메뉴 건너뛰기




Volumn 45, Issue 2, 2001, Pages 205-210

Dose perturbation by air cavities in megavoltage photon beams: Implications for cavity surface doses

Author keywords

Dosimetry calculations; Interface doses; Monte Carlo; Radiotherapy

Indexed keywords

ARTICLE; DOSE CALCULATION; DOSE RESPONSE; DOSIMETRY; HUMAN; MEGAVOLTAGE RADIOTHERAPY; PRIORITY JOURNAL; PROSTATE; RADIATION DOSE; RECTUM; SIMULATION; SYSTEM ANALYSIS;

EID: 0035000561     PISSN: 00048461     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1440-1673.2001.00900.x     Document Type: Article
Times cited : (7)

References (10)
  • 3
    • 0027969177 scopus 로고
    • Air cavity effects on the radiation dose to the larynx using Co-60, 6 MV and 10 MV photon beams
    • 3. Niroomand-Rad A, Harter KW, Thobejane S, Bertrand K, Air cavity effects on the radiation dose to the larynx using Co-60, 6 MV and 10 MV photon beams, Int J Radiat Oncol Biol Phys 1994; 29: 1139-46.
    • (1994) Int J Radiat Oncol Biol Phys , vol.29 , pp. 1139-1146
    • Niroomand-Rad, A.1    Harter, K.W.2    Thobejane, S.3    Bertrand, K.4
  • 4
    • 0030300207 scopus 로고    scopus 로고
    • The effects of air cavities on X-ray dose distributions at 6 and 25 MV
    • 4. Wong TP, Kan WK, Law M. The effects of air cavities on X-ray dose distributions at 6 and 25 MV. Aust Phys Eng Sci Med 1996; 19: 237-47.
    • (1996) Aust Phys Eng Sci Med , vol.19 , pp. 237-247
    • Wong, T.P.1    Kan, W.K.2    Law, M.3
  • 5
    • 0031929807 scopus 로고    scopus 로고
    • The effect of nasopharyngeal air cavity on X-ray interface doses
    • 5. Kan WK, Wu PM, Leung HT et al. The effect of nasopharyngeal air cavity on X-ray interface doses. Phys Med Biol 1998; 43: 529-37.
    • (1998) Phys Med Biol , vol.43 , pp. 529-537
    • Kan, W.K.1    Wu, P.M.2    Leung, H.T.3
  • 8
    • 0003620648 scopus 로고
    • Stanford Linear Accelerator Centre Report 265. Stanford University, Stanford
    • 8. Nelson WR, Hirayama H, Rogers DWO. The EGS4 Code System. Stanford Linear Accelerator Centre Report 265. Stanford University, Stanford, 1985.
    • (1985) The EGS4 Code System
    • Nelson, W.R.1    Hirayama, H.2    Rogers, D.W.O.3
  • 9
    • 0025486688 scopus 로고
    • Using EGS4 Monte Carlo in medical radiation physics
    • 9. Murray D, Using EGS4 Monte Carlo in medical radiation physics. Aust Phys Eng Sci Med 1990; 13: 132-47.
    • (1990) Aust Phys Eng Sci Med , vol.13 , pp. 132-147
    • Murray, D.1
  • 10
    • 0030905738 scopus 로고    scopus 로고
    • Predicting late rectal complications following prostate conformal radiotherapy using biologically effective doses and normalized dose-surface histograms
    • 10. MacKay RI, Hendry JH, Moore CJ, Williams PC, Read G. Predicting late rectal complications following prostate conformal radiotherapy using biologically effective doses and normalized dose-surface histograms. Br J Radiol 1997; 70: 517-26.
    • (1997) Br J Radiol , vol.70 , pp. 517-526
    • MacKay, R.I.1    Hendry, J.H.2    Moore, C.J.3    Williams, P.C.4    Read, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.