Volumn 22, Issue 2, 2001, Pages 267-286

Cardiopulmonary monitoring at home: The CHIME monitor

(15)  Neuman, Michael R a,j   Watson, Herman b   Mendenhall, Rebecca S c   Zoldak, John T a   Di Fiore, Juliann M d   Peucker, Mark e   Baird, Terry M d   Crowell, David H f   Hoppenbrouwers, Toke T g   Hufford, David h   Hunt, Carl E h   Corwin, Michael J e   Tinsley, Larry R f   Weese Mayer, Debra E i   Sackner, Marvin A b  


Author keywords

Collaborative Home Infant Monitoring Evaluation (CHIME); Inductance plethysmograph; Infant apnoea monitoring; Patient monitoring at home

Indexed keywords

ELECTROCARDIOGRAPHY; HEART; NONINVASIVE MEDICAL PROCEDURES; OXIMETERS; PATIENT MONITORING;

EID: 0034997184     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/22/2/301     Document Type: Article
Times cited : (34)

References (11)
  • 1
    • 0027672856 scopus 로고
    • Measurement of breath amplitudes: Comparison of three noninvasive respiratory monitors to integrated pneumotachograph
    • Adams J A, Zabaleta I A, Stroh D and Sackner M A 1993 Measurement of breath amplitudes: comparison of three noninvasive respiratory monitors to integrated pneumotachograph Pediatr. Pulmonol. 16 254-8
    • (1993) Pediatr. Pulmonol. , vol.16 , pp. 254-258
    • Adams, J.A.1    Zabaleta, I.A.2    Stroh, D.3    Sackner, M.A.4
  • 2
    • 0025929579 scopus 로고
    • Effect of infant position on breath amplitude measured by transthoracic impedance and strain gauges
    • Baird TM and Neuman M R 1991 Effect of infant position on breath amplitude measured by transthoracic impedance and strain gauges Pediatr. Pulmonol. 10 52-6
    • (1991) Pediatr. Pulmonol. , vol.10 , pp. 52-56
    • Baird, T.M.1    Neuman, M.R.2
  • 3
    • 0030792048 scopus 로고    scopus 로고
    • Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmogiaphy
    • Brooks L J, Di Fiore J M, Martin R J and the CHIME Study Group 1997 Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmogiaphy Pediatr. Pulmonol. 23 429-33
    • (1997) Pediatr. Pulmonol. , vol.23 , pp. 429-433
    • Brooks, L.J.1    Di Fiore, J.M.2    Martin, R.J.3
  • 4
    • 0023639535 scopus 로고
    • Comparison of respiratory plethysmography and thoracic impedance for apnoea monitoring
    • Brouillette R T, Morrow A S, Weese-Mayer D E and Hunt C E 1987 Comparison of respiratory plethysmography and thoracic impedance for apnoea monitoring J. Pediatr. 111 377-83
    • (1987) J. Pediatr. , vol.111 , pp. 377-383
    • Brouillette, R.T.1    Morrow, A.S.2    Weese-Mayer, D.E.3    Hunt, C.E.4
  • 7
    • 0033510527 scopus 로고    scopus 로고
    • Longitudinal assessment of haemoglobin oxygen saturation in healthy infants during the first 6 months of age
    • Hunt C E et al and the CHIME Study Group 1999 Longitudinal assessment of haemoglobin oxygen saturation in healthy infants during the first 6 months of age J. Pediatr. 134 580-6
    • (1999) J. Pediatr. , vol.134 , pp. 580-586
    • Hunt, C.E.1
  • 8
    • 0343635961 scopus 로고
    • Infant apnea and home monitoring
    • (Bethesda, MD: National Institutes of Health) NIH 87-2905
    • Little G A (ed) 1987 Infant apnea and home monitoring Report of a Consensus Development Conference (Bethesda, MD: National Institutes of Health) NIH 87-2905
    • (1987) Report of a Consensus Development Conference
    • Little, G.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.