메뉴 건너뛰기




Volumn 115, Issue 6, 2001, Pages 894-898

Reduction of the platelet review rate using the two-dimensional platelet method

Author keywords

Flow cytometry; Laboratory review rate; Light scatter; Optical platelet analysis; Platelet count; RBC interference

Indexed keywords

ACCURACY; ARTICLE; BLEEDING DISORDER; BLOOD ANALYSIS; CANCER; CELL DIFFERENTIATION; CELL SIZE; ERYTHROCYTE; HUMAN; LEUKEMIA; PRIORITY JOURNAL; THROMBOCYTE ANOMALY; THROMBOCYTE COUNT;

EID: 0035001115     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/C563-49VA-JYDU-LEJG     Document Type: Article
Times cited : (15)

References (6)
  • 1
    • 0026090053 scopus 로고
    • White blood cell differentials as performed by the Technicon H*1: Evaluation and implementation in a tertiary care hospital
    • Miers M, Exton M, Hurlbut T, et al. White blood cell differentials as performed by the Technicon H*1: evaluation and implementation in a tertiary care hospital. Lab Med. 1991;22:99-106.
    • (1991) Lab Med. , vol.22 , pp. 99-106
    • Miers, M.1    Exton, M.2    Hurlbut, T.3
  • 2
    • 0034520776 scopus 로고    scopus 로고
    • Improved platelet counting using two-dimensional laser light scatter
    • Kunicka JE, Fischer G, Murphy J, et al. Improved platelet counting using two-dimensional laser light scatter. Am J Clin Pathol. 2000;114:283-289.
    • (2000) Am J Clin Pathol. , vol.114 , pp. 283-289
    • Kunicka, J.E.1    Fischer, G.2    Murphy, J.3
  • 3
    • 0034057290 scopus 로고    scopus 로고
    • Immunoplatelet counting: A proposed new reference procedure
    • Harrison P, Horton A, Grant D, et al. Immunoplatelet counting: a proposed new reference procedure. Br J Haematol. 2000;108:228-235.
    • (2000) Br J Haematol. , vol.108 , pp. 228-235
    • Harrison, P.1    Horton, A.2    Grant, D.3
  • 4
    • 0032928682 scopus 로고    scopus 로고
    • Automated counting of platelets on the ADVIA 120 analyzer
    • Stanworth SJ, Denton K, Monteath J, et al. Automated counting of platelets on the ADVIA 120 analyzer. Clin Lab Haematol. 1999;21:113-117.
    • (1999) Clin Lab Haematol. , vol.21 , pp. 113-117
    • Stanworth, S.J.1    Denton, K.2    Monteath, J.3
  • 5
    • 84975646227 scopus 로고
    • Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration
    • Tycko DH, Metz MH, Epstein EA, et al. Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. Appl Optics. 1985;24:1355-1365.
    • (1985) Appl Optics , vol.24 , pp. 1355-1365
    • Tycko, D.H.1    Metz, M.H.2    Epstein, E.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.