메뉴 건너뛰기




Volumn 22, Issue 5, 2001, Pages 547-552

Is the depth correction using the geometric mean really necessary in a Tcm-DMSA scan in the paediatric population?

Author keywords

Depth correction; Differential renal function; DMSA scan; Geometric mean; Paediatric population

Indexed keywords

SUCCIMER TC 99M;

EID: 0034996620     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/00006231-200105000-00013     Document Type: Article
Times cited : (10)

References (17)
  • 1
    • 0033009859 scopus 로고    scopus 로고
    • Consensus on renal cortical scintigraphy in children with urinary tract infection.
    • Piepsz A, Blaufox MD, Gordon I et al. Consensus on renal cortical scintigraphy in children with urinary tract infection. Semin Nucl Med 1999; 29: 160-174.
    • (1999) Semin Nucl Med , vol.29 , pp. 160-174
    • Piepsz, A.1    Blaufox, M.D.2    Gordon, I.3
  • 3
    • 0023637194 scopus 로고
    • Measurement of relative renal function. A comparison of methods and assessment of reproducibility.
    • Nimmo MJ, Merrick MV, Allan PL. Measurement of relative renal function. A comparison of methods and assessment of reproducibility. Br J Radiol 1987; 60: 861-864.
    • (1987) Br J Radiol , vol.60 , pp. 861-864
    • Nimmo, M.J.1    Merrick, M.V.2    Allan, P.L.3
  • 4
    • 0026693945 scopus 로고
    • Kidney depth measured by using Tc-99m DMSA. Comparison with CAT scan: Review of 50 measurements.
    • Hambye AS, Merlo P, Hermans J, Bodart F, Beauduin M, Gilbeau JP. Kidney depth measured by using Tc-99m DMSA. Comparison with CAT scan: review of 50 measurements. Nucl Med Commun 1992; 13: 488-493.
    • (1992) Nucl Med Commun , vol.13 , pp. 488-493
    • Hambye, A.S.1    Merlo, P.2    Hermans, J.3    Bodart, F.4    Beauduin, M.5    Gilbeau, J.P.6
  • 6
    • 0031885991 scopus 로고    scopus 로고
    • Estimation and relevance of depth correction in paediatric renal studies.
    • Lythgoe MF, Gradwell MJ, Evans K, Gordon I. Estimation and relevance of depth correction in paediatric renal studies. Eur J Nucl Med 1998; 25: 115-119.
    • (1998) Eur J Nucl Med , vol.25 , pp. 115-119
    • Lythgoe, M.F.1    Gradwell, M.J.2    Evans, K.3    Gordon, I.4
  • 7
    • 0025183556 scopus 로고
    • Influence of kidney depth on the renographic estimation of relative renal function.
    • Cosgriff P, Brown H. Influence of kidney depth on the renographic estimation of relative renal function. J Nucl Med 1990; 31: 1576-1577.
    • (1990) J Nucl Med , vol.31 , pp. 1576-1577
    • Cosgriff, P.1    Brown, H.2
  • 9
    • 0017823115 scopus 로고
    • Correlation of differential renal function determination by Tc-99m-DMSA imaging and ureteral catheterisation.
    • Born ML, Grove RB, Jones JP et al. Correlation of differential renal function determination by Tc-99m-DMSA imaging and ureteral catheterisation. J Nucl Med 1978; 19: 721.
    • (1978) J Nucl Med , vol.19 , pp. 721
    • Born, M.L.1    Grove, R.B.2    Jones, J.P.3
  • 10
    • 0019412080 scopus 로고
    • Radionuclide measurement of differential glomerular filtration rate.
    • Powers TA, Stone WJ, Grove B et al. Radionuclide measurement of differential glomerular filtration rate. Invest Radiol 1981; 16: 59-64.
    • (1981) Invest Radiol , vol.16 , pp. 59-64
    • Powers, T.A.1    Stone, W.J.2    Grove, B.3
  • 11
    • 0025270419 scopus 로고
    • Measurement of skin-to-kidney distance in children: Implications for quantitative renography.
    • Maneval DC, Magill HL, Cypess AM, Rodman JH. Measurement of skin-to-kidney distance in children: implications for quantitative renography. J Nucl Med 1990; 31: 287-291.
    • (1990) J Nucl Med , vol.31 , pp. 287-291
    • Maneval, D.C.1    Magill, H.L.2    Cypess, A.M.3    Rodman, J.H.4
  • 12
    • 0023684657 scopus 로고
    • Avoidance of errors related to renal depth during radionuclide evaluation of renal perfusion.
    • Conrad GR, Wesolowski CA. Avoidance of errors related to renal depth during radionuclide evaluation of renal perfusion. Clin Nucl Med 1988; 13: 721-726.
    • (1988) Clin Nucl Med , vol.13 , pp. 721-726
    • Conrad, G.R.1    Wesolowski, C.A.2
  • 13
    • 0023548403 scopus 로고
    • Scintigraphy of kidneys located at different depths: The geometric mean method for determination of differential renal function.
    • Hartling OJ, Marving J, Munck O. Scintigraphy of kidneys located at different depths: the geometric mean method for determination of differential renal function. Clin Nucl Med 1987; 12: 956-957.
    • (1987) Clin Nucl Med , vol.12 , pp. 956-957
    • Hartling, O.J.1    Marving, J.2    Munck, O.3
  • 16
    • 85026150817 scopus 로고
    • Influence on the radiorenogram of variation in skin to kidney distance and the clinical importance hereof. In: Winkel K, Blaufox MD, Funck-Bretano J-L, eds. Proceedings of the international symposium on radionuclides in nephrology.
    • Tonnesen KH, Munck O, Hald T, Mogensen P, Wolf H. Influence on the radiorenogram of variation in skin to kidney distance and the clinical importance hereof. In: Winkel K, Blaufox MD, Funck-Bretano J-L, eds. Proceedings of the international symposium on radionuclides in nephrology. Stuttgart: Thieme, 1974: 79-86.
    • (1974) Stuttgart: Thieme , vol.79 , pp. 86
    • Tonnesen, K.H.1    Munck, O.2    Hald, T.3    Mogensen, P.4    Wolf, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.