a gum-elastic bougie
    • Dogra S, Falconer R, Latto IP: Successful difficult intubation. Tracheal tube placement over a gum-elastic bougie. Anaesthesia 1990; 45:774-6
    • (1990) Anaesthesia , vol.45 , pp. 774-776
    • Dogra, S.1    Falconer, R.2    Latto, I.P.3
  • 10
    • 0032706731 scopus 로고    scopus 로고
    • A comparison of two silicone-reinforced tracheal tubes with different bevels for use with the intubating laryngeal mask
    • Murashima K, Fukutome T, Brimaombe J: A comparison of two silicone-reinforced tracheal tubes with different bevels for use with the intubating laryngeal mask. Anaesthesia 1999; 54:1198-200
    • (1999) Anaesthesia , vol.54 , pp. 1198-1200
    • Murashima, K.1    Fukutome, T.2    Brimaombe, J.3
  • 12
    • 0030840388 scopus 로고    scopus 로고
    • The intubating laryngeal mask: I. Development of a new device for intubation of the trachea
    • Brain AIJ, Verghese C, Addy EV, Kapila A: The intubating laryngeal mask: I. Development of a new device for intubation of the trachea. Br J Anaesth 1997; 79:699-703
    • (1997) Br J Anaesth , vol.79 , pp. 699-703
    • Brain, A.I.J.1    Verghese, C.2    Addy, E.V.3    Kapila, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.